• 제목/요약/키워드: Prevention Device

검색결과 475건 처리시간 0.028초

밴드형 첨족예방기구의 효과와 유용성 (The Effects of the Band Type Foot Drop Device)

  • 강현숙;김원옥;이혜숙
    • 기본간호학회지
    • /
    • 제7권3호
    • /
    • pp.391-400
    • /
    • 2000
  • A long-term bed rest results in an inevitable foot drop. Yet preventive device such as a foot board and high-neck tennis shoes, are not widely used. This study was conducted to compare the effects of a pillow-type foot board with that of the band-type device. The band-type device of a resonable price is designed for an effective prevention of foot drop, and the convenience for it use. Among the non-equivalent control group design, foot drop preventive effects, usefulness of the device, as well as its cost effectiveness were examined. The study was carried out for four months from December 1999, and its subject had been patients and nurses of two intensive care units at K medical center in Seoul. According to the study purpose, the data collected were analyzed by $x^2-test$ and t-test. The results are as follow : 1. The ROM of ankle joint is promoted in the experimental group with a band-type device comparing the control group with a pillow type one. Dorsiflexion is particularly increased in the experimental group as compared with the control group, while planterflexion hardly shows any change. 2. The usefulness score of the experimental group nurses using the band-type device (23.97) is higher than that of the control group nurses (18.88). 3. In an aspect of the unit production cost, band-type devices are low-priced compare with pillow-type or other foot board (wooden) or high-neck tennis shoes. In summary, the newly developed band-type device is both useful and preventive for a foot drop. It is also desirable regarding to the production cost and the cost effectiveness. This fact proves that the new anti-foot drop device could be practical both for clinical care and home care. Yet the results were obtained by some subjects, it should be used after a further examination. More effective nursing intervention could be observed throughout general studies, including proper positioning and foot and ankle exercises which are the important variables of the foot drop prevention.

  • PDF

산업용 위험기계 및 기구관련 산재예방 정책 연구 (Safety Policies on Prevention of Industrial Accidents Associated with Industrial Machines and Devices)

  • 최기흥
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.26-33
    • /
    • 2015
  • This study suggests systematic procedures to improve safety policies on prevention of industrial accidents associated with industrial machines and devices. Specifically, new method of cause analysis of industrial accidents associated with industrial machines and devices is suggested and the related accident data are re-analyzed. Effectiveness of direct safety regulations such as safety certification, self-declaration of conformity, safety device regulation and safety inspection of industrial machines and devices are also analyzed. Based on those analysis results, transition from the current user-oriented safety device regulation to more balanced direct regulations on both manufacturer and user is suggested. Together with severity and frequency of industrial accidents, unit severity and unit frequency need to be taken into account to further assess the risk associated with a particular industrial machine or device. Balance between safety regulations will be realized by proper adjustment of lists of safety certification and inspection, and certification and inspection standards. This will also guarantee the maximum benefit over cost in such safety regulations.

미아방지용 스마트 디바이스를 위한 전력 관리 시스템 구현에 관한 연구 (Implementation of Power Management System for Smart device for the prevention of missing child)

  • 김영길;강석범
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.493-496
    • /
    • 2007
  • 최근 유비쿼터스 시대에 진입하면서 PDA,PMP, Smart Phone 등의 휴대형 정보기기의 보급으로 임베디드 시스템의 기능이 다양해지고 멀티미디어 기능이 강화됨에 따라 시스템이 처리해야할 정보의 양도 늘어나고 있다. 이에 따라 시스템은 대용량의 전력 공급이 필요하게 되었다. 그러므로 Battery라는 제한적인 에너지원을 사용하는 휴대형기기에서 전력 관리는 중요한 이슈가 되고 있다. 본 논문에서는 미아방지용 스마트 디바이스에 최적화된 젼력 관리 솔루션을 제공하는데에 초점을 맞추었다. CPU는 ARM9 Core를 사용하고 Windows CE 5.0을 Porting 하였다.

  • PDF

Seismic performance evaluation of a steel slit damper for retrofit of structures on soft soil

  • Mahammad Seddiq Eskandari Nasab;Jinkoo Kim;Tae-Sang Ahn
    • Steel and Composite Structures
    • /
    • 제51권1호
    • /
    • pp.93-101
    • /
    • 2024
  • This paper presents an experimental and analytical study on a steel slit damper designed as an energy dissipative device for earthquake protection of structures considering soil-structure interaction. The steel slit damper is made of a steel plate with a number of slits cut out of it. The slit damper has an advantage as a seismic energy dissipation device in that the stiffness and the yield force of the damper can be easily controlled by changing the number and size of the vertical strips. Cyclic loading tests of the slit damper are carried out to verify its energy dissipation capability, and an analytical model is developed validated based on the test results. The seismic performance of a case study building is then assessed using nonlinear dynamic analysis with and without soil-structure interaction. The soil-structure system turns out to show larger seismic responses and thus seismic retrofit is required to satisfy a predefined performance limit state. The developed slit dampers are employed as a seismic energy dissipation device for retrofitting the case study structure taking into account the soil-structure interaction. The seismic performance evaluation of the model structure shows that the device works stably and dissipates significant amount of seismic energy during earthquake excitations, and is effective in lowering the seismic response of structures standing on soft soil.

웨어러블 장치를 이용한 건설사고 예방 시스템 개발 기초 연구 (Basic Study on Safety Accident Prevention System Development Using Wearable Device)

  • 류한국;강진우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.55-56
    • /
    • 2018
  • In order to reduce the risk of accidents, we proposed a construction safety management system combined with wearable device and LoRa (Low-Range Wireless Network) communication method to apply the usefulness of Internet (IoT) technology which means "everything connected". to construction safety management Management system. The proposed wearable safety device is a device that relays information exchange between wearable safety device and safety management server by LoRa wireless communication method. The safety management server can store workers bio-data and perform big data analysis. If a risk factor is determined from the analysis result, a warning is sent to the wearable safety device and the manager's application. The goal of this system is to prevent construction workers from entering the dangerous area that is not suitable for work, and to prevent safety accidents caused by human cause by detecting abnormal condition during work.

  • PDF

미아 방지용 스마트 디바이스 구현에 관한 연구 (Smart device research for the prevention of missing child)

  • 안종찬;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.437-440
    • /
    • 2007
  • 최근 임베디드 시스템 디바이스 분야가 많은 발전을 이루었다. MP3, 디지털 시계같은 휴대형 디바이스에서부터 공장 제어기계난 핵발전소 제어 시스템과 같은 큰 규모의 시스템까지 그 범위가 광대하다. 본 논문은 임베디드 휴대형 장치를 구현하는 데 초점을 두었으며 이를 이용하여 아파트 공공단지 내 유아 유괴 방지 시스템에 적용시켜보았다. ARM9 core를 적용한 s3c2440을 이용한 임베디드 하드웨어 플랫폼으로 구현하였고 이 위에 WindowsCE OS를 사용하여 영상의 입력과 처리 그리고 전송의 멀티태스킹 작업을 가능하게 하였다. 그 외 GPS정보를 이용한 위치 추적, 카메라와 마이크의 실시간 영상 소리 데이터를 이용한 사용자의 상태확인 등의 다른 어플리케이션과 서비스를 구현할 수 있도록 하였다. 본 논문은 스마트 디바이스에서 받은 영상을 WLAN으로 호스트PC에 전송을 하는 시스템에 초점을 맞추었다.

  • PDF

전등 부하 및 전동기 부하시 전기화재예방 제어장치의 동작 특성에 관한 연구 (A Study on Dynamic Characteristics of Electrical Fire Prevention Control Devices with a lamp and a motor load)

  • 이상호;오홍석
    • 한국산업융합학회 논문집
    • /
    • 제5권3호
    • /
    • pp.255-260
    • /
    • 2002
  • Recently, the occurrences of electrical fire have been suppressed by an earth leakage breaker(ELB), a no fuse breaker(NFB) and a fuse in case of an earth leakage, a short circuit and an over current. But it is impossible for the ELB to break the circuit in the case of the failure of pressure contacts on connecting points and the momentary short circuit. Therefore, it is require to study the constructive problem of the ELB. In this paper, we have developed the auxiliary control device, electrical fire prevention control device(EFPCD), of the ELB. And we have tested the operation characteristics of the ELB according to the load(R, L) As a result of this experiment, we could prevent the electrical fire due to the spark and the overheat occurring in the failure of pressure contacts on connecting points and the momentary short circuit.

  • PDF

저압배선 선로의 단선사고 발생시 전기화재예방 제어장치(EFPCD)의 동작 특성에 관한 연구 (A Study on Dynamic Characteristics of EFPCD for Conductor Breaks in Low Voltage Wiring)

  • 이상호;신미영;이경호
    • 한국화재소방학회논문지
    • /
    • 제18권3호
    • /
    • pp.103-107
    • /
    • 2004
  • 현재 저압 배선 선로에 있어서 단선 사고로 인해 발생하는 스파크와 열은 전기화재의 주요 원인이 되고 있다. 또한 단선사고 시 발생하는 전류는 일종의 써지(Surge) 전류가 되어 통신, 가전제품, 컴퓨터 그리고 각종 측정기기의 소손 및 고장을 일으키며, 특히 단선사고는 다양한 안전점검 시 발견이 매우 어려운 실정이다. 따라서, 본 논문에서는 누전차단기(Earth Leakage Breaker)의 보조 제어장치, 즉 전기화재예방 제어장치(Electrical Fire Prevention Control Device)를 개발하여, 상기 단선사고 시 누전차단기의 동작신뢰성을 제고시켜, 스파크 및 열에 의한 전기화재를 예방하고자 한다.

고정밀 전류센서를 이용한 이중 차단용 전기화재 방재장치에 관한 연구 (A Study on Electrical Fire Disaster Prevention Device used in Double Circuit Break)

  • 박동필;곽동걸;정도영;김춘삼;신호준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2102-2103
    • /
    • 2008
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device(RCD) of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms](KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this paper is proposed to a electrical fire disaster prevention device(EFDPD) for a RCD trip or a self circuit-breaking function on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

  • PDF

화재사례 및 재현실험을 통한 온도조절장치 고장 및 오동작으로 인한 전자제품 화재 메커니즘 분석 (A Study on the Analysis of Fire Mechanisms in Electronic Products due to Failure and Malfunction of Thermostats Through Fire Cases and Reproduction Experiments)

  • 이정일;임종화
    • 대한안전경영과학회지
    • /
    • 제26권1호
    • /
    • pp.31-38
    • /
    • 2024
  • In this paper, as there are many cases of fires occurring due to the failure or inoperability of the thermostat of electronic products, the purpose is to test and analyze the risks and probabilities through fire cases and reproduction experiments, and suggest countermeasures. Among electronic products, water purifiers are composed of a refrigerant system with a compressor to make cold water, a heating device to make hot water, and an electric device used as an energy source. Due to the nature of the water purifier manufacturing, these devices are subject to a lot of moisture and dust. etc. exist in large quantities and use electrical energy, so there is a possibility of fire due to short circuit in the wire, electrical abnormal overheating (tracking phenomenon) in the thermostat, electronic board, starting relay, etc., and overheating of the heating device (Band Heater). there is. Therefore, in order to prevent fires from these devices, a system to remove foreign substances inside the water purifier is necessary, the use of heat-resistant (fire-resistant) wires for electrical devices is essential, and the use of non-combustible materials (semi-combustible materials) for each part is necessary to prevent fire. The risk must be eliminated through prevention and combustion expansion prevention devices.