• 제목/요약/키워드: Prestressing

검색결과 554건 처리시간 0.032초

커버플레이트를 이용한 다단계 온도프리스트레싱으로 보강된 합성보의 하중-저항성능 분석 (Load-Carrying Capacity Evaluation of the Composite Beam Strengthened by Multi-Stepwise Thermal Prestressing Method Using Cover-Plate)

  • 안진희;정치영;최규태;김상효
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권4호통권56호
    • /
    • pp.159-169
    • /
    • 2009
  • 본 연구는 다단계 온도프리스트레싱 공법으로 보강된 합성보의 하중재하 실험 및 구조해석을 통하여 온도프리스트레싱 공법의 프리스트레스 도입효과와 단면증가효과를 평가하였다. 연구결과 온도프리스트레싱을 이용한 합성보의 보강공법은 온도프리스트레싱에 의한 프리스트레스 도입 뿐 아니라 커버플레이트의 설치에 의한 단면증가로 합성보의 처짐 또한 감소시킬 수 있으므로 합성보의 효율적인 보강공법으로 적용이 가능할 것이다.

Behavior and stress check of concrete box girders strengthened by external prestressing

  • Zhang, Yu;Xu, Dong;Liu, Chao
    • Computers and Concrete
    • /
    • 제22권2호
    • /
    • pp.133-142
    • /
    • 2018
  • The deterioration of existing bridges has become a major problem around the world. In the paper, a new model and an associated stress checking method are proposed for concrete box girders strengthened by external prestressing. The new model called the spatial grid model can analyze all the spatial behaviors clearly by transforming the box girder into discrete orthogonal grids which are equivalent to plate elements. Then the three-layer stresses are employed as the stress checking indices to evaluate the stress state of the plate elements. The initial stress check before strengthening reveals the cracked and potential cracking areas for existing bridges, making the strengthening design more targeted and scientific; the subsequent stress check after strengthening evaluates the strengthening effect and ensures safety. A deficient bridge is selected as the practical example, verifying the accuracy and applicability of the proposed model and stress checking method. The results show that principal stresses in the middle layer of plate elements reflect the main effects of external prestressing and thus are the key stress checking indices for strengthening. Moreover, principal stresses check should be conducted in all parts of the strengthened structure not only in the webs. As for the local effects of external prestressing especially in the areas near anchorage and deviator, normal stresses check in the outer and inner layers dominates and local strengthening measures should be taken if necessary.

Effects of Stressed and Unstressed Reinforcements on Prestressed Concrete Members with Unbonded Tendons

  • Moon, Jeong-Ho;Shin, Kyung-Jae;Lim, Jae-Hyung;Lee, Sun-Hwa
    • KCI Concrete Journal
    • /
    • 제12권1호
    • /
    • pp.131-138
    • /
    • 2000
  • The research purpose of this paper is to investigate the influential Parameters on the unbonded tendon stress. The parameters were the reinforcing ratio, the prestressing ratio, and the loading type. To this end. first, the influence of parameters were examined with twenty eight test results obtained from references. Then, an experimental study was carried out with nine specimens. Test variables were the reinforcing ratio and the prestressing ratio. Specimens were divided equally into three groups and each group had a different level of the reinforcing ratio. Each specimen within a group has a different level of the prestressing ratio. The investigation with previous and current tests revealed the followings; (1) the length of crack distribution zone does not have a close relation with the length of plastic hinge. (2) the prestressing ratio does not affect both the length of crack distribution and the length of plastic hinge, (3) the tendon stress variation is in reverse relation with the ratios of mild steels and tendons, (4) the loading type nay not affect significantly the length of crack distribution zone, (5) AASHTO LRFD Code equation and Moon/Lim's design equation predicted the test results well with some safety margins.

  • PDF

외부긴장재를 이용한 프리스트레스트 콘크리트 거더교의 성능평가 (Performance Evaluation of Prestressed Concrete Girder Bridges by External Tendon)

  • 박승범;방명석;홍석주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.685-688
    • /
    • 1999
  • The analysis and design of composite girders prestressed by external tendons involve difficulties related to the position of anchorages and the construction sequences. In this paper, the efficiency of the external tendon profiles and the position of anchorages in examined for the internal and external prestressing of statically indeterminate structures. It is shown that strengthening of a prestressed girder can be accomplished using a variety of methods; bonded external prestressing, tendon replacement and unbonded external prestressing.

  • PDF

외부긴장재와 연속화에 의한 프리스트레스트 콘크리트 거더교의 성능평가 (Performance Evaluation of Prestressed Concrete Girder Bridges by External Tendon and Continuous Beams)

  • 박승범;방명석;홍석주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.681-684
    • /
    • 1999
  • The development of external prestressing methods has been one of the major trends in the concrete bridge constructions over the past decades. One of the promising methods to enhance the flexural strength of a externally prestressed girder is to place the tendons with large eccentricities. The test results in this study showed that the external prestressing of a composite girder increased the range of the elastic behavior, reduced deflections, increased ultimate strength, and added to the redundancy by providing the multiple stress paths. This study was conducted on the concrete bridges reinforced by the continuous girders and the external prestressing.

  • PDF

Evaluation of behavior and strength of prestressed concrete deep beams using nonlinear analysis

  • Kim, T.H.;Cheon, J.H.;Shin, H.M.
    • Computers and Concrete
    • /
    • 제9권1호
    • /
    • pp.63-79
    • /
    • 2012
  • The purpose of this study is to evaluate the behavior and strength of prestressed concrete deep beams using nonlinear analysis. By using a sophisticated nonlinear finite element analysis program, the accuracy and objectivity of the assessment process can be enhanced. A computer program, the RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology), was used for the analysis of reinforced concrete structures. Tensile, compressive and shear models of cracked concrete and models of reinforcing and prestressing steel were used to account for the material nonlinearity of prestressed concrete. The smeared crack approach was incorporated. A bonded or unbonded prestressing bar element is used based on the finite element method, which can represent the interaction between the prestressing bars and concrete of a prestressed concrete member. The proposed numerical method for the evaluation of behavior and strength of prestressed concrete deep beams is verified by comparing its results with reliable experimental results.

Cracked Section Analysis for Partial Prestressing Design

  • Song Jong Young;Jang Seok Hun;Kang Dong Ok;Cho Ik Sun
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.225-228
    • /
    • 2005
  • In this paper, an example of nonlinear analysis for partial prestressing design is presented. For partial prestressing design, the stress redistribution, after concrete cracking has occurred, should be accurately investigated by nonlinear analysis tools. Direct and iterative methods of nonlinear analyses were adopted for the tender design of the Incheon Bridge viaducts. Stress variations in the prestressing tendons and reinforcing bars were investigated and presented in this paper for both the in-service condition and during construction.

  • PDF

비부착 탄소섬유판 긴장재를 갖는 철근 콘크리트 보의 휨거동 (Flexural behavior of RC beams with unbonded prestressing CFRP laminates)

  • 박종섭;박영환;정우태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.258-261
    • /
    • 2006
  • This study investigates the flexural behavior and strengthening performance of RC beams with unbonded prestressing CFRP laminates through static bending tests. The aluminum anchorage system has been developed in tins study and successfully applied to the test specimens. The prestressing level of CFRP laminatehas was 0 %, 20 %, 30% and 50 % of its tensile strength. Experimental results revealed that RC beams with unbonded prestressing CFRP laminates showed increased crack load and yield load according to the level of prestress. It has also been observed that the length of the CFRP laminates does not have significant effect on the maximum load.

  • PDF

Time dependent service load behaviour of prestressed composite tee beams

  • Uy, Brian
    • Structural Engineering and Mechanics
    • /
    • 제5권3호
    • /
    • pp.307-327
    • /
    • 1997
  • This paper is concerned with the time dependent service load behaviour of prestressed composite tee beams. The effects of creep and shrinkage of the concrete slab are modelled using the age adjusted effective modulus method and a relaxation approach. The tendon strain is determined considering compatibility of deformations and equilibrium of forces between the tendon and the composite tee beam. A parametric study is undertaken to study the influence of various aspects on the stress, strain and deformations of the concrete slab, steel beam and prestressing tendon. The effect of loading type and tendon relaxation has also been considered for various types of prestressing tendon materials. Recommendations are then made in relation to adequate span to depth ratios for varying levels of prestressing force.

Numerical study of a new constructive sequence for movable scaffolding system (MSS) application

  • Teran, Jose Ramon Diaz de;Haach, Vladimir Guilherme;Turmo, Jose;Jorquera, Juan Jose
    • Advances in concrete construction
    • /
    • 제4권3호
    • /
    • pp.173-194
    • /
    • 2016
  • This paper consists in a study of a new contructive sequence of road viaducts with Movable Scaffolding System (MSS) using numerical tools based on finite element method (FEM). Traditional and new sequences are being used in Spain to build viaducts with MSS. The new sequence permits an easier construction of one span per week but implies some other issues related to the need of two prestressing stages per span. In order to improve the efficiency of the new sequence by reducing the number of prestressing stages per span, two solutions are suggested in this study. Results show that the best solution is to introduce the 100% of the prestressing force at the self-supporting core in order to improve the road viaduct construction with movable scaffolding system by reducing execution time without increasing economic costs.