• Title/Summary/Keyword: Pressurization of Pipe

Search Result 18, Processing Time 0.025 seconds

Effect of pressurization on dissolution of a supercooled aqueous solution with a stationary state (가압조건이 정지상태 과냉각 수용액의 해소에 미치는 영향)

  • Kim, Byung-Seon;Peck, Jong-Hyun;Hong, Hi-Ki;Kang, Chae-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.132-137
    • /
    • 2006
  • Supercooled type ice slurry system is hard to keep a proper supercooling degree when solution becomes supercooling state. This is the reason of the ice blockage in pipe or cooling part due to an unstable cooling state. In this study, a cooling experiment was performed to pressurized solution in a stationary state. The behaviors during the supercooled aqueous solution were investigated at fixed flow rate of brine and aqueous solution of ethylene glycol 7 mass%. Also the effect to the freezing point of supercooled aqueous solution was investigated to the different pressure 101, 202, 303, and 404 kPa. At results, the pressure of the aqueous solution in the cylinder increased the supercooling degree increased and dissolution of supercooled point decreased.

  • PDF

Absorption Properties of Coarse Aggregate according to Pressurization for Development of High Fluidity Concrete under High Pressure Pumping (고압송용 고유동콘크리트 개발을 위한 가압에 따른 굵은골재의 흡수 특성)

  • Choi, Yun-Wang;Choi, Byung-Keol;Oh, Sung-Rok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.122-129
    • /
    • 2016
  • In this study, we developed a pressing device which can reproduce the pressure of concrete inside the conveying pipe as a part of the basic study to development of high fluidity concrete under high pressure pumping. Using this pressing device, we evaluated a absorption properties of aggregate that are crushed coarse aggregate, river gravel and lightweight coarse aggregate according to pressure of coarse aggregate and aggregate inside a high fluidity concrete, focused on the reduction of unit water quantity by pressure. In addition, it was evaluated the compressive strength of high fluidity concrete about before and after of pressive. Test a result, case of condition under the high pressure of 250 bar, absorption ratio of crushed coarse aggregate and river gravel were not increased above the surface absorption, absorption ratio of lightweight coarse aggregate was increased than the surface absorption.

Investigation of Chill Down Characteristics of Liquid Oxygen Feeding System in 75 Tonf-class Liquid Rocket Engine Firing Test (75톤급 액체로켓엔진 연소시험에서의 액체산소 공급부 예냉특성 고찰)

  • Seo, Daeban;Cho, Namkyung;Han, Yeoungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.108-116
    • /
    • 2018
  • A firing test of the 75 tonf-class liquid rocket engine to be used as the first and second stage engines of the KSLV-II was carried out at the rocket engine test facility(RETF). Since this engine uses liquid oxygen as the oxidizer, which is a cryogenic fluid, it is essential that the chill down of the supply pipe line and engine proceed for the firing test; thus, the given inlet requirements must be met. Moreover, it is important to understand the chill down characteristics of the facility and the engine and the amount of liquid oxygen consumed in the chill down process for efficient test operation in the future. In this paper, chill down characteristics of the supply pipe and the engine were evaluated through the investigation of the chill down process of the 75 tonf-class liquid rocket engine at each stage before and after run tank pressurization. In addition, the amount of liquid oxygen consumed was also evaluated.

A Study on the Performance of COMS CPS during LEOP (천리안 위성의 LEOP기간 동안의 추진계 성능 연구)

  • Chae, Jong-Won;Han, Cho-Young;Yu, Myoung-Jong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.3
    • /
    • pp.258-263
    • /
    • 2012
  • In this paper the Chemical Propulsion Subsystem of COMS is briefly explained and some telemetries acquired by a series operations of CPS during the Launch and Early Operation Phase of COMS are presented. The pressure and temperature of pressurant tank telemetries are compared with the results of the developed computer program. The changes in pressure are due to the two major phases. The first one is the initialization phases of CPS composed of the venting phase to vent the helium gas in the pipe network from the downstream of the propellant tanks to the thrusters for safety, the priming phase to fill the vented pipe network with oxidizer and fuel respectively and then the pressurization phase to pressurize the ullage of propellant tank to regulated pressure. And the other is the apogee engine firings in which COMS CPS is in the orbit raising phase to use helium as a pressurant to keep the pressure of propellant tank as the liquid apogee engine get fired until COMS reached to the target orbit. This program can be applicable to prepare basis design data of the next Geostationary Satellite CPS.

산화제 공급배관의 분기 위치에 따른 추진기관 성능 비교

  • Kim, Ji-Hoon;Lee, Han-Ju;Jung, Dong-Ho;Oh, Seung-Hyub
    • Aerospace Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.179-185
    • /
    • 2005
  • It is an essential subject to decrease the mass of a launch vehicle for improving performance and efficiency of space launch system. Particularly, reducing the engine supporting area is necessary for high efficiency of propulsion system with clustered engine systems. The engine supporting area is related to the branch location of the oxidizer feeding line. This article deals the performance variation of the propulsion system such as the mass of the oxidizer feeding line, pressurization pressure of the oxidizer tank, and the onset of nucleation boiling in the oxidizer pipe with the branch location of the main feeding line.

  • PDF

Heat Exchanger Design Analysis for Propellant Pressurizing System of Satellite Launch Vehicles (소형위성 발사체용 추진제 가압 열교환기 설계 해석)

  • Lee H. J.;Han S. Y.;Chung Y. G.;Cho N. K.;Kil G. S.;Kim Y. K.
    • Journal of computational fluids engineering
    • /
    • v.9 no.3
    • /
    • pp.49-56
    • /
    • 2004
  • A heated and expanded helium is used to pressurize liquid propellants in propellant tanks of propulsion system of liquid propellant launch vehicles. To produce a heated and expanded helium, an hot-gas heat exchanger is used by utilizing heat source from an exhausted gas, which was generated in a gas generator to operate turbine of turbo-pump and dumped out through an exhaust duct of engine. Both experimental and numerical approaches of hot-gas heat exchanger design were conducted in the present study. Experimentally, siliconites - electrical resistance types - were used to simulate the full heat condition instead of an exhausted gas. Cryogenic heat exchangers, which were immersed in a liquid nitrogen pool, were used to feed cryogenic gaseous helium in a hot-gas heat exchanger. Numerical simulation was made using commercially utilized solver - Fluent V.6.0 - to validate experimental results. Helically coiled stainless steel pipe and stainless steel exhausted duct were consisted of tetrahedron unstructured mesh. Helium was a working fluid Inside helical heat coil and regarded as an ideal gas. Realizable k-』 turbulent modeling was adopted to take turbulent mixing effects in consideration. Comparisons between experimental results and numerical solutions are Presented. It is observed that a resulted hot-gas heat exchanger design is reliable based on the comparison of both results.

Thermal-hydraulic behaviors of a wet scrubber filtered containment venting system in 1000 MWe PWR with two venting strategies for long-term operation

  • Dong, Shichang;Zhou, Xiafeng;Yang, Jun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1396-1408
    • /
    • 2020
  • Filtered containment venting system (FCVS) is one of the severe accident mitigation systems designed to release containment pressurization to maintain its integrity. The thermal-hydraulic behaviors in FCVSs are important since they affect the operation characteristics of the FCVS. In this study, a representative FCVS was modeled by RELAP5/Mod3.3 code, and the Station BlackOut (SBO) was chosen as an accident scenario. The thermal-hydraulic behaviors of an FCVS during long-term operation with two venting strategies (open-and-close strategy, open-and-non-close strategy) and the sensitivity analysis of important parameters were investigated. The results show that the FCVS can operate up to 250 h with a periodic open-and-close strategy during an SBO. Under the combined effects of steam condensation and water evaporation, the solution inventory in the FCVS increases during the venting phase and decreases during the intermission phase, showing a periodic pattern. Under this condition, the appropriate initial water level is 3-4 m; however, it should be adjusted according to the environment temperature. The FCVS can accommodate a decay heat power of 150-260 kW and may need to feed water for a higher decay heat power or drain water for a lower decay heat power during the late phase. The FCVS can function within an opening pressure range from 450 kPa to 500 kPa and a closing pressure range between 250 kPa and 350 kPa. When the open-and-non-close strategy is adopted, the solution inventory increases quickly in the early venting phase due to steam condensation and then decreases gradually due to the evaporation of water; drying-up may occur in the late venting phase. Decreasing the venting pipe diameter and increasing the initial water level can mitigate the evaporation of the scrubbing solution. These results are expected to provide useful references for the design and engineering application of FCVSs.

Modelling of Fault Deformation Induced by Fluid Injection using Hydro-Mechanical Coupled 3D Particle Flow Code: DECOVALEX-2019 Task B (수리역학적연계 3차원 입자유동코드를 사용한 유체주입에 의한 단층변형 모델링: DECOVALEX-2019 Task B)

  • Yoon, Jeoung Seok;Zhou, Jian
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.320-334
    • /
    • 2020
  • This study presents an application of hydro-mechanical coupled Particle Flow Code 3D (PFC3D) to simulation of fluid injection induced fault slip experiment conducted in Mont Terri Switzerland as a part of a task in an international research project DECOVALEX-2019. We also aimed as identifying the current limitations of the modelling method and issues for further development. A fluid flow algorithm was developed and implemented in a 3D pore-pipe network model in a 3D bonded particle assembly using PFC3D v5, and was applied to Mont Terri Step 2 minor fault activation experiment. The simulated results showed that the injected fluid migrates through the permeable fault zone and induces fault deformation, demonstrating a full hydro-mechanical coupled behavior. The simulated results were, however, partially matching with the field measurement. The simulated pressure build-up at the monitoring location showed linear and progressive increase, whereas the field measurement showed an abrupt increase associated with the fault slip We conclude that such difference between the modelling and the field test is due to the structure of the fault in the model which was represented as a combination of damage zone and core fractures. The modelled fault is likely larger in size than the real fault in Mont Terri site. Therefore, the modelled fault allows several path ways of fluid flow from the injection location to the pressure monitoring location, leading to smooth pressure build-up at the monitoring location while the injection pressure increases, and an early start of pressure decay even before the injection pressure reaches the maximum. We also conclude that the clay filling in the real fault could have acted as a fluid barrier which may have resulted in formation of fluid over-pressurization locally in the fault. Unlike the pressure result, the simulated fault deformations were matching with the field measurements. A better way of modelling a heterogeneous clay-filled fault structure with a narrow zone should be studied further to improve the applicability of the modelling method to fluid injection induced fault activation.