• Title/Summary/Keyword: Pressure-drop Coefficient

검색결과 383건 처리시간 0.022초

냉각유동이 자동차항력에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Aerodynamic Drag of Model Cars with Cooling Air Passage)

  • 안이기;정형호;김광호
    • 대한기계학회논문집
    • /
    • 제18권2호
    • /
    • pp.405-413
    • /
    • 1994
  • This paper presents the experimental results of aerodynamic drags of model cars. The effects of cooling air on total drag were introduced by using momentum theorem. Vehicle-liked Ahmed body and 1/5 model car were used to evaluate the increments of drags due to the internal flow. The results were compared with momentum theorem and other's experiments and showed good agreements. In the case of Ahmed body, drags were increased by 22% due to the internal flow and decreased linealy by reducing internal air flow rates and inlet areas. The experiments on 1/5 model car with ill-defined air flow passage showed 10% increment of drag. The results of present study showed that cooling drag could be predicted by momentum theorem within small errors.

Measurement of the Thermal Characteristics of Finned-tube Heat Exchanger Fin by Using the Liquid Crystal Technique

  • Kang, Hie-Chan;Kim, Moo-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권2호
    • /
    • pp.28-35
    • /
    • 2001
  • This study deals with the thermal characteristics of finned-tube heat exchanger having two rows used in the air-conditioning application. Pressure drop and heat transfer coefficient were measured by using the three times models of plain fin and compared with the theory. Also the temperature distribution and heat conduction in the fin was measured by using the liquid crystal method. The surface temperature of rear row was nearly constant, and heat conduction in the fin was stronger near the front row than the rear row.

  • PDF

RIPPLE TUBE의 열전달(熱傳達) 특성(特性)에 관(關)한 실험적(實驗的) 연구(硏究) (An Experimental Study on Heat Transfer Characteristics of a Ripple Tube)

  • 최승성
    • 설비공학논문집
    • /
    • 제2권4호
    • /
    • pp.316-326
    • /
    • 1990
  • The measurements of heat transfer and pressure drop were performed on ripple tube with air flow. The results with the tube were compared with the performance of smooth tube. The enhancements in heat transfer coefficient for ripple tube, being compared with smooth tube, was ranged from 7.4 to 39 percent. The local Nusselt number for the inner fin tube, being compared with that for smooth tube, varied from 7.4% to 39%, while the corresponding increase in friction factors were 4.1 to 8.1%. One of the most direct indications of Nusselt number of ripple tube is given as following equation: $$Nu=0.061Re^{0.75}Pr^{0.4}(Tb/Tw)^{0.5}$$ We can see that Nusselt number for ripple tube in this experiment is consistent with the theoretical one taken from Walkinson's equation at Reynolds number range from 8,000 to 20,000.

  • PDF

핀 간격(間隔)이 루우버핀 열교환기(熱交換器)의 공기측(空氣側) 열전달(熱傳達)에 미치는 영향(影響) (Effect of Fin Spacings on Air-side Heat Transfer in Louvered Fin Heat Exchangers)

  • 김선정;정태현;권순석
    • 설비공학논문집
    • /
    • 제2권4호
    • /
    • pp.288-294
    • /
    • 1990
  • A study has been conducted experimentally on heat transfer characteristics of louvered fin heat exchangers with various fin spacings in air. The experimental results are as follows; 1. Mean heat transfer coefficient is increased with increasing air velocity and the optimum fin spacing shows at S=5mm. 2. Pressure drop is increased with increasing air velocity and its maximum value shows at S=3.5mm and its minimum value shows at S=6mm. 3. $\bar{h}/{\Delta}P$ is decreased with increasing air velocity and its maximum value shows at S=5mm and its minimum value shows at S=3.5mm.

  • PDF

빙축열 시스템의 제빙용 열교환기내에서 유동 및 열전달 특성 (Flow and Heat Transfer Characteristics in Ice Making Heat Exchanger Applied to Ice-Storage System)

  • 백영렬;이재헌
    • 설비공학논문집
    • /
    • 제6권2호
    • /
    • pp.110-119
    • /
    • 1994
  • Three dimensional characteristics of fluid flow and heat transfer have been studied numerically around the latent heat storage vessel which was applied to the practical ice-storage system. The result obtained indicates that the value of frictional coefficient decreases with decrease of baffle width. For the baffle spacing. $S/H_D=9.375$, baffle height. $H/H_D=0.5$ and various pressure drop, average Nusselt numbers in heat transfer surface are much dependent on the width of side baffle and middle baffle. that is. Nu_m decreases with decrease of the width of middle baffle when the width of side baffle is 4.375, where as the optimum condition of side baffle for $Nu_m$ exists in the range of 3.5< $B_1/H_D$ <4.375 at the width of middle baffle, $B_2/H_D=6.875$.

  • PDF

초전도케이블 냉각시스템의 냉각특성 시험 (Test of The HTS Power Cable Cooling System)

  • 염한길;고득용;김익생;김춘동;김도형
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.281-283
    • /
    • 2003
  • High temperature superconducting power cable requires forced flow cooling. Liquid nitrogen is circulated by a pump and cooled back by cooling system. Typical operating temperature range is expected to be between 65K and 80K. Subcooler heat exchanger uses saturated liquid nitrogen boiling on the shell side to subcool the circulating liquid nitrogen stream that cools the HTS cable. The paper describes performance tests of the cooling system. The test items are heat exchanging performance of subcooler. pressure drop between supply and return lines, heat transfer coefficient inside former, cable cryostat heat leak and simulation of electrical load of HTS cable.

  • PDF

컴퓨터 CPU 냉각용 라디에이터의 열성능에 관한 연구 (A Study on the Thermal Performance of Radiator for Computer CPU Cooling)

  • 차동안;권오경;최미진;윤재호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.258-263
    • /
    • 2007
  • The performance of louver-finned flat-tube radiators for computer CPU liquid cooling were experimentally investigated. In this study, 5 samples of louver-finned flat-tube radiators with different width size (19mm, 24mm), tube hole (1, 9) and pass number (1, 2, 5) were tested in a wind tunnel. The experiments were conducted under the different air velocity ranging from 1 to 5 m/s. The water flow rate through a pass was 1.7 LPM. Inlet temperatures of air and water were $20^{\circ}C$ and $30^{\circ}C$ respectively. The results showed that the best performance in the 24mm sample considering pressure drop and heat transfer coefficient.

  • PDF

파형관을 가진 이중 환형관의 열전달에 관한 실험적 연구 (Experimental Studies on Heat Transfer in the Annuli with Corrugated Tubes)

  • 안수환;손강필
    • 설비공학논문집
    • /
    • 제14권8호
    • /
    • pp.683-689
    • /
    • 2002
  • This paper is to present the results of a comprehensive study on heat transfer in annuli with spirally corrugated inner tubes in the turbulent regime. Tube surface-temperature measurements were used to explain the enhancement phenomena in the annuli with several different corrugated tubes. Nusselt numbers were between 1.1 and 2 times the smooth annulus values. These enhancement values can be used to determine the appropriate range of applicability for spirally corrugated annuli.

연도가스 열회수용 다관형 순환유동층 열교환기 성능실험 (Performance Test of a Multi-riser Fluidized Bed Heat Exchanger for Flue Gas Heat Recovery)

  • 전용두;이금배
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.273-279
    • /
    • 2004
  • A lab-scale fluidized bed heat exchanger for waste gas heat recovery is devised and tested. Compared to our previous works on fluidized bed type system with a single riser, the present heat exchanger system is featured by its multiple (four) risers to handle increased amount of exhaust gas. Particles are introduced to the main hot gas stream alongside the pipe circumference near riser inlets. The heat exchanger performance and pressure drop are evaluated through experiments for the present gas-to-water heat exchanger system.

베어링 강(STB2)의 마멸에 미치는 알루미나 세라믹스의 마멸기구 (A Study on the Wear Mechanism of the Alumina Ceramics for the Wear of STB2)

  • 남준우;전태옥;진동규
    • 한국정밀공학회지
    • /
    • 제12권3호
    • /
    • pp.62-72
    • /
    • 1995
  • The present study was undertaken to investigate the dry wear mechanism of the alumina ceramics in the purity variation for the wear of STB2. The wear test was carried out under different experimental condition various sliding speed, contact pressure and sliding distance. According as the alumina purity increased, wear volume of the STB2 decreased and minimum value of wear volume was over to high speed side. According as the sliding speed and sliding distance increased, friction coefficient decreased owing to drop of the shear strength, it decresed largely owing to decreased of elastic modulus and thermal conductivity with decrease in alumina purity. Indicative of minimum, value of wear volume, low speed side was abrasive wear, high speed side was wear of heat softening. The friction surface of ceramics protacted by oxide was transfer from STB2.

  • PDF