• Title/Summary/Keyword: Pressure-based Algorithm

Search Result 410, Processing Time 0.033 seconds

Development of a Low-noise Regenerative Blower for Fuel Cell Application (연료전지용 저소음 재생형 송풍기의 개발)

  • Kim, Jun Kon;Lee, Kwang Yeong;Lee, Chan;Kil, Hyun Gwon;Chung, Kyung Ho;Hwang, Sang Moon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.2
    • /
    • pp.48-53
    • /
    • 2014
  • A low-noise regenerative blower is developed for fuel cell application by combining the FANDAS-Regen code and design optimization algorithm under several performance constraints for flow capacity, static pressure, efficiency and power consumption. The optimized blower design model is manufactured with some impeller modification based on low noise design concept and tested by using aerodynamic performance chamber facility and narrow-band noise measurement apparatus. The measured results of the optimized blower satisfy the performance requirements and are also compared favorably with the FANDAS-Regen prediction results within a few percent relative error. Furthermore, the present study shows the remarkable noise reduction by 26 dBA can be achieved through design optimization and low noise design concept.

Flow-induced Vibration Time Response Analysis of Loosely Supported Multi-Span Tube using Commercial FEA Code (지지점 간극을 갖는 다점지지 유연관의 유동하중에 의한 시간응답 이력해석과 상용유한요소 해석코드의 적용)

  • Lee, Kang Hee;Kang, Heung Seok;Shin, Chang Hwan
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.2
    • /
    • pp.68-74
    • /
    • 2015
  • Time domain response analysis for vibro-impact nonlinear behavior of multi-span tube with loose supports was performed using commercial FEA code and user subroutine. Support geometry of multi-span tube with a finite gap is realistically modeled by analytical rigid surface. Model of hydrodynamic force is based on the Qusai-steady model which accounts for the inclined angle of relative flow velocity and time delay between flow force and resulting tube motion. During tube vibration from flow loading, impact and friction at the support location is simulated using commercial FEA code with master slave contact algorithm. Analysis results has reasonable agreement with those of references and test experience. Plan of further refinement of analysis model and future test verification is briefly introduced.

Counter-Rotating Streamwise Vortex Formation in the Turbine Cascade with Endwall Fence

  • Koh Seong Ryong;Moon Young J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1999.05a
    • /
    • pp.155-161
    • /
    • 1999
  • The three-dimensional turbulent cascade flows with and without endwall fences are numerically investigated by solving the incompressible Navier-Stokes equations with a high-Reynolds number $k-{\varepsilon}$ turbulence closure model. A projection method based algorithm is used in the finite-volume formulation, with the second order upwind-differencing scheme for the convective terms. First, assessments on accuracy of the present method are made by comparing the static pressure distributions at the mid-span of the cascade with measured data, and also by confirming the experimental observations on the choice of an optimal fence height for the secondary flow control. In understanding the three-dimensional nature of the secondary flow in turbine cascade, the limiting streamline patterns and the static pressure contours at the suction surface of the blade as well as on the cascade endwall are employed to visualize the effectiveness of the endwall fence for the secondary flow control. Analysis on the streamwise vorticity contour maps along the cascade with the three-dimensional representation of their iso-surfaces reveals the strucuture of the complicated vortical flow in the turbine cascade with endwall fence, and also leads to an understanding on formation of the counter-rotating streamwise vortex over the endwall fence, in explaining the mechanisms of controlling the secondary flow and also for the proper selection of an optimal fence height.

  • PDF

Development of Hardware and Monitoring Software for Stable Operation of Fire Pumps (소방펌프의 안정적 운영을 위한 하드웨어 및 모니터링 소프트웨어 개발)

  • Ku, Bonhyu;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.28-35
    • /
    • 2022
  • This study is aimed to develop a safety diagnosis system for fire pumps that detects normal and abnormal signals for the stable operation of the system. Hence, the following activities were carried out: first, a threshold value was identified for the normal operation and six abnormal operations (adherence of impeller, absence of water source, separation of pump and motor, run-stop operation, air inflow into the casing, and reverse-phase loss of the power line) reflecting changes in the current, flow and pressure of fire pumps; secondly, based on the identified signals, an algorithm capable of detecting three abnormal signals was developed and in terms of hardware, a current, pressure and flow sensor suitable for the analogue input values of NI-6009 was designed and installed. This combination of the hardware and software is applicable as a diagnosis system to ensure the stable operation of fire pumps.

Automatic Control System on Cardiac Output Regulation for the Moving Actuator Type Total Artificial Heart (MOVING-ACTUATOR TYPE 인공심장의 심박출 조절에 대한 자동 제어방법)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • v.28 no.6
    • /
    • pp.542-548
    • /
    • 1995
  • The goal of this study is to develop an effective control system for cardiac output regulation based upon the preload and afterload conditions without any transducers and compliance chambers in the moving actuator type total artificial heart. Motor current waveforms during the actuator movement are used as an input to the automatic control algorithm. While the current waveform analysis is performed, the stroke length and velocity of the actuator are gradually increased up to the maximum pump output level. If the diastolic filling rate of either right or left pump begins to exceed the venous return, atrial collapse will occur. Since the diastolic suction acts as a load to the motor, this critical condition can be detected by analyzing the motor current waveforms. Every time this detection criterion is met, the control algorithm decreases the stroke velocity and length of the actuator step by step just below the critical detection level. Then, they start to increase. In this way the maximum pump output under given venous return can be achieved. Additionally the control algorithm provides some degree of afterload sensitivity. If the aortic pressure is detected to exceed 120 mmHg, the stroke length and velocity decrease in the same way as the response to the preload. Left-right pump output balance is maintained by proper adjustment of the asymmetry of the stroke angle. In the mock circulatory test, this control system worked well and there was a considerable range of stroke volume difference with adjustment of the asymmetry value. Two ovine experiments were performed. It was confirmed that the required cardiac output regulation according to the venous return could be achieved with adequate detection of diastolic function, at least in the in vivo short-term survival cases[2-3 days . We conclude that this control algorithm is a promising method to regulate cardiac output in the moving actuator type total artificial heart.

  • PDF

Adaptive Blowing Control Algorithm for Autonomous Control of Underwater Flight Vehicle (수중 비행체의 자율제어를 위한 적응 부상 제어 알고리즘)

  • Kim, Hyun-Sik
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.18 no.4
    • /
    • pp.482-487
    • /
    • 2008
  • In case of flooding, the underwater flight vehicle (UFV) executes the blowing by blowing ballast tanks off using high pressure air (HPA), while it also uses control planes and a propulsion unit to reduce the overshoot depth caused by a flooding and blowing sequence. However, the conventional whole HPA blow-off method lets the body on the surface after blowing despite slight flooding. This results in the unnecessary mission failure or body exposure. Therefore, it is necessary to keep the body at the near surface by the blowing control while reducing the overshoot depth. To solve this problem, an adaptive blowing control algorithm, which is based on the decomposition method expanding the expert knowledge in depth control and the adaptive method using fuzzy basis function expansion (FBFE), is proposed. To verify the performance of the proposed algorithm, the blowing control of UFV is performed. Simulation results show that the proposed algorithm effectively solves the problems in the UFV blowing control system online.

Couette-Poiseuille flow based non-linear flow over a square cylinder near plane wall

  • Bhatt, Rajesh;Maiti, Dilip K.;Alam, Md. Mahbub;Rehman, S.
    • Wind and Structures
    • /
    • v.26 no.5
    • /
    • pp.331-341
    • /
    • 2018
  • A numerical study on the flow over a square cylinder in the vicinity of a wall is conducted for different Couette-Poiseuille-based non-uniform flow with the non-dimensional pressure gradient P varying from 0 to 5. The non-dimensional gap ratio L (=$H^{\ast}/a^{\ast}$) is changed from 0.1 to 2, where $H^{\ast}$ is gap height between the cylinder and wall, and $a^{\ast}$ is the cylinder width. The governing equations are solved numerically through finite volume method based on SIMPLE algorithm on a staggered grid system. Both P and L have a substantial influence on the flow structure, time-mean drag coefficient ${\bar{C}}_D$, fluctuating (rms) lift coefficient ($C_L{^{\prime}}$), and Strouhal number St. The changes in P and L leads to four distinct flow regimes (I, II, III and IV). Following the flow structure change, the ${\bar{C}}_D$, $C_L{^{\prime}}$, and St all vary greatly with the change in L and/or P. The ${\bar{C}}_D$ and $C_L{^{\prime}}$ both grow with increasing P and/or L. The St increases with P for a given L, being less sensitive to L for a smaller P (< 2) and more sensitive to L for a larger P (> 2). A strong relationship is observed between the flow regimes and the values of ${\bar{C}}_D$, $C_L{^{\prime}}$ and St. An increase in P affects the pressure distribution more on the top surface than on bottom surface while an increase in L does the opposite.

Diffusion-hydraulic properties of grouting geological rough fractures with power-law slurry

  • Mu, Wenqiang;Li, Lianchong;Liu, Xige;Zhang, Liaoyuan;Zhang, Zilin;Huang, Bo;Chen, Yong
    • Geomechanics and Engineering
    • /
    • v.21 no.4
    • /
    • pp.357-369
    • /
    • 2020
  • Different from the conventional planar fracture and simplified Newton model, for power-law slurries with a lower water-cement ratio commonly used in grouting engineering, flow model in geological rough fractures is built based on ten standard profiles from Barton (1977) in this study. The numerical algorithm is validated by experimental results. The flow mechanism, grout superiority, and water plugging of pseudo plastic slurry are revealed. The representations of hydraulic grouting properties for JRCs are obtained. The results show that effective plugging is based on the mechanical mechanisms of the fluctuant structural surface and higher viscosity at the middle of the fissure. The formulas of grouting parameters are always variable with the roughness and shear movement, which play a key role in grouting. The roughness can only be neglected after reaching a threshold. Grouting pressure increases with increasing roughness and has variable responses for different apertures within standard profiles. The whole process can be divided into three stationary zones and three transition zones, and there is a mutation region (10 < JRCs < 14) in smaller geological fractures. The fitting equations of different JRCs are obtained of power-law models satisfying the condition of -2 < coefficient < 0. The effects of small apertures and moderate to larger roughness (JRCs > 10.8) on the permeability of surfaces cannot be underestimated. The determination of grouting parameters depends on the slurry groutability in terms of its weakest link with discontinuous streamlines. For grouting water plugging, the water-cement ratio, grouting pressure and grouting additives should be determined by combining the flow conditions and the apparent widths of the main fracture and rough surface. This study provides a calculation method of grouting parameters for variable cement-based slurries. And the findings can help for better understanding of fluid flow and diffusion in geological fractures.

Stress based Fatigue Life Prediction for Ball Bearing (응력 기반 볼 베어링의 접촉피로수명 예측)

  • Kim Tae-Wan;Lee Sang-Don;Cho Yong-Joo
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.339-349
    • /
    • 2004
  • The method for fatigue life prediction of ball bearing is proposed applying the algorithm of contact fatigue prediction based on stress analysis. In order to do this, a series of simulation such as initial surface stress analysis, EHL analysis, subsurface stress analysis and fatigue analysis are conducted from the loading at each ball location calculated for a bearing subjected to external bearing load and contact shape function. And uniaxial fatigue tests are performed to obtain fatigue parameter of AISI 52100 steel. It was found that since stress is usually higher at the inner raceway contact than at the outer raceway contact, fatigue failure occurs on the inner raceway first. When the fatigue life calculated in the stress-based method are compared with $L_{50}$ life of L-P model, Crossland criterion for the radial load increment is similar to $L_{50}$ life and Dang Van criterion for the axial load increment is similar. In the case of EHL contact. there is no difference of fatigue life between dry contact and EHL contact, when maximum Hertz pressure exceeds 2.5GPa.

  • PDF

Stress based Fatigue Life Prediction for Ball Bearing (볼 베어링의 응력 기반 접촉피로수명 예측)

  • Kim, Tae-Wan;Cho, Yong-Joo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.5
    • /
    • pp.44-55
    • /
    • 2007
  • The method for fatigue life prediction of ball bearing is proposed applying the algorithm of contact fatigue prediction based on stress analysis. In order to do this, a series of simulation such as initial surface stress analysis, EHL analysis, subsurface stress analysis and fatigue analysis are conducted from the loading at each ball location calculated for a bearing subjected to external bearing load and contact shape function. And uniaxial fatigue tests are performed to obtain fatigue parameter of AISI 52100 steel. It was found that since stress is usually higher at the inner raceway contact than at the outer raceway contact, fatigue failure occurs on the inner raceway first. When the fatigue life calculated in the stress-based method are compared with L50 life of L-P model, Crossland criterion for the radial load increment is similar to L50 life and Dang Van criterion for the axial load increment is similar. In the case of EHL contact, there is no difference of fatigue life between dry contact and EHL contact, when maximum Hertz pressure exceeds 2.5GPa.