• Title/Summary/Keyword: Pressure test rig

Search Result 99, Processing Time 0.022 seconds

Pressure Drop and Flow-Induced Vibration Test for the HANARO Non-instrumented Irradiation Test Rig of Annular Fuel Pellet (환형소결체 하나로 조사시험용 무계장 리그의 차압 및 유동유발 진동시험)

  • Lee, Kang-Hee;Kim, Dae-Ho;Bang, Jae-Gun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.281-286
    • /
    • 2007
  • Needs of fuel's performance evaluation for the dual-cooled fuel pellet (annular shape) necessitate the irradiation test in the test reactor. Irradiation test rig for the HARARO reactor, which is a special-purposed equipment used for material, irradiation and creep test, must satisfy the operational requirement on the hydraulic characteristics and structural integrity. In this paper, pressure drop and flow-induced vibration test for the newly developed non-instrumented test rig were carried out using FIVPET as a out-pile evaluation test. The test results show that the new test rig satisfy the HANARO operational requirement with sufficient margin. The spectral response characteristics of the flow-induced vibration of the test rid were also discussed.

  • PDF

A study on design and control of hydraulic test rig for performance evaluation of active suspension system (능동 현가시스템의 성능평가를 위한 유압식 시험기의 설계 및 제어에 관한 연구)

  • 손영준;이광희;이진걸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1445-1449
    • /
    • 1996
  • To evaluate of active suspension, it is necessary for special equipment - so called Test Rig which can perfectly realize the road condition and the impact from the road. And most of the test rig systems controlling force accurately and rapidly consist of electro-hydraulic servo mechanism, and they need robust controller which can endure outer road change. But in the case of PID controller, we should choose its best gains by trial and error method, and once its gains are fixed, they cannot get changed, so we should reset PID controller gains respectively when the road is changed. Therefore based on the load pressure feedback compensation method, our aim at constructing electro-hydraulic test rig is not affected by various road disturbance.

  • PDF

Development of 1/60th Scale Moving Model Rig Using the Compressed Air Launcher and One-Wire Guidance System of Train Model (압축공기 발사기에 단선 와이어 유도방식을 적용한 1/60축척 터널주행 열차모형 시험기 개발에 대한 연구)

  • Kim, Dong-Hyeon;O, Il-Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.634-644
    • /
    • 2001
  • The test facility of a 1/60-scale model for train-tunnel systems has been recently developed to investigate the effects of tunnel portal shapes, hood shapes and air-shafts for reducing the micro-pressure waves radiating towards the surroundings from the tunnel exit. The present test rig has been advanced from a 1/70-scale facility at NLR in Netherlands. The NLR test rig has the two-wise guidance system that needs two ears attached on the external surface of a model train nose. Therefore, their train models have irregular nose shapes. The main characteristics of the present facility are that the train model is guided by only one wire from the compressed air launcher to the absorber parts of test facility and the wire guidance hole is located at the axial center of a train model. In the present test rig, after a train model is launched, the air jet from the launcher does not enter the tunnel model. Experimental results were compared with numerical predictions to prove the performance of the test facility.

Development of Low Pressure Axial Compressor Performance Test Rig (1단 저압 축류압축기 성능시험리그 개발)

  • Yang, Jae-Jun;Bang, Jeong-Suk;Rhee, Byung-Ho;Park, Tae-Choon;Kang, Young-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.977-980
    • /
    • 2011
  • In this paper, explain to development of low pressure axial compressor performance test rig in KARI. Performance test rig consist of a entrance section, rotor, stator, shaft, rig housing, bearing housing and exit section. Test rig design structural optimization to rotor dynamics analysis of the simplified rotor-shaft assembly and flow analysis of entrance/exit section.

  • PDF

Pressure Characteristics on Korean High-Speed Railway Acoustic Screen Using 1/61 Scaled-Down Moving Model Rig

  • Jang, Yong-Jun;Kim, Hag-Beom;Jung, Woo-Sung;Kim, Dong-Hyeon
    • International Journal of Railway
    • /
    • v.2 no.2
    • /
    • pp.93-97
    • /
    • 2009
  • The experiments for aerodynamic characteristics of railway acoustic screen are performed using 1/61 scaled-down moving model rig facility which employs an axis symmetry and one wire guidance method. The launching mechanism is an air-gun type. The train model for the experiment is the high speed train (Korea Train Express: KTX) and the tested speed is about 300 km/h. The tested train length is 61 em which is corresponding to two units of KTX train. The cross sectional area and weight of train model are 0.00264 $m^2$ and 287 g, respectively. The Reynolds number based on the model train length is $1.2{\times}10^7$. The strength of pressure wave is measured using piezo typed pressure sensor. The measured pick value of pressure was as high as 365 Pa in the shortest gap between the acoustic screen and model train. The measured pressure is well compared with the field test data of mc 779-1 [2] values. However, the experimental data were slightly lower than the mc 779-1 values. The results show the model test can be used as a substitute for the field test.

  • PDF

Development of a new test facility for the study of pressure transients in tunnel and micro-pressure waves radiated from the tunnel exit on the railroad (철도터널내 압력변동 및 터널 미기압파 저감 시험장치개발에 관한 연구)

  • Kim, Dong-Hyeon;Oh, Il-Geun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.611-618
    • /
    • 2000
  • The test facility of the 1/60-scale models for the train-tunnel interactions was recently developed to investigate the effects of entry portal shapes, hood shapes and air-shafts for reducing the micro-pressure waves radiating to the surroundings of the tunnel exits by KRRI in Korea. The launching system of train model was chosen as air-gun type. In present test rig, after train model is launched, the blast wave by the driver did not enter to inside of the tunnel model. The train model is guided on the one-wire system from air-gun driver to the brake parts of test facility end. Some cases of the experiments were compared with numerical simulations to prove the test facility.

  • PDF

Aerodynamic Rig Test of Radial Turbine for APU (APU용 구심터빈의 공력리그시험)

  • Kang, Jeong-Seek;Lim, Byeung-Jun;Ahn, Iee-Ki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • An aerodynamic rig test of a radial turbine for an auxiliary power unit (APU) was performed at a high-temperature turbine test facility at the Korea Aerospace Research Institute. The pressure ratio, Mach number, and flow coefficient in the rig test are the same as those under normal engine operation conditions. The design pressure ratio is 3.096, design test speed is 34909 rpm, and turbine inlet temperature is $160^{\circ}C$. The turbine has airfoil-type nozzles, and the diameter of the turbine wheel is 175.74 mm. The turbine map is experimentally measured, and the detailed flow at the turbine inlet is measured. The pressure distribution in the nozzle at both the hub and the shroud sides and the pressure distribution along the shroud casing of the turbine wheel were measured, and this confirmed that the expansion process in the turbine wheel is acceptable.

Development and Test of Slinger Combustor for Micro Turbojet Engine (초소형 터보제트엔진 슬링거 연소기의 개발과 시험)

  • Lee, Dong-Hun;You, Gyung-Won;Choi, Seong-Man;Kim, Hyung-Mo;Park, Poo-Min;Choi, Young-Ho;Jeon, Byung-Ho;Park, Soo-Hyung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.149-152
    • /
    • 2008
  • A slinger combustor which can be applied to micro turbojet engine has been developed with the combustor rig test. A rotating fuel injector with high speed rpm was designed, manufactured and tested to apply into slinger combustor through spray test and adequate droplet size and spray distribution were achieved. The CFD was used to analyze internal flow of the combustor. We found out that the combustor shows 11.2% of pressure loss and 99.8% of combustion efficiency at full combustor rig test.

  • PDF

A Study on Performance Characteristics for a CNG Regulators of Automotive Vehicle (차량용 CNG 레귤레이터의 성능특성에 관한 연구)

  • Kim, Chang-Gi;Park, Cheol-Woong
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.12-16
    • /
    • 2007
  • The fuel pressure regulator mounted on CNG vehicles is used to maintain a constant pressure in the fuel injection system. It needs precise fuel pressure control to obtain benefits of high efficiency and low emissions in CNG vehicles. In this study, a high pressure test rig for the performance evaluation of CNG regulators was introduced. Two different CNG regulators were tested and compared each other at various test conditions. Results showed that dynamic response and creep characteristics are directly effected by the valve assembly design. Gas temperature was dramatically dropped at hish supply pressure conditions, so that effective design for coolant bowl is needed to prevent icing problem.

  • PDF

A Study of Simplified Test Rig for High Altitude Simulation (고고도 모사용 소형시험장치 연구)

  • Lee Ji-Hyung;Oh Jong-Yun;Park Ik-Soo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.4 s.19
    • /
    • pp.133-137
    • /
    • 2004
  • A simplified test rig to simulate high-altitude environments was designed by analyzing the AEDC (Arnolds Engineering Development Center) report regarding simulated altitude testing. The test rig consists of a vacuum chamber, a supersonic nozzle connected to a cold-gas supplier and a diffuser. The preliminary tests were conducted to validate the AEDC design concepts. The test results showed that sub-atmospheric pressure(1.0psia) environments were realized inside the vacuum chamber and the design concepts were confirmed.