• 제목/요약/키워드: Pressure signal

검색결과 913건 처리시간 0.023초

A Study on Water Level Control of PWR Steam Generator at Low Power Operation and Transient States (저출력 및 과도상태시 원전 증기발생기 수위제어에 관한 연구)

  • Na, Nan-Ju;Kwon, Kee-Choon;Bien, Zeungnam
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • 제3권2호
    • /
    • pp.18-35
    • /
    • 1993
  • The water level control system of the steam generator in a pressurized water reactor and its control problems are analysed. In this work the stable control strategy during the low power operation and transient states is studied. To solve the problem, a fuzzy logic control method is applied as a basic algorithm of the controller. The control algorithm is based on the operator's knowledges and the experiences of manual operation for water level control at the compact nuclear simulator set up in Korea Atomic Energy Research Institute. From a viewpoint of the system realization, the control variables and rules are established considering simpler tuning and the input-output relation. The control strategy includes the dynamic tuning method and employs a substitutional information using the bypass valve opening instead of incorrectly measured signal at the low flow rate as the fuzzy variable of the flow rate during the pressure control mode of the steam generator. It also involves the switching algorithm between the control valves to suppress the perturbation of water level. The simulation results show that both of the fine control action at the small level error and the quick response at the large level error can be obtained and that the performance of the controller is improved.

  • PDF

The Hearing Ability of Coralfish Chromis notatus to Low Frequency Sound 2. The Auditory Critical Ratio and Hearing Index (저주파음에 의한 자리돔의 청각 능력 2. 청각 임계비 및 청각능력지수)

  • 이창헌;서두옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • 제36권4호
    • /
    • pp.314-321
    • /
    • 2000
  • In order to obtain the fundamental data on the auditory thresholds of fishes for catching method using low frequency sound, the auditory thresholds of coralfish Chromis notatus were measured in the presence of masking noise in the spectrum level range of 73~83dB re l$\mu$Pa/√Hz by heartbeat conditioning technique using pure tones coupled with a delayed electric shock. Critical ratios were about 23~41dB at measurement frequency, The critical ratio increased almost linearly with increasing frequency from 500Hz. The noise spectrum level at the start of masking was about 60~65dB. This suggests that hearing of coralfish is masked in the natural environment with the noise spectrum level above 60dB. The sound pressure level of which the signal sound of 300Hz is recognized by coralfish under the ambient noise is above 88dB and the critical ratio of them is above 23dB. The hearing index of coralfish with ambient noise was 81.

  • PDF

The Effect of Psychological Factors of Speeding Behavior Using a Driving Simulator (Focused on Speeding Intention) (차량시뮬레이터를 이용한 과속운전의 심리적 요인 연구 (과속의도를 중심으로))

  • Ryu, Jun-Beom;Sin, Yong-Gyun;Park, Je-Jin
    • Journal of Korean Society of Transportation
    • /
    • 제29권1호
    • /
    • pp.39-46
    • /
    • 2011
  • Speeding is a major cause of traffic accidents that affects the safety of pedestrians and harms drivers and their families, property and mental health. However, most researches on speeding behavior have been conducted by survey method, so the relationship between cause and effect is not clear. The reliability of the research cannot be carefully examined because most researches involve retrospective methods. It is clear that conducting experimental research is important for overcoming these limitations, but it is impossible to perform tests with real cars in real traffic situations due to the inability to control situational factors (e.g., other vehicles, traffic signal) which affect participants' behavior. A car simulator experiment was designed and the theory of planned behavior was applied to the experiment. Each participant was grouped and assigned to either high speeding intention group or low speeding intention group according to their levels of speeding intention and analyzed the difference of driving behavior indexes between two groups. The results revealed statistically significant differences between two groups on driving speed, speeding frequency, and accelerator pressure deviation. Finally, the limitations and the implications of this study were discussed.

Proposition of a Vibration Based Acceleration Sensor for the Fully Implantable Hearing Aid (완전 이식형 보청기를 위한 진동 기반의 가속도 센서 제안)

  • Shin, Dong Ho;Mun, H.J.;Seong, Ki Woong;Cho, Jin-Ho
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • 제11권2호
    • /
    • pp.133-141
    • /
    • 2017
  • The hybrid acoustic sensor for implantable hearing aid has the structure in which a sound pressure based acoustic sensor (ECM) and a vibration based acceleration sensor are combined. This sensor combines the low frequency sensitivity of an acoustic sensor with the high frequency sensitivity of an acceleration sensor, allowing the acquisition of a wide range of sound from low to high frequency. In this paper, an acceleration sensor for use in a hybrid acoustic sensor has been proposed. The acceleration sensor captures the vibration of the tympanic membrane generated by the acoustic signal. The size of the proposed acceleration sensor was determined to diameter of 3.2 mm considering the anatomical structure of the tympanic membrane and the standard of ECM. In order to make the hybrid acoustic sensor have high sensitivity and wide bandwidth characteristics, the aim of the resonance frequency of the acceleration sensor is to be generated at about 3.5 kHz. The membrane of the acceleration sensor derives geometric structure through mathematical model and finite element analysis. Based on the analysis results, the membrane was implemented through a chemical etching process. In order to verify the frequency characteristics of the implemented membrane, vibration measurement experiment using external force was performed. The experiment results showed mechanical resonance of the membrane occurred at 3.4 kHz. Therefore, it is considered that the proposed acceleration sensor can be utilized for a hybrid acoustic sensor.

Effects of phenylephrine-induced PKC activation on Mg2+ release in guinea pig heart and isolated ventricular myocytes (기니픽 심장과 심근세포에서 Phenylephrine에 의한 PKC 활성화가 Mg2+ 유리에 미치는 영향)

  • Chang, Sung-eun;Kang, Hyung-sub;Kim, Jin-sang
    • Korean Journal of Veterinary Research
    • /
    • 제38권1호
    • /
    • pp.29-42
    • /
    • 1998
  • $Mg^{2+}$ is one of the most abundant divalent cations in mammalian body(0.2~1.0mM) and the important physiological roles are : first, the cofactor of many enzyme activities, second, the regulator of glycolysis and DNA synthesis, third, the important role of bioenergetics by regulating of phosphorylation, fourth, the influence of cardiac metabolism and function. In this work we have investigated the regulation of the $Mg^{2+}$ induced by ${\alpha}_1-adrenoceptor$ stimulation in perfused guinea pig hearts and isolated myocytes. The $Mg^{2+}$ content of the perfusate or the supernatant was measured by atomic absorbance spectrophotometry. The elimination of $Mg^{2+}$ in the medium increased the force of contraction of right ventricular papillary muscles, and the left ventricular pressure. Phenylephrine also enhanced the force of contraction in the presence of $Mg^{2+}-free$ medium. ${\alpha}_1-Agonists$ such as phenylephrine and methoxamine were found to induce $Mg^{2+}$ efflux in both perfused hearts and myocytes. These effects were blocked by prazosin, an ${\alpha}_1-adrenoceptor$ antagonist. The $Mg^{2+}$ influx could also be induced by phenylephrine and R59022, a diacylglycerol kinase inhibitor. In the presence of protein kinase C(PKC) inhibitors, phenylephrine produced an increase in $Mg^{2+}$ efflux from perfused hearts. Furthermore, $Mg^{2+}$ efflux by phenylephrine was amplified by phorbol 12-myristate 13-acetate(PMA). This enhancement of $Mg^{2+}$ efflux by PMA was blocked by prazosin in perfused hearts. By contrast, the $Mg^{2+}$ influx could be induced by verapamil, nifedipine, ryanodine in perfused hearts, but not in myocytes. $W^7$, a $Ca^{2+}$/calmodulin antagonist, completely blocked the phenylephrine-induced $Mg^{2+}$ efflux in perfused hearts. In conclusion, $Mg^{2+}$ is responsible for the cardiac activity associated with ${\alpha}_1-adrenoceptor$ stimulation. The mobilization of $Mg^{2+}$ is decreased or increased by ${\alpha}_1-adrenoceptor$ stimulation in guinea pig hearts. These responses may be related specifically to the respective pathways of signal transduction. A decrease in $Mg^{2+}$ efflux by ${\alpha}_1-adrenoceptor$ stimulation in hearts can be through PKC dependent and intracellular $Ca^{2+}$ levels.

  • PDF

Protein Tyrosine Phosphatase N1 Gene Variants Associated with Type 2 Diabetes Mellitus and Its Related Phenotypes in the Korean Population

  • Hong, Kyung-Won;Jin, Hyun-Seok;Lim, Ji-Eun;Ryu, Ha-Jung;Ahn, Youn-Jhin;Lee, Jong-Young;Han, Bok-Ghee;Shin, Hyoung-Doo;Cho, Nam-Han;Shin, Chol;Woo, Jeong-Taek;Park, Hun-Kuk;Oh, Berm-Seok
    • Genomics & Informatics
    • /
    • 제6권3호
    • /
    • pp.99-109
    • /
    • 2008
  • Protein phosphorylation at tyrosine residues is a key regulatory event that modulates insulin signal transduction. We studied the PTPN1 gene with regard to susceptibility to Korean type 2 diabetes mellitus (T2DM) and its related quantitative traits. A total of seven SNPs [g.36171G>A (rs941798), g.58166G>A (rs3787343), g.58208A>G (rs2909270), g.64840C>T (rs754118), g.69560C>G (rs6020612), g.69866G>A (rs718050), and g.69934T>G (rs3787343)] were selected based on frequency (>0.05), linkage disequilibrium (LD) status, and haplotype tagging status. We studied the seven SNPs in 483 unrelated patients with type 2 diabetes (age: $64{\pm}2.8$ years, onset age: $56{\pm}8.1$ years; 206 men, 277 women) and 1138 nondiabetic control subjects (age: $64{\pm}2.9$; 516 men, 622 women). The SNP rs941798 had protective effects against T2DM with an odds ratio of 0.726 (C.I. $0.541{\sim}0.975$) and p-value=0.034, but none of the remaining six SNPs was associated with T2DM. Also, rs941798 was associated with blood pressure, HDL cholesterol, insulin sensitivity. rs941798 also has been associated with T2DM in previous reports of Caucasian-American and Hispanic-American populations. This is the first report that shows an association between PTPN1 and T2DM in the Korean as well as Asian population.

Effects of Joint Mobilization Techniques on the Joint Receptors (관절 가동운동이 관절 감수기에 미치는 영향)

  • Kim, Suhn-Yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • 제2권1호
    • /
    • pp.9-19
    • /
    • 1996
  • Type I, II, III are regarded as "true" joint receptors, type IV is considered a class of pain receptor. Type I, II and III mechanoreceptors, via static and dynamic input, signal joint position, intraarticular pressure changes, and the direction, amplitude, and velocity of joint movements. Type I mechanoreceptor subserve both static and dynamic physiologic functions. Type I are found primarily in the stratum fibrosum of the joint capsule and ligaments. Type I receptors have a low threshold for activation and are allow to adapt to changes altering their firing frequency. Type II receptors have a low threshold for activation. These dynamic receptors respond to joint movement. Type II receptors are thus termed rapidly adapting. Type II joint receptors are located at the junction of the synovial membrane and fibrosum of the joint capsule and intraarticular and extraarticular fat pads. Type III receptors have been found in collateral ligaments of the joints of the extremities. Morphologically similar to Golgi tendon organ. These dynamic receptors have a high threshold to stimulation and are slowly adating. Type IV receptors possess free nerve ending that have been found in joint capsule and fat pads. They are not normally active, but respond to extreme mechanical deformation of the joint as well as to direct chemical or mechanical irritation. Small amplitude oscillatory and distraction movements(joint mobilization) techniques are used to stimulate the mechanoreceptors that may inhibit the transmission of nociceptors stimuli at the spinal cord or brain stem levels.

  • PDF

A Study of Liquid Chromatographic Detection Method for Thiocarbamates by Using Photochemical Reaction (광화학 반응을 이용한 티오카바메이트류의 액체 크로마토그래피 검출법에 관한 연구)

  • Dai Woon Lee;Young Hun Park;Yong Wook Choi
    • Journal of the Korean Chemical Society
    • /
    • 제37권4호
    • /
    • pp.453-461
    • /
    • 1993
  • Detection method was developed using a simply designed photochemical reactor made of teflon coil and low pressure mercury lamp. This method of UV photolysis of analytes followed by UV, fluorescence and electrochemical detection was found to be useful for four thiocarbamates. Analytes eluting from the column are irradiated with a high flux of 254 nm UV light, so that they change to either fluorescent active forms or highly electrochemically sensitive products. Appling this technique to the UV detection, thiocarbamates were converted into long wavelength absorbing products upon UV irradiation. In fluorescence detector four thiocarbamates are not detected at nonirradiated condition but fluorescence signals of MPTC, CPTC photolysates are appeared after irradiation with UV light. The electrochemical detection for the determination of thiocarbamates was enhanced up to 5∼20 fold signal after UV irradiation, compared to that of the nonirradiated. The detection limit of thiocarbamates on electrochemical detector was 13.3∼0.02 ng under pH 7.0, ionic strength $0.5{\times}10^{-2}$ M, phosphate buffer solution. Adducts produced by reaction of photolysates and OPA-MERC in the reaction coil were monitored at 425 nm with fluorescence detector, and one of the photolysates was primary amine.

  • PDF

A Study on Feedback Queue Generation Method in Police Motorcycle Simulator System (경찰 오토바이 시뮬레이터 시스템에서 피드백 큐 생성 방법에 관한 연구)

  • Ahn, Dong-Hyuk;Cho, Sung-Hyun;Jeong, Yang-Kwon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • 제13권4호
    • /
    • pp.827-836
    • /
    • 2018
  • In this study, we developed a PC - based motorcycle simulator based on the development technology of a virtual patrol motorcycle training system. This simulator has been developed to be applied to a variety of fields such as driving training for beginners, driver factor research, and system development such as ABS, which can be seen in advanced models. The weight of the motorcycle operated by the patrol guards is more than 400Kg. There is a lot of risk due to the nature of work without prior practice. Therefore, we implemented a study on the untilization of physical stress and temporal pressure in emergency situations. In order to get a feeling that the motorcycle simulator is operating in real-life, it is important that the mutual reliable signal transmission and operation feel between the driver and the simulator. In order to achieve this, we developed a system that can apply the sub-systems of the actual vehicle to the motorcycle simulator in order to generate the same operation feeling as the actual vehicle. Based on these results, we have developed a method of generating a feedback queue.

Development of analytical method for the isotope purity of pure D2 gas using high-precision magnetic sector mass spectrometer

  • Chang, Jinwoo;Lee, Jin Bok;Kim, Jin Seog;Lee, Jin-Hong;Hong, Kiryong
    • Analytical Science and Technology
    • /
    • 제35권5호
    • /
    • pp.205-211
    • /
    • 2022
  • Deuterium (D) is an isotope with one more neutron number than hydrogen (H). Heavy elements rarely change their chemical properties with little effect even if the number of neutrons increases, but low-mass elements change their vibration energy, diffusion rate, and reaction rate because the effect cannot be ignored, which is called an isotope effect. Recently, in the semiconductor and display industries, there is a trend to replace hydrogen gas (H2) with deuterium gas (D2) in order to improve process stability and product quality by using the isotope effect. In addition, as the demand for D2 in industries increases, domestic gas producers are making efforts to produce and supply D2 on their own. In the case of high purity D2, most of them are produced by electrolysis of heavy water (D2O), and among D2, hydrogen deuteride (HD) molecules are present as isotope impurities. Therefore, in order to maximize the isotope effect of hydrogen in the electronic industry, HD, which is an isotope impurity of D2 used in the process, should be small amount. To this end, purity analysis of D2 for industrial processing is essential. In this study, HD quantitative analysis of D2 for high purity D2 purity analysis was established and hydrogen isotope RM (Reference material) was developed. Since hydrogen isotopes are difficult to analyze with general gas analysis instrument, they were analyzed using a high-precision mass spectrometer (Gas/MS, Finnigan MAT271). High purity HD gas was injected into Gas/MS, sensitivity was determined by a signal according to pressure, and HD concentrations in two bottles of D2 were quantified using the corresponding sensitivity. The amount fraction of HD in each D2 was (4518 ± 275) μmol/mol, (2282 ± 144) μmol/mol. D2, which quantifies HD amount using the developed quantitative analysis method, will be manufactured with hydrogen isotope RM and distributed for quality management and maintenance of electronic industries and gas producers in the future.