Flow Analysis of Servo Valve (Servo valve의 유동해석)

  • Park, Hong-Beom;Sung, Hyung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1221-1225
    • /
    • 2008
  • In this paper, analysis of pressure and flow characteristics have been performed with a servo valve. A number of servo valve have been used in various applications including the inserting device, bearing transportation and welding machine. By analysis of flow and pressure gradient, technology can be obtained about optimal simulation of high response servo valve for competitiveness. Spool displacement and ratio of inlet/outlet pressure can give big effects to flow and pressure inside servo valve.

  • PDF

Optimization of Resistance Spot Welding Process Using Servo-gun System (서보건을 이용한 저항 점 용접 공정의 최적 용접 조건 설정에 관한 연구)

  • 백정엽;김태형;이종구;이세헌
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.679-682
    • /
    • 2002
  • Resistance spot welding using air gun has been used for joining the sheet metal in automotive manufacturing process. Although air gun has many advantages, it also has the limitation to control the pressure as a factor to improve weld quality. In this study, we apply servo gun using servo motor to resistance spot welding and find the relationship between welding pressure and welding quality. Trough the experiment to change welding pressure during the welding cycle, we can make it clear that the change of welding pressure is greatly influence on the welding quality. To get in a. using response surface methodology, drew out the optimal welding pressure profile for welding quality progresses. We made an optimal profile of welding pressure which improves welding quality using response surface methodology.

  • PDF

Fine Gap Control Using Pneumatic Servo System (공압서보시스템에 의한 미세 간극제어 시스템 설계)

  • 김동환;김영진;정대화
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.45-56
    • /
    • 2002
  • A pneumatic servo system requiring a fine gap control in a photo-electric sensor which is used for a LCD array detection device is introduced. The gap controlled by the pneumatic servo system remains within around 50~80 ${\mu}{\textrm}{m}$, and the system possesses an effect to eliminate undesirable particles on the LCD plate by blowing air out. The air flow rate is initially controlled by a servo valve and expanded by a booster valve, thus the controlled air pressure contributes to maintaining an appropriate gap between the LCD plate and photo-electric sensor An air floating plate of two degrees of freedom is designed and fabricated, and a fine tilting motion control is also implemented by assigning different gap commands. The pressure control and direct gap control are proposed, and each performance is verified experimentally.

Characteristic Analysis and Experiment of Pneumatic Servo Valve (공기압 서보밸브 특성해석 및 실험)

  • Kim, Dong-Soo;Lee, Won-Hee;Choi, Byung-Oh
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.967-973
    • /
    • 2004
  • Electro-pneumatic servo valve is an electro-mechanical device which converts electric signals into a proper pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristics, no air leakage at a null point, and can be fabricated at a low-cost. The first objective of this research is to design and to fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In order to design the mechanism of the servo valve optimally, the flow inside the valve depending upon the position of spool was analyzed variously, and on the basis of such analysis results, the valve mechanism, which was formed by combination of the spool and the sleeve, was designed and manufactured. And a tester for conducting an overall performance test was designed and manufactured, and as a result of conducting the flow rate test, the pressure test and the frequency test on the developed pneumatic servo valve.

  • PDF

Effect of Spool-Sleeve Geometry on Static Pressure Characteristics of Servo Valves (서보밸브 스풀-슬리브 형상공차가 압력 정특성에 미치는 영향 연구)

  • Kim, Sung Dong;Son, Sung Hoe;Ham, Young Bog
    • Journal of Drive and Control
    • /
    • v.13 no.1
    • /
    • pp.34-42
    • /
    • 2016
  • This study studied how the clearance, overlap and mismatch errors of spool-sleeve affect the static pressure characteristics of a servo valve. A computer simulation model was established as a direct acting servo valve and a series of simulations was conducted for various values of clearance, overlap and mismatch errors. Pressure gain decreased as the clearance increased. The overlap also affects the pressure gain and was similar to the effect of clearance. Asymmetry of the pressure plot got worse and worse as the mismatch error increased.

An Experimental Study on Static Characteristics of Servo Valves using Transmission Line Pressures (배관 압력을 이용한 서보밸브 정적 특성에 관한 실험적 연구)

  • Kim, Sung Dong;Joo, Byeol Jin;Yun, So Nam
    • Journal of Drive and Control
    • /
    • v.13 no.2
    • /
    • pp.42-50
    • /
    • 2016
  • The conventional technique to measure the hysteresis and the null of servo valves is defined in ISO 10770-1 and based on load flow signal of the servo valve. A new technique based on the transmission line pressures is suggested in this study. The new measuring method was verified through a series of experiments. No hysteresis was observed between the spool displacement and the transmission line pressures, load pressure or each chamber pressure. Some hysteresis was observed between valve input and pressures, which was found to be the same as those of load flow and spool displacement for the valve input. By using the chamber pressures, the hysteresis and the null are easier to measure than the load pressure or differential pressure between those two chamber pressures because the chamber pressures showed sharp edges.

Simulation and Experiment of Elastomer Seal for Pneumatic Servo Cylinder

  • Hur, Shin;Song, Kyung Jun;Woo, Chang Su
    • Elastomers and Composites
    • /
    • v.50 no.4
    • /
    • pp.251-257
    • /
    • 2015
  • The rubber seal is a part inserted into servo cylinder to keep the air pressure constant. In order for efficient movements of the servo cylinder, the frictional coefficient of the rubber seal needs to be minimized while the sealing is maintained. In this work the friction characteristics of rubber seal specimen are tested on metal plate at various conditions. The experimental conditions include roughness level, applied pressure, lubrication, and rubbing speed. The design of experiment approach is taken to assess the effect of each parameter. The nonlinear frictional response of the rubber is applied to the FEM model simulating the servo cylinder movement. The result demonstrates that precise optimization of the servo cylinder movement must be preceded by preliminary experiments coupled with the theory and FEM model.

A Study on the Frequency Response Signals of a Servo Valve (서보밸브의 주파수 응답 신호에 관한 연구)

  • Yun, Hongsik;Kim, SungDong
    • Journal of Drive and Control
    • /
    • v.18 no.1
    • /
    • pp.17-23
    • /
    • 2021
  • The flow signal or spool position signal is used to determine the dynamic characteristics of directional control valves. Alternatively, the signal of spool position or flow can be replaced with the velocity of a low friction, low inertia actuator. In this study, the frequency response of the servo valve equipped with a spool position transducer is measured with a metering cylinder. The input signal, spool displacement, load pressure, and velocity of the metering cylinder are measured, and the theoretical results from the transfer function analysis are verified. The superposition rule for magnitude ratio and phase angle was found to be always applicable among any signal type, and it was found that the load pressure signal is not appropriate for use as the signal for measuring the frequency response of a servo valve. It was confirmed that the frequency response of a servo valve using metering cylinder was similar to the results from a spool displacement signal. The metering cylinder used for measuring the frequency response of a servo valve should be designed to have sufficiently greater bandwidth frequency than the bandwidth frequency of the servo valve.