Safety Evaluations of Reservoir Embankment by Instrument System (계측시스템에 의한 저수지 제체의 안정성 평가)

  • Kim, Mi-Hyun;Lee, Dal-Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.6
    • /
    • pp.33-43
    • /
    • 2009
  • This study analyzed data on the pore water pressure, the ground water level, the horizontal displacement and the resistivity monitoring from instrument system, which is established to evaluate the safety in reservoirs. The pore water pressure in the embankment ranged from $0.035{\sim}1.116kg/cm^2$. The seepage that piping showed, as well as the leakage from the reservoirs are acceptable for the safety management of the reservoir. The maximum horizontal displacement and direction analyzed from the measured inclinometer data gives us very effective information to evaluate the safety in reservoirs. The resistivity monitoring technique, which is obtained on the reservoir crest, is an efficient tool to detect leakage zone. The safety index (SI) was predicted by the resistivity monitoring, and was evaluated to have a safety level of 0.8-1.0 at all reservoirs. Safety evaluations of reservoir through instrument systems are effective when studying the embankment, when the results of the instrument system have been analyzed compositively.

Safety Evaluations of Reservoir Embankment by Instrument System (계측시스템에 의한 저수지 제체의 안정성 평가)

  • Lee, Dal-Won;Kim, Mi-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.840-851
    • /
    • 2010
  • This study analyzed data on the pore water pressure, the ground water level, the horizontal displacement and the resistivity monitoring from instrument system, which is established to evaluate the safety in reservoirs. The pore water pressure in the embankment ranged from $0.035{\sim}1.116kg/cm^2$. The seepage that piping showed, as well as the leakage from the reservoirs are acceptable for the safety management of the reservoir. The maximum horizontal displacement and direction analyzed from the measured inclinometer data gives us very effective information to evaluate the safety in reservoirs. The resistivity monitoring technique, which is obtained on the reservoir crest, is an efficient tool to detect leakage zone. The safety index(SI) was predicted by the resistivity monitoring, and was evaluated to have a safety level of 0.8-1.0 at all reservoirs. Safety evaluations of reservoir through instrument systems are effective when studying the embankment, when the results of the instrument system have been analyzed compositively.

  • PDF

Chatter control and tool condition monitoring of turning processes using sound pressure (음압을 이용한 선삭공정에서의 채터제어 및 공구 상태감시)

  • Lee, S.I.;Chung, S.C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.11
    • /
    • pp.50-57
    • /
    • 1997
  • In order to make unmanned machining systems with satisfactory performances, it is necessary to incorporate appropriate condition monitoring systems in the machining workstations to provide the required intelligence of the expert. This paper deals with condition monitoring for chatter, tool wear and breakage during turning operation. To develop economic sensing and identiffication methods for turning processes, sound pressure measurement and digital signal processing technique were proposed. We suppressed chatter by stability control methodology, which was studied through manipulation of spindle speeds regarding to chatter frequencies. It was shown that tool wear and fracture were identified and to be estimated by using the wear indices. The validity of the proposed system was confirmed through the large number of cutting tests.

  • PDF

Back Tracing Calculation Method for the Leakage Detection in Water Distribution System (상수관망에서 누수탐지를 위한 역추적계산법)

  • Kwon, Hyuk Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.611-619
    • /
    • 2013
  • In this study, Back Tracing Calculation Method was developed to determine the leakage location and leakage amount. Previously developed determination method of monitoring location and newly developed Back Tracing Calculation Method were applied to the sample pipe network and real size pilot plant. After leakage was assumed in the pilot plant, leakage location and leakage amount could be traced by Back Tracing Calculation Method. From the results, it was found that Back Tracing Calculation Method can be applied for the leakage detection in water distribution system. Furthermore, this method can be applied for the pressure management or leakage detection as a pressure control method in water distribution system.

Long-term Monitoring System for Ship's Engine Performance Analysis Based on the Web (선박엔진성능분석용 웹기반 장기모니터링시스템 구현)

  • Kwon, Hyuk-Joo;Yang, Hyun-Suk;Kim, Min-Kwon;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.483-488
    • /
    • 2015
  • This paper implements a long-term monitoring system (LMS) for ship's engine performance analysis (SEPA) based on the web, for the purpose of the communication speed and engine maintenance. This system is composed of a simulator, monitoring module with a multi channel A/D converter, monitoring computer, network attached storage (NAS), RS485 serial and wireless internet communication system. The existing products monitor the information transmitted from pressure sensors installed in the upper parts of each of engines in the local or web computer, but have a delay in the communication speed and errors in long-term monitoring due to the large volume of sampling pressure data. To improve these problems, the monitoring computer saves the sampling pressure data received from the pressure sensors in NAS, monitors the long-term sampling data generated by the sectional down sampling method on a local computer, and transmits them to the web for long-term monitoring. Because this method has one tenth of the original sampling data, it will use memory with small capacity, save communication cost, monitor the long-term sampling data for 30 days, and as a result, make a great contribution to engine maintenance.

TPMS Interference Suppression Based on Beamforming (Beamforming을 이용한 TPMS 간섭제거)

  • Hwang, Suk-Seung;Kim, Seong-Min;Park, Cheol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.2
    • /
    • pp.180-185
    • /
    • 2011
  • The TPMS(Tire Pressure Monitoring System) is an electronic system designed to display the air pressure inside the pneumatic tires and report real-time tire-pressure information to the driver of the vehicle, either via a gange, a pictogram display, or a simple low-pressure warning light. Although the data measured by TPMS sensor is transmitted to internal signal processer in a vehicle through wireless communication, the receiver may suffers from various interferences such as amateur radio station, RFID(Radio-Frequency IDentification) for controlling container, RKE(Remote Keyless Entry) signal, and so on. In this paper, we consider beamforming technology to suppress various high-power interference signals for the TPMS wireless communications. Also, we propose the proper data structure and antenna arrangement for the beamformer inside the vehicle. The performance for the interference suppression is illustrated by computer simulation example.

Development of a Patient Monitoring System Overall Architecture and Specifications (환자모니터링시스템의 개발 : 전체구조 및 기본사양)

  • 우응제;박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.17-24
    • /
    • 1997
  • We have developed a patient monitoring system including module-based bedside monitors, interbed network, central stations, clinical workstations, and DB servers. A bedside monitor with a color LCD can accommodate up to 3 module cases and 21 different modules. Six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmoyaph are provided as parameter modules. In a single bedside monitor, modules and a module controller communicate with IMbps data rate through an intrabed network based on RS-485 and HDU protocol. At the same time, it communicates with other bedside monitors and central stations through interbed network based on 1 OMbps Ethernet and TCP/IP protocol. Central stations using 20" color CRT monitors can be connected with many bedside monitors and they display 18 channels of waveforms simultaneously. Clinical workstations are used mainly for the review of patient datE In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we have developed a relational database server dedicated to the patient monitoring system. Software for bedside monitor, central station, and clinical workstation fully utilizes graphical user interface techniques and all functions are controlled by a rotate/push button on the bedside monitor arid a mouse on the central station and clinical workstation. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances.nces.

  • PDF

A Study on the Development of Optical-Fiber Water Leakage Sensing System (광파이버 누수센싱 시스템 개발에 관한 연구)

  • Kim, Y.B.
    • Journal of Power System Engineering
    • /
    • v.16 no.6
    • /
    • pp.86-91
    • /
    • 2012
  • A multi purpose environmental monitoring system has been developed as a commercially available standard using the techniques which are FBG(Fiber Bragg Grating), Hetero-core spliced fiber optic sensor and etc, for the purposes of monitoring large scaled structures and preserving natural environments. The monitoring system has been tested and evaluated in a possible outdoor condition in view of the full scaled operation at actual sites to be monitored. Additionally, the developed systems in the previous works conveniently provided us with various options of sensor modules intended for monitoring such physical quantities as displacement, distortion, pressure, binary states, and liquid adhesion. In this paper, we extend the previous results to a water leakage detection problem and develop a sensing system as a result. By the experimental study, it is verified that multi-point leakage detection is possible using single line optical fiber.

Ubiquitous Computing Technology Based Environmental Monitoring and Diagnosis System : Architecture and Case Study (유비쿼터스 컴퓨팅 기술 기반 환경 모니터링/진단 시스템의 아키텍처 및 사례 연구)

  • Yoon, Joo-Sung;Hwang, Jung-Min;Suh, Suk-Hwan;Lee, Chang-Min
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.36 no.4
    • /
    • pp.230-242
    • /
    • 2010
  • In this paper, an environmental monitoring and diagnosis system based on ubiquitous computing technology, shortly u-Eco Monitoring System, is proposed. u-Eco Monitoring System is designed to: 1) Collect information from the manufacturing processes via ubiquitous computing technology, 2) Analyze the current status, 3) Identify the cause of problem if detected by rule-based and case-based reasoning, and 4) Provide the results to the operator for proper decision making. Based on functional modeling, a generic architecture is derived, followed by application to a manufacturing system in iron and steel making industry. Finally, to show the validity of the proposed method, a prototype is developed and tested. The developed methods can be used as a conceptual framework for designing environmental monitoring and diagnosis system for industrial practices by which monitoring accuracy and response time for abnormal status can be significantly enhanced, and relieving operator pressure from manual monitoring and error-prone decision making.

Respiration Measurement System using Textile Capacitive Pressure Sensor (전기용량성 섬유 압력센서를 이용한 호흡측정 시스템)

  • Min, Se-Dong;Yun, Young-Hyun;Lee, Chung-Keun;Shin, Hang-Sik;Cho, Ha-Kyung;Hwang, Seon-Cheol;Lee, Myoung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.58-63
    • /
    • 2010
  • In this paper, we proposed a wearable respiration measurement system with textile capacitive pressure sensor. Belt typed textile capacitive pressure sensor approach of respiration measurement, from which respiration signatures and rates can be derived in real-time for long-term monitoring, are presented. Belt typed textile capacitive pressure sensor has been developed for this measurement system. the distance change of two plates by the pressure of motion has been used for the respiration measurement in chest area. Respiration rates measured with the textile capacitive pressure sensor was compared with standard techniques on 8 human subjects. Accurate measurement of respiration rate with developed sensor system is shown. The data from the method comparison study is used to confirm theoretical estimates of change in capacitance by the distance change. The current version of respiratory rate detection system using textile capacitive pressure sensor can successfully measure respiration rate. It showed upper limit agreement of $3.7997{\times}10^{-7}$ RPM, and lower limit of agreement of $-3.8428{\times}10^{-7}$ RPM in Bland-Altman plot. From all subject, high correlation were shown(p<0.0001). The proposed measurement method could be used to monitor unconscious persons, avoiding the need to apply electrodes to the directly skin or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using textile capacitive pressure sensor offers a promising possibility of convenient measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range and quality of the rate-finding, broadening the potential application areas of this technology.