• Title/Summary/Keyword: Pressure monitoring

Search Result 1,102, Processing Time 0.025 seconds

The utility of ambulatory blood pressure monitoring in obese children (소아 비만아에서 ambulatory blood pressure monitoring의 유용성)

  • Kim, Myung Jin;Song, Jin Young
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.6
    • /
    • pp.604-609
    • /
    • 2008
  • Purpose : Obesity in children and adolescence is highly correlated with adult obesity, which can provoke hypertension. Therefore, it is important to evaluate the blood pressure of obese children regularly. In this study, the results of ambulatory blood pressure monitoring (ABPM) in obese children and adolescents were evaluated. Methods : ABPM was conducted for selected patients who visited Handong University Sunlin Hospital from Feb. 1, 2006 to Dec. 1, 2007. The patients were classified into 3 groups: group 1 was normal, group 2 had normal casual blood pressure and a body mass index over the 95th percentile, and group 3 had high casual blood pressure over 120/80 mm Hg and a body mass index over the 95th percentile. Systolic and diastolic 24-hour blood pressure was measured, including both day and night. Results : There were 49 patients in the study. The results showed a significant difference for average systolic blood pressure between the three groups ($105.1{\pm}4.7$, $111.0{\pm}7.1$, $117.8{\pm}6.6mmHg$, P<0.001), but for average diastolic blood pressure only between groups 1 and 3 ($69.1{\pm}5.3$, $77.9{\pm}6.3mmHg$, P=0.001). In the daytime, only groups 1 and 3 showed a statistically significant difference for systolic and diastolic blood pressure. During the night the systolic pressure of group 3 was significantly higher than the other groups, but the diastolic pressure of group 3 was only higher than that group 1. No statistical difference was found in night dips among the groups. Conclusion : Ambulatory blood pressure monitoring in children and adolescents showed statistically higher blood pressure in obese patients with high casual blood pressure.

Development of Maintenance Effectiveness Monitoring Program based on Design Characteristics for New Nuclear Power Plant (신규원전의 설계특성 기반 정비효과성감시 프로그램 개발)

  • Yeom, Dong-Un;Hyun, Jin-Woo;Song, Tae-Young
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.1
    • /
    • pp.25-32
    • /
    • 2012
  • Korea Hydro & Nuclear Power Co. (KHNP) has developed and implemented the maintenance effectiveness monitoring (MR) programs for the operating nuclear power plants. The MR program is developed by reflecting design characteristics of the operating nuclear power plants to monitor the plant performance for improving the safety and reliability. Recently, KHNP has built a new nuclear power plant, and developed the MR program to establish the advanced maintenance system by reflecting unique design characteristics based on the OPR1000 standard model. So, the MR program developed in this study has another characteristics in comparison with the OPR1000 standard model, and we will verify the suitability of the MR program through evaluating initial performance of the plant. The safety and reliability of the new plant will be improved by developing and implementing the MR program.

Safety Evaluations of Reservoir Embankment by Instrument System (계측시스템에 의한 저수지 제체의 안정성 평가)

  • Kim, Mi-Hyun;Lee, Dal-Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.6
    • /
    • pp.33-43
    • /
    • 2009
  • This study analyzed data on the pore water pressure, the ground water level, the horizontal displacement and the resistivity monitoring from instrument system, which is established to evaluate the safety in reservoirs. The pore water pressure in the embankment ranged from $0.035{\sim}1.116kg/cm^2$. The seepage that piping showed, as well as the leakage from the reservoirs are acceptable for the safety management of the reservoir. The maximum horizontal displacement and direction analyzed from the measured inclinometer data gives us very effective information to evaluate the safety in reservoirs. The resistivity monitoring technique, which is obtained on the reservoir crest, is an efficient tool to detect leakage zone. The safety index (SI) was predicted by the resistivity monitoring, and was evaluated to have a safety level of 0.8-1.0 at all reservoirs. Safety evaluations of reservoir through instrument systems are effective when studying the embankment, when the results of the instrument system have been analyzed compositively.

Remote Patient Monitoring Service through World-Wide Web (Web을 통한 원격 환자 모니터링 서비스)

  • Lee, H.S.;Park, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.188-191
    • /
    • 1997
  • In this paper, we present a real-time remote patient monitoring service through world-wide web, which allows the medical doctor to monitor his patients in remote sites using popular web browsers. The real-time service consists of two services: Patient Locator Service (PLS) and Vital Sign Monitoring Service (VSMS). The PLS provides the information of patients currently being monitored. The VSMS allows the user to observe a stream of vital sign data of a specific patient. The vital sign data include ECG, respiration, temperature, $SPO_2$, invasive blood pressure and non-invasive blood pressure.

  • PDF

Safety Evaluations of Reservoir Embankment by Instrument System (계측시스템에 의한 저수지 제체의 안정성 평가)

  • Lee, Dal-Won;Kim, Mi-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.840-851
    • /
    • 2010
  • This study analyzed data on the pore water pressure, the ground water level, the horizontal displacement and the resistivity monitoring from instrument system, which is established to evaluate the safety in reservoirs. The pore water pressure in the embankment ranged from $0.035{\sim}1.116kg/cm^2$. The seepage that piping showed, as well as the leakage from the reservoirs are acceptable for the safety management of the reservoir. The maximum horizontal displacement and direction analyzed from the measured inclinometer data gives us very effective information to evaluate the safety in reservoirs. The resistivity monitoring technique, which is obtained on the reservoir crest, is an efficient tool to detect leakage zone. The safety index(SI) was predicted by the resistivity monitoring, and was evaluated to have a safety level of 0.8-1.0 at all reservoirs. Safety evaluations of reservoir through instrument systems are effective when studying the embankment, when the results of the instrument system have been analyzed compositively.

  • PDF

Development of Ultrasonic Active Fiber Sensor for Structural Health Monitoring (구조물 안전진단을 위한 초음파능동형광섬유 센서의 개발)

  • Lim, Seung-Hyun;Lee, Jung-Ryul;Oh, Il-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.747-752
    • /
    • 2008
  • Fiber-guided sensor system using a generator and a receiver can detect the amplitude of load or pressure. However, this type of sensor can show some difficulties in detecting the location of damages and pressure loadings. To overcome this weakness of this type, the ultrasonic active fiber sensor, which has an integrated ultrasonic generator and sensing part, was developed in this study. By using this sensor system, the location of mechanical loads can be exactly detected. Moreover, the ultrasonic active fiber sensor is more cost-effective than an ultrasonic fiber sensor using two piezoelectric transducers which are used as a generator and a receiver, respectively. Two applications of the ultrasonic active fiber sensor are demonstrated: cure monitoring of lead and measurement of liquid level. Present results showed that the active fiber sensor can be applied for various environmental sensing.

  • PDF

Development of a Module-Based Bedside Monitor for Patient Monitoring (모듈형 환자 모니터의 개발)

  • 우응제;박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.133-146
    • /
    • 1997
  • In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases, each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO with plethysmograph.raph.

  • PDF

In-situ Monitoring of Matric Suctions in a Weathered Granite Soil Slope (풍화화강토 사면에서 강우로 인한 모관흡수력 변화에 대한 실험 연구)

  • 이인모;조우성;김영욱;성상규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.509-516
    • /
    • 2002
  • Rainfall-induced landslides in a weathered granite soil slope have mostly relative shallow slip surfaces above the groundwater table The pore-water pressure of soil above the groundwater table is usually negative. This negative pore-water pressure(or matric suction) has been found to make a large contribution to the slope stability. Therefore, the variation of in-situ matric suction profiles with time in a soil slope should be understood. In this study, a field measurement program was carried out from June to August, 2001 to monitor in-situ matric suctions and volumetric water contents in a weathered granite soil slope. The influence of climatic conditions on the variation of in-situ matric suctions could be found to decrease rapidly with depth. It could be found that decrement of matric suction induced by precipitation is affected not only by the amount and duration of rainfalls but also by the initial matric suction just prior to rainstorms. The soil-water characteristic from the field monitoring tends toward the wetting path of SWCC obtained from the laboratory test.

  • PDF

Predictive Maintenance Plan based on Vibration Monitoring of Nuclear Power Plants using Industry 4.0 (4차 산업기술을 활용한 원전설비 진동감시기반 예측정비 방안)

  • Do-young Ko
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.19 no.1
    • /
    • pp.6-10
    • /
    • 2023
  • Only about 10% of selected equipment in nuclear power plants are monitored by wiring to address failures or problems caused by vibration. The purpose is primarily for preventive maintenance, not for predictive maintenance. This paper shows that vibration monitoring and diagnosis using Industrial 4.0 enables the complete predictive maintenance for all vibrating equipments in nuclear power plants with the convergence of internet of things; wireless technology, big data through periodic collection and artificial intelligence. Predictive maintenance using wireless technology is possible in all areas of nuclear power plants and in all systems, but it should satisfy regulatory guides on electromagnetic interference and cyber security.

Development of a Portable Total-phosphorus Monitoring System for Preventing Eutrophication in Advance (부영양화 사전 예방을 위한 휴대용 총인 모니터링 시스템 개발)

  • Jung, Dong Geon;Kim, Seung Deok;Kwon, Soon Yeol;Lee, Jae Yong;Kim, Yu Seong;Lee, Junyeop;Kim, JaeKeon;Kim, Sae-Wan;Kong, Seong Ho;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.342-347
    • /
    • 2020
  • In this study, a portable total-phosphorus (TP) monitoring system utilizing a photocatalytic-reaction-based pretreatment method is proposed, fabricated, and characterized. Commercial TP monitoring systems are only used in laboratories because of their complex monitoring procedure, bulk-size, and high-cost. In particular, pretreatment in commercial TP monitoring systems is performed at high temperatures (> 120 ℃) and pressure (> 1.1 kg cm-2) making it difficult to minimize the scale of the systems. The proposed TP monitoring system employs a pretreatment method with a photocatalytic reaction; thus, its size can be reduced, as photocatalytic reactions occur at room temperature and atmospheric pressure. Analytes with various TP concentrations are pretreated using the proposed portable TP monitoring system and are quantitatively measured with an LED and a photodiode.