• Title/Summary/Keyword: Pressure maintenance

Search Result 601, Processing Time 0.028 seconds

Non-contact Impact-Echo Based Detection of Damages in Concrete Slabs Using Low Cost Air Pressure Sensors (저비용 음압센서를 이용한 콘크리트 구조물에서의 비접촉 Impact-Echo 기반 손상 탐지)

  • Kim, Jeong-Su;Lee, Chang Joon;Shin, Sung Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.3
    • /
    • pp.171-177
    • /
    • 2011
  • The feasibility of using low cost, unpowered, unshielded dynamic microphones is investigated for cost effective contactless sensing of impact-echo signals in concrete structures. Impact-echo tests on a delaminated concrete slab specimen were conducted and the results were used to assess the damage detection capability of the low cost system. Results showed that the dynamic microphone successfully captured impact-echo signals with a contactless manner and the delaminations in concrete structures were clearly detected as good as expensive high-end air pressure sensor based non-contact impact-echo testing.

Comparison of Cardiopulmonary Effects and Recovery between Total Intravenous Anesthesia with Propofol and Volatile Induction/maintenance Anesthesia with Isoflurane in Beagle Dogs (비글견에서 Propofol 완전정맥마취와 Isoflurane 휘발성 유도/유지 마취 시 심폐기능과 회복의 비교)

  • Lee Soo-Han
    • Journal of Veterinary Clinics
    • /
    • v.22 no.3
    • /
    • pp.259-263
    • /
    • 2005
  • To compare cardiopulmonary effects and recovery between total intravenous anesthesia (TIVA) with propofol (PRO group, n=5) and volatile induction/maintenance anesthesia (VIMA) with isoflurane (ISO group, n=5), we investigated changes of heart rate, $SpO_2$, arterial pressure, rectal temperature and respiratory rate during 60 minute anesthesia and 40 minute recovery period in beagle dogs, and investigated recovery (extubation, head lift, sternal position and righting) after 60 minute anesthesia. Rectal temperature was significantly low in ISO group (p<0.05) from 10 to 100 minute. Heart rate was significantly low in ISO group (p<0.05) at 40, 50, 60 minute. Respiratory rate was significantly low in PRO group (p<0.05) at induction and 70 minute. $SpO_2$ tendency was similar. Systolic arterial pressure (SAP) was significantly low in ISO group (p<0.05) at induction and during anesthesia. Recovery was similar in two groups. We concluded that TIVA with propofol is useful in stabilizing rectal temperature and arterial pressure during anesthesia and provide fast and stable recovery.

Stability Analysis and Reinforcement of Large Excavated Slope considering Precipitation Infiltration in Rainy Season (강우침투로 인한 대절취사면의 붕괴안정성검토 및 대책)

  • Chun, Byung-Sik;Choi, Hyun-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.1
    • /
    • pp.101-110
    • /
    • 2000
  • In case heavy rainfall is a key factor of slope failure, the failure zone is usually developed within the depth of 3~5m from the ground surface regardless of the location of the watertable. If rainfall is taken into consideration, it is general that the slope stability analysis is carried out under the assumption that the cut slope is saturated to the slope surface or the watertable elevates to a certain height so that ${\gamma}_{sat}$, the unit weight of saturated soil, is used. However, the analysis method mentioned above can't exactly simulate the variation of pore water pressure in the slope and yields different failure shape. The applicability of slope stability analysis method considering the distribution of pore water pressure within the slope with heavy rainfalls, was checked out after the stability analysis of a lage-scale cut slope in a highway construction site, where surface failure occurred with heavy rainfalls. An appropriate slope stabilization method is proposed on the base of the outcome of the analysis.

  • PDF

A Basic Study on the Standardization of Epoxy Injection on Concrete Structure Crack (콘크리트 구조물 균열에 에폭시 주입의 표준화를 위한 기초적 연구)

  • Baek, Jong-Myeong;Jang, Seog-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.115-122
    • /
    • 2006
  • Repairing concrete structures depended on only technician' experience without quality test standards would have problems. For solving those problems, this paper has analyzed the relations between injection quantify and crack width, injection time and crack width, injection pressure and crack width, injection pressure/time and crack width, injection quantity and structure size, injection quantify and individual crack Position, injection time and crack width/structure thickness. The data gained from this analysis would be helpful for systematic quality control of repairing concrete structures.

Development of A smart pressure transducer (지능형 압력 변환기 개발)

  • Park, Chan-Won;Min, Nam-Gi
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.8
    • /
    • pp.941-947
    • /
    • 1999
  • As pressure transducers are employed in many fields such as production facilities, test facilities vehicles and industrial machinery, there is an increasing need for high precision measurement of pressure without any calibration or maintenance. In this paper, we discuss the development of a smart thin film pressure transducer which is highly suitable for a precise measurement of pressure. The smart functions include automatic zero tracking, automatic span adjustment, temperature compenstion, continuous self-diagnostics for faults (open strain gages, abnormal data, incorrect A/D conversion, and overpressure), data memory and multi-drop communication with PC

  • PDF

The Effects of the Individual Application of Low Sodium Dialysate on Weight Gain, Blood Pressure, and Intradialytic Side Effects in Patients on Maintenance Hemodialysis (개별적 저나트륨 투석액 적용이 혈액투석 환자의 체중증가, 혈압 및 투석 중 부작용에 미치는 효과)

  • Song, Ji Sook;Kim, Eun Sook;Lee, Yu Na
    • Journal of Korean Clinical Nursing Research
    • /
    • v.19 no.1
    • /
    • pp.45-56
    • /
    • 2013
  • Purpose: The purpose of this study is to identify the effect of low sodium dialysate (LSD) rather than conventional dialysate on interdialytic weight gain (IWG), blood pressure (BP), and intradialytic side-effects (ISEs) in patients on maintenance hemodialysis (HD). Methods: The study was performed in 43 patients, who were treated in the university hospital over 8 weeks. Each participant's serum sodium set point was measured using dialysate sodium 140 mEq/L during the first 4 weeks. For the next 4 weeks dialysate sodium concentrate (134,136,and138 mEq/L) was provided to each participant but only to an experimental group (EG) (n=22) based on the individual set point, although 140 mEq/L dialysate was given to all of the control group (CG) (n=21). Consequently, outcomes including IWG, BP, and ISE were evaluated. Results: In EG, difference of pre-HD SBP (p=.047) and post-HD serum sodium (p=.006) were significantly decreased compared to CG. Also, ISEs was not more frequent in EG. However, the differences were not statistically significant, IWG (kg & %), pre-HD DBP, post-HD SBP & DBP, and serum osmolality in EG. Conclusion: Individual application of LSD in patients on maintenance hemodialysis is beneficial to decrease pre-HD SBP and post-HD serum sodium without increasing ISE. Therefore, LSD can be better treatment than conventional dialysate.

The Impact of Facebook Access Motivation on Offline Interpersonal Relationship Change and Continuance Usage Intention of Facebook (페이스북 접속동기가 사용후 대인관계 변화와 페이스북의 지속적 사용의도에 미치는 효과)

  • Lee, Eunhee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.2
    • /
    • pp.97-105
    • /
    • 2018
  • This study examined the psychological process in which Facebook access motivation impact upon offline interpersonal relationship change and continuance usage intention of Facebook, A questionnaire was administered to 420 college students in the Busan, and Gyeongnam provinces This research resulted in a number of key findings: First, Facebook access motivation of maintenance of social connection had a positive influence on offline interpersonal relationship change. Second, Facebook access motivation of social pressure from others had a positive influences on offline interpersonal relationship change. Third, Facebook access motivation of habitual use had a positive influences on continuance usage intention of Facebook, Fourth, Offline interpersonal relationship change mediates between Facebook access motivation of maintenance of social connection & Facebook access motivation of social pressure from others and continuance usage intention of Facebook, This study reveals that, Facebook access motivation of maintenance of social connection and Facebook access motivation of social pressure from others were a significant predictors of offline interpersonal relationship change, and Facebook access motivation of maintenance of social connection and Facebook access motivation of social pressure from others indirectly affected continuance usage intention of Facebook through the offline interpersonal relationship change.

The Fusion Characteristic Varying with Butt Fusion Times for Polyethylene Pipe (PE배관 버트 융착 시간에 따른 융착 특성 변화)

  • 이영순;장영오
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.199-205
    • /
    • 1998
  • Butt fusions were practiced with butt fusion in the various conditions of fusion temperatures, pressure and time, and the tests of tesile strength, breaking water pressure and fusion features were also practiced so that the reliability of the butt fusion and the fittets fusion condition may be closely examined. And the width, height and thickness of the beads were also closely measured. The fittest fusion result was achieved in the condition of the temperature of $210^{\circ}C$, heating time hight pressure of 14 seconds on the pressure of $1.5kg/cm^2$, heating time hight pressure of 100 seconds and pressure buid-up time of 11 seconds. And in case of the temperature of $250^{\circ}C$, the fittest fusion result was showed in the condition of the heating time hight pressure of 3 seconds on the pressure of 1.0$kg/cm^2$, the heating time low pressure variable of 100 seconds. heating time hight pressure of 14 seconds and the heating maintenance of around 60 seconds. The result of breaking water pressure test of a test piece fusion in the fittest fusion condition was that the fusion condition of the PE pipe showed a good stability and hight reliance. Through this test, it is proved that the temperature of fusion PE pipes can be increased to $250^{\circ}C$ from $210^{\circ}C$. And it can be expected that the above fusion method greatly helps to reduce the fusion time.

  • PDF

Review of Membrane Tension Maintenance System for Membrane Structures through Membrane Tension Measurement (막장력 측정을 통한 막구조물의 장력 유지관리 시스템 검토)

  • Jin, Sang-Wook;Shon, Su-Deok;Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.39-45
    • /
    • 2016
  • Membrane structure is a system that is stabilized by maintaining a tensile state of the membrane material that originally cannot resist the bending or pressure. Also, it is a system that allows the whole membrane structure to bear external loads caused by wind or precipitation such as snow, rain and etc. Tension relaxation phenomenon can transpire to the tension that is introduced to the fabric over time, due to the innate characteristics of the membrane material. Thus, it is important to accurately understand the size of the membrane tension after the completion of the structures, for maintenance and management purposes. The authors have proposed the principle of theoretically and indirectly measuring the tension by vibrating the membrane surface with sound waves exposures against the surface, which is compartmentalized by a rectangular boundary, and by measuring the natural frequency of the membrane surface that selectively resonates. The authors of this paper measured the tension of preexisting membrane structure for its maintenance by using the developed portable measurement equipment. Through analyzing the measurement data, the authors review the points that should be improved and the technical method for the new maintenance system of membrane tension.

A design approach of integral-abutment steel girder bridges for maintenance

  • Kim, WooSeok;Jeong, Yoseok;Lee, Jaeha
    • Steel and Composite Structures
    • /
    • v.26 no.2
    • /
    • pp.227-239
    • /
    • 2018
  • Integral abutment bridges (IABs) have no joint across the length of bridge and are therefore also known as jointless bridges. IABs have many advantages, such as structural integrity, efficiency, and stability. More importantly, IABs have proven to be have both low maintenance and construction costs. However, due to the restraints at both ends of the girder due to the absence of a gap (joint), special design considerations are required. For example, while replacing the deck slabs to extend the service life of the IAB, the buckling strength of the steel girder without a deck slab could be much smaller than the case with deck slab in place. With no deck slab, the addition of thermal expansion in the steel girders generates passive earth pressure from the abutment and if the applied axial force is greater than the buckling strength of the steel girders, buckling failure can occur. In this study, numerical simulations were performed to estimate the buckling strength of typical steel girders in IABs. The effects of girder length, the width of flange and thickness of flange, imperfection due to fabrication and construction errors on the buckling strengths of multiple and single girders in IABs are studied. The effect of girder spacing, span length ratio (for a three span girder) and self-weight effects on the buckling strength are also studied. For estimation of the reaction force of the abutment generated by the passive earth pressure of the soil, BA 42/96 (2003), PennDOT DM4 (2015) and the LTI proposed equations (2009) were used and the results obtained are compared with the buckling strength of the steel girders. Using the selected design equations and the results obtained from the numerical analysis, equations for preventing the buckling failure of steel girders during deck replacement for maintenance are presented.