• 제목/요약/키워드: Pressure filtration

검색결과 356건 처리시간 0.026초

선체 표면 공사시 발생하는 분진 수거 장치 개발에 관한 연구 (A Study on the Development of Dust Collection System for Hull Repair)

  • 여석준
    • 동력기계공학회지
    • /
    • 제8권2호
    • /
    • pp.31-38
    • /
    • 2004
  • The main purpose of this study is to investigate the characteristics of hybrid collection system combined with centrifugal force of cyclone and filtration of bag filter in one unit system. The experiment and numerical simulation are executed for the analysis of collection efficiency and pressure drop characteristics of hybrid system in comparison with those of a general fabric bag filter with the various experimental parameters such as inlet velocity(filtration velocity), dust concentration and dust type, etc.. In present system, dust particles tangentially coming into the system body are controlled by the centrifugal force effect, and the next collection is made out by the filtration mechanism in the fabric filter media. Therefore, the effective first collection causes the decrease of dust loading on the fabric filter, and it presents quite a lower pressure drop of fabric filter than that of a general fabric filter. At the inlet velocity, $21{\sim}27m/sec$ and inlet concentration(fly ash) $300mg/m^3$, pressure drops through the filter media of hybrid system are shown lower as $10{\sim}22mmH_2O$ comparing to those($17{\sim}33mmH_2O$) of a general fabric bag filter.

  • PDF

Characterization of depth filter media for gas turbine intake air cleaning

  • Park, Young Ok;Hasolli, Naim;Choi, Ho Kyung;Rhee, Young Woo
    • 한국입자에어로졸학회지
    • /
    • 제5권4호
    • /
    • pp.159-170
    • /
    • 2009
  • A depth filter medium was newly designed in order to achieve high collection of dust and low pressure drop in this work. Multilayer depth filter media consist of an upstream layer of highly porous structure which allows particles to pass through and to follow by one or more downstream layers to hold the particles inside the media. For each filter media, flat sheet and pleated module were made of newly developed depth filter media and filter media of commercial products. Commercial depth filter cartridge for gas turbine air intake cleaning were used as reference for filtration area and pleat geometry of pleated modules. This work attempts to evaluate and compare the newly developed depth filter medium and two commercial filter media in terms of filtration parameters such as air permeability, initial pressure drop, particle retention and pressure drop variation with dust loading. According to the close examination the newly developed depth filter showed better performance compared to the commercial depth filter media.

  • PDF

다순환 여과시험에 의한 자동차용 연료필터의 성능 평가 (Performance Evaluation of an Automotive Fuel Filter by Multi-Pass Filtration Test)

  • 이재천;장지현
    • 한국자동차공학회논문집
    • /
    • 제10권6호
    • /
    • pp.219-226
    • /
    • 2002
  • Filtration performance of an automotive fuel filter was evaluated based on the theory of Beta ratio. This study also introduced the fuel components' contamination performance test stand incorporating the multi-pass filtration test circuit. The theoretical basis of multi-pass test and test procedure were described in detail. The specification of commercial fuel filter currently available was just the maximum pressure drop across the filter assembly and the holding capacity of contaminants. However, test results revealed that the fuel filter tested could not maintain consistent Beta ratio, that is filtration efficiency, although it had the holding capacity close to the specification. Hence the Beta ratio should be specified in service life. The results also showed that filtration system model should be refined including desorption ratio to estimate the variable Beta ratio in the test.

회분식 막여과 시스템에서 약품역세가 여과성능에 미치는 영향 (The Effect of Chemical Backwash on Filtration Performance of Batch Membrane Filtration System)

  • 김관엽;이의종;권진섭;김형수
    • 상하수도학회지
    • /
    • 제23권6호
    • /
    • pp.855-864
    • /
    • 2009
  • The main object of this work was to determine the influence of periodic chemical backwash on filtration resistance in membrane filtration system. In this work Hermia's models were used to investigate the fouling mechanisms involved in the microfiltration of $0.45{\mu}m$ filtered sewage feed. Batch microfiltration experiments were performed at transmembrane pressure 0.4 bar and different feed SCOD concentration (9~67 mgSCOD/L). The results showed that the best fit to experimental data corresponded to the intermediate blocking model followed by the standard and complete blocking model for all the experimental conditions tested. From the simulation results of filtration performance, it was found that in order to maintain sustainable operation of membrane filtration system, irreversible foulant component accumulated continuously on membrane surface and/or pore must be effectively removed. In addition, it was verified that periodic chemical backwash using NaOCl or NaOH effectively improved filtration performance of membrane.

콜로이드 용액의 막여과에서 자연대류 불안정 흐름의 막오염 저감 효과 해석: 막힘여과 모델의 적용 (Analysis of Membrane Fouling Reduction by Natural Convection Instability Flow in Membrane Filtration of Colloidal Solution: Application of Blocking Filtration Model)

  • 김예지;염경호
    • 멤브레인
    • /
    • 제29권6호
    • /
    • pp.329-338
    • /
    • 2019
  • 알루미나 콜로이드 용액의 막여과에서 막모듈의 중력에 대한 경사각 변화로 유발된 자연대류 불안정 흐름(natural convection instability flow, NCIF)의 콜로이드 물질의 막오염 제어 효과를 정압(constant-pressure) 막여과 시 플럭스 증가와 정투과량(constant-flux) 막여과 시 막차압 감소 정도로 측정하고, 플럭스 결과를 막힘여과 모델로 해석하였다. 막모듈의 경사각이 0°에서 180°로 커지면 NCIF 유발이 증가하여 막오염 제어 효과가 커져 2시간의 막여과에서 플럭스는 최대 2.8배까지 증가하고, 막차압은 최대 85%까지 감소하였다. 막힘여과 모델을 적용하여 NCIF의 유발에 따른 플럭스 결과를 해석하여 운전 시간 15분 이내에서는 중간막힘모델 그 이후에는 케이크여과모델로 평가하는 것이 타당하였다. 막모듈 경사각 180°에서 유발된 NCIF는 15분 이내의 운전 초기에는 중간막힘 오염을 52% 감소시키고, 그 이후의 운전 시간에서는 케이크층 오염을 93% 감소시켰다. 따라서 막모듈에 유발된 NCIF의 주된 막오염 제어기작은 막표면에의 입자상 콜로이드 물질의 케이크층 형성을 억제시키는 것으로 평가하였다.

Purification During Crossflow Electromicrofiltration of Fermentation Broth

  • Park Young G.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제9권6호
    • /
    • pp.500-505
    • /
    • 2004
  • The present study was to investigate the purification of a fermentation broth by an electromicrofiltration membrane. Microfiltration runs with a crude and a centrifuged broth, with solution of particles recovered from centrifugation and with permeates from microfiltration experiments were thus compared. Microfiltration performances were governed by colloids and small particles that induced sharp initial flux declines. For these results, the evolution of the overall membrane resistance was increased by $80\%$ in comparison with the electromicrofiltration membrane. The main focus of this study was set on the enhancement of the filtrate flux by an electric field. This pressure electrofiltration leads to a drastic improvement of the filtration by $100\%$ and the filtration time was thereby reduced. Pressure electrofiltration serves as an inter­esting alternative to the cross-flow filtration and it effectively separates advantageous constitu­ents such as amino acids and biopolymers from a fermentation broth. They were equally main­tained during the microelectrofiltration, although they were significantly reduced by $45\%$ by the microfiltration without the application of an electric field. Accordingly, since the electrofiltration membrane was provided more permeability, this study experimentally demonstrates that the permeability inside a membrane can be controlled using an electric field.

저밀도 세라믹 필터의 고온 여과 성능시험에 관한 연구 (A Study on the High Temperature Filtration Performance Test of Low Density Ceramic Filters)

  • 이동섭;홍민선;최종인
    • 한국대기환경학회지
    • /
    • 제17권1호
    • /
    • pp.75-84
    • /
    • 2001
  • Hot gas filtration method via using ceramic filters is an evolving technology applicable to numerous industrial and air pollution control processes. Alumino silicate, organic and inorganic binders were the major raw materials in manufacturing ceramic filters. In this work, disc type ceramic filters(50$\phi$$\times$10t) were manufactured by vacuum forming processes using ceramic raw materials. The porosity and bulk density of disc type ceramic filers ranged from 86 to 89% and from 0.27 to 0.36 g/㎤, respectively. In this work disc type ceramic medium were tested utilizing coupon experimental apparatus. Disc type filters showed high collection efficiencies over 99.96% with Darchs law coefficients of 4.1$\times$10(sup)10~9.63$\times$10(sup)10/$m^2$ depending on mean pore sizes. In addition, filtration and detachment of ceramic filters turned out to be performed effectively using 10 cm/sec face velocity, 5 minutes filtration cycle, 100msec pulse jet valve opening time and 3 bar pulsing pressure.

  • PDF

고온 고압 집진을 위한 역세정 유동장의 특성에 관한 연구 (A Study on the Reverse Cleaning Flow Characteristics for High Temperature and High Pressure Filtration)

  • 김장우;정진도;김은권
    • 한국대기환경학회지
    • /
    • 제19권1호
    • /
    • pp.25-31
    • /
    • 2003
  • Ceramic filter has been demonstrated as an attractive system to improve the thermal efficiency and to reduce the effluent pollutants. Removal of particulates from the hot gas stream is very important in air pollution control. In particular, the elimination of the particulate matters discharged from a gas turbine at high temperature can prevent the corrosion inside the IGCC. In this study, a Lab. scale test and numerical simulation were carried out to comprehend the relationship between pulse jet pressure and recovery of pressure drop and to characterize the reverse cleaning flow through a ceramic fil-ter element under high temperature and high pressure. When the pulse-jet pressures were 2, 3 and 4 kg/$ extrm{cm}^2$, the cleaning effect increase of about 10~30% by recovery of pressure drop caused by pulse pressure. Cleaning effect at 45$0^{\circ}C$ was greater than that at 55$0^{\circ}C$ or 650$^{\circ}$ for the same pulse pressure. According to the result of the present simulation, high pressure has been formed in terminal and central regions in our models and temperature distribution caused by pulse air is to be uniform comparatively on inner surface of filter.

경험모델을 이용한 충격기류식 여과집진기의 적정 탈진압력 예측 (The Prediction of Optimal Pulse Pressure Drop by Empirical Static Model in a Pulsejet Bag Filter)

  • 서정민;박정호;임우택;강점순;조재환
    • 한국환경과학회지
    • /
    • 제21권5호
    • /
    • pp.613-622
    • /
    • 2012
  • A pilot-scale pulse-jet bagfilter was designed, built and tested for the effects of four operating conditions (filtration velocity, inlet dust concentration, pulse pressure, and pulse interval time) on the total system pressure drop, using coke dust from a steel mill factory. Two models were used to predict the total pressure drop according to the operating conditions. These model parameters were estimated from the 180 experimental data points. The empirical model (EM) with filtration velocity, areal density, inlet dust concentration, pulse interval time and pulse pressure shows the best correlation coefficient (R=0.971) between experimental data and model predictions. The empirical model was used as it showed higher correlation coefficient (R=0.971) compared to that of the Multivariate linear regression(MLR) (R=0.961). The minimum pulse pressure predicted by empirical model (EM) was 5kg/$cm^2$.

운전압력의 순환변화에 따른 알루미나 현탁액의 정밀여과 투과거동 (Permeation Behavior of Microfiltration Membrane by Alumina Colloidal Suspension under a Cyclic Variation in TMP)

  • 남석태;한명진
    • 멤브레인
    • /
    • 제21권1호
    • /
    • pp.13-21
    • /
    • 2011
  • 본 연구는 폴리에틸렌 정밀여과 막을 이용한 $Al_2O_3$ 콜로이드 현탁액의 운전압력 순환변화에 따른 투과거동을 검토하였다. 운전압력의 순환은 0.49에서 1.96 bar까지 증가시키는 증압운전 후 다시 0.49 bar로 감소시키는 감압운전으로 행하였다. 연속적으로 운전압력을 순환변화 시킨 결과, 증압운전과 감압운전의 투과유속이 서로 다른 이력(hysteresis)을 나타냈다. 현탁액의 투과저항은 감압운전의 경우가 증압운전의 경우보다 컸으며, 투과저항 증가율도 컸다. 막오염 형태는 증압운전과 감압운전 모두 운전초기에 케익오염이 강하게 나타났으며, 막오염의 크기는 감압운전의 오염이 증압운전의 오염보다 컸다.