Performance Test of Air Filter Media (필터여재의 성능평가)

  • Ahn, K.H.;Bae, G.N.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.417-426
    • /
    • 1994
  • Filter media performance was evaluated using monodisperse NaCl particles with Differential Mobility Analyzer and Ultrafine Condensation Particle Counter. Low or medium performance filters show that the most penetrating particles size(MPPS) is around $0.3{\mu}m$ in diameter and is shifted to smaller sizes as the filter face velocity increases. However, HEPA and ULPA filters show MPPS is around $0.15{\mu}m$ in diameter and is also shifted to $0.1{\mu}m$ in diameter as the face velocity increases. In case of electret filter, the MPPS is found around $0.04{\mu}m$ region for Boltzmann charge equilibrium particles. There is a tendency of strong collection efficiency decrease for large particles as the face velocity increases on the contrary to the other filters. One of the medium performance filter efficiency was compared with filtration theory and the good agreetment was found in the experimental range.

  • PDF

Action of serot9ninon the renal function in the dog. (개의 신장기능(腎臟機能)에 대(對)한 Serotonin의 작용(作用))

  • Sub, Byoung-Chul
    • The Korean Journal of Pharmacology
    • /
    • v.2 no.1 s.2
    • /
    • pp.13-16
    • /
    • 1966
  • The action of serotonin (5-Hydroxytryptamine) on the excretory function of the kidney was investigated in the dog, utilizing the clearance method and the stop-flow technique. It was shown that serotonin, $10{\mu}g/kg/min$, i. v., exerts a marked antidiuretic effects and elicits a marked hemodynamic changes in the kidney: a highly significant decrease of the glomerular filtration rate and a tendency of decrement in the renal plasma flow. Little change in the systemic blood pressure was noted, and the participation of the antidiuretic hormone in the antidiuretic action was ruled out by adding vasopressin to the infusion fluid. The stop-flow analysis showed that there is no evidence of altered activity in the tubules by serotonin. It was thus concluded that serotonin elicits anti diuresis in the dog by decreasing glomerular filtration rate, which results from the constriction of Vas afferens in the glomeruli.

  • PDF

A Development Study on High Quality Drinking Water Production by the Biological Activated Carbon/immersed Membrane Filtration System

  • Inoue, Shiro;Iwai, Tosinori;Isse, Masaaki;Terui, Taturo
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2001.07a
    • /
    • pp.155-162
    • /
    • 2001
  • Advanced drinking water production systems, which not only good quality product water, but also provide easy management and mainenance of facilities, and operate on a smaller site area, have been expected to be developed for some time. We are going ahead with a program to deveop an advanced drinking water production system, using immersed membrane filtration combined with biological activated carbon, to meet the need described above. The demonstration plant tests been conducted with surface water from the Yodo-river since Dec. 1998 to measure treatment performance, reliability, and controllability of the system. The quality of product water has consistently remained at a very high level for about 2 years under controlled conditions. Results showed that the re-circulation granular biological activated carbon could suppress the increase of membrane pressure difference and promote a reduction of dissolved organic matter. (This work has been conducted along the ACT21 Programs.)

  • PDF

Permeation Characteristics of Wastewater Containing Si Fine Particles through Ultrafiltration

  • Park, Ho-Sang;Park, Young-Tae;Lee, Seok-Ki
    • Korean Membrane Journal
    • /
    • v.5 no.1
    • /
    • pp.31-35
    • /
    • 2003
  • The permeation characteristics of the wastewater containing Si fine particles were examined by ultrafiltration using the polyolefin tubular membrane module. Flux with time was due to the growth of Si cake deposited on the membrane surface and the pore plugging by fine particles. The rate of flux decline in the initial stage increased with the trans-membrane pressure. The pore blocking resistance was the dominant resistance at the initial period of filtration and the cake resistance began to dominate with the initial pore blocking resistance. The larger pores compared with the fine particles, the more the membrane pores could be blocked by the fine particles. Before and after treatment, the distribution of particle size was shifted toward to the left. Then, the average size of fine particles in the permeate was 20 nm.

Purification and partial characterization of bacillus thuringiensis var.thuringiensis exotoxin (Bacillus thuringiensis var. thuringiensis가 생산하는 .betha.-exotoxin의 정제와 특성)

  • 심창범;이형환;이희무
    • Korean Journal of Microbiology
    • /
    • v.23 no.4
    • /
    • pp.271-281
    • /
    • 1985
  • Bacillus thuringiensis var. thuringiensis produces an extracellular insecticidal thermostable .betha.-exotoxin, which was purified through microfiltering, barium precipitation, charcoal absorption chromatography, ion exchange column chromatography and gel filtration. The exotoxin in each purification step was detedted by thin layer chromatography, high pressure liquid chromatography and paper electrophoresis with efficient results. The exotoxin productivity on time course was checked by spectrophotometric absorbance at 258nm with the result that the exotoxin was initially produced in 6 hour culture and reached maximum value in 36 hour culture. Anti-bacterial effect test on Micrococcus flava was applied as toxicity test. The results showed that frowth inhibition of M. flava could be shown in plate assay of cell free filtered supernatant, alkaline eluant from charcoal and purified exotosin obtained from gel filtration column chromatography on Sephadex G-10 appeared to be 740. Heat stability of the exotoxin was confirmed through autoclaving twice.

  • PDF

Effects of sodium hydroxide cleaning on polyvinylidene fluoride fouled with humic water

  • Jang, Yoon-sung;Kweon, JiHyang;Kang, Min-goo;Park, Jungsu;Jung, Jae Hyun;Ryu, JunHee
    • Membrane and Water Treatment
    • /
    • v.8 no.2
    • /
    • pp.149-160
    • /
    • 2017
  • This study investigated effects of NaOH cleaning on the intrinsic permeability of polyvinylidene fluoride (PVDF) membranes and flux recoveries and membrane resistances under various conditions encountered during ultrafiltration in water treatment plants. The NaOH cleaning using 10,000 mg/L NaOH led to discoloration of PVDF membranes and had little effect on water flux. The NaOH cleaning was efficient in removing the fouling layer caused by humic water. However, long filtration induced a fouling layer that was not removed easily by NaOH cleaning. The lower temperature during filtration yielded rapid increases in transmembrane pressure and decreases in NaOH cleaning efficiency. The alkaline cleaning of PVDF changed the membrane properties such as the hydrophobicity and morphology. Foulant properties, operational conditions such as temperature, and chemical agents should be considered for cleaning strategies for PVDF applied in water treatment.

The Prediction of Injection Distances for the Minimization of the Pressure Drop by Empirical Static Model in a Pulse Air Jet Bag Filter (충격기류식 여과집진기에서 경험모델을 이용한 최소압력손실의 분사거리 예측)

  • Suh, Jeong-Min;Park, Jeong-Ho;Lim, Woo-Taik
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.25-34
    • /
    • 2011
  • The new empirical static model was constructed on the basis of dimension analysis to predict the pressure drop according to the operating conditions. The empirical static model consists of the initial pressure drop term (${\Delta}P_{initial}$) and the dust mass number term($N_{dust}=\frac{{\omega}_0{\nu}_f}{P_{pulse}t}$), and two parameters (dust deposit resistance and exponent of dust mass number) have been estimated from experimental data. The optimum injection distance was identified in the 64 experimental data at the fixed filtration velocity and pulse pressure. The dust deposit resistance ($K_d$), one of the empirical static model parameters got the minimum value at d=0.11m, at which the total pressure drop was minimized. The exponent of dust mass number was interpreted as the elasticity of pressure drop to the dust mass number. The elasticity of the unimodal behavior had also a maximum value at d=0.11m, at which the pressure drop increased most rapidly with the dust mass number. Additionally, the correlation coefficient for the new empirical static model was 0.914.

Performance Evaluation of Ball Media Filter in DABF applied to SWRO pretreatment process (SWRO 전처리 공정에 적용된 DABF 내 Ball Media Filter 성능 평가)

  • Choi, Seokho;Lee, Junghyun;Park, Sungju;Lee, Younggeun;Roh, Hyungkeun;Kim, Yongbeom
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.6
    • /
    • pp.567-573
    • /
    • 2019
  • DABF(Dissolve Air Flotation with Ball Filter) is developed as the DAF with the addition of a fiber ball at the lower part of the DAF. The DABF with a capacity of 4,500 ㎥/h was constructed at Gijang SWRO plant in Busan. Since the ball filter has high filtration rate, the loading rate of DABF was designed from 20 to 42 ㎥/h/㎡. When one DABF basin is in the back washing mode, the loading rate of other two DABF basins is increased to 42 ㎥/h/㎡. Turbidity at the BF outlet in DABF is <2 NTU at turbidity of 5-10 NTU at the BF inlet. If there is no algae bloom and turbidity is low in raw seawater, only BF in DABF is operated and meets <2 NTU at the BF outlet. Even if BF is operated at high hydraulic loading rates, no significant differential pressure increases and reduction in the turbidity removal rate is minimal in a day. Thus, DABF is the pre-treatment technology that provides stable water quality even with BF onlyoperation without DAF operation. Compared with the DAF, DABF requires additional facilities such as valves, piping, and drainage systems for backwashing the BF. But in terms of footprint and operating costs, DABF has more advantages than DAF. With DABF application, the load of the downstream filtration equipment is decreased so that the capacity of the filtration equipment can be reduced. Also, if the downstream filtration equipment is to be maintained the same regardless of DABF, the operating cost of DABF is less than DAF.

A Study of High Temperature Filtration Performance Test on Low Density Cylindrical Ceramic Filters (저밀도 원통형 세라믹 필터의 고온 여과 성능시험 연구)

  • 이동섭;홍민선;최종인
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.213-222
    • /
    • 2001
  • Cylindrical type ceramic filers, that is 60 O.D$\times$10t$\times$600L and 60 O.D$\times$10t$\times$1,000L were manufactured by vacuum forming processes using ceramic ray materials. For cylindrical type ceramic filters, porosity and bulk density were measured for, 80 to 90% and 0.3 to 0.4 g/㎤, respectively at uniform pore size of 41 to 45${\mu}{\textrm}{m}$. Bench scale candle filters (60$\psi$ $\times$10t$\times$600L) were tested using different dusts collected from many industries including chemical processing, glass processing and metal manufacturing pants. Collection efficiencies found out to range from 99.87% to 99.90%, while resistance coefficients from 1.1$\times$10(sup)11/$m^2$ to 1.7$\times$10(sup)11/$m^2$ . Full scale low density ceramic filters (60$\psi$ $\times$10t$\times$1,000L) were also tested at 1 atm, $600^{\circ}C$ to reveal the filtration efficiency, conditioning, and resistance coefficients using two different types of dust as chemical processing and metal refined processing. Darcys law resistance coefficients were measured to range 1.44$\times$10(sup)11/$m^2$ to 2.74$\times$10(sup)11/$m^2$, and collection efficiencies on the range 99.84 to 99.96%, Finally, results of long term performance test showed that filters were conditioned after 170hrs. Experimental conditions for effective filtration were examined under the condition 10 cm/sec face velocity, 3kg/$\textrm{cm}^2$ pulsing pressure, 5 min filtration cycle, and 300msec pulse opening time.

  • PDF

The Effect of Media on the Removal Efficiency and Filtration Performance in the Submerged Membrane-Coupled Sequencing Batch Reactor with Media (담체가 첨가된 침지형 막결합 연속회분식 반응기에서 제거효율과 여과성능에 대한 담체의 효과)

  • Kim, Seung-Geon;Lee, Ho-Won
    • Membrane Journal
    • /
    • v.22 no.6
    • /
    • pp.450-460
    • /
    • 2012
  • In the submerged membrane-coupled sequencing batch reactor (MSBR) with sponge type media, the effect of media on the removal efficiency and filtration performance were investigated. Dosages of the media in the MSBR were set of 5%, 10%, and 20% based on working volume of reactor. As a control system, the MSBR without media was also operated. The experimental results showed that there was also no difference observed in the removal efficiencies of COD, T-N, and T-P irrespective of the dosages of the media. But TMP (transmembrane pressure) of the MSBR with media increased slowly during the operation time, while that of the MSBR without media increased rapidly at the initial operation. This result was thought that the collisions between flat membrane and moving media gave shear forces which decreased the cake layer on the surface of flat type membrane. Consequently, this study showed that filtration performance of the MSBR with media was greatly enhanced compared with that of the MSBR without media. The MSBR with media suggested in this study can be a good candidate for the wastewater treatment.