• Title/Summary/Keyword: Pressure endurance test

Search Result 62, Processing Time 0.029 seconds

A Study on the Air Pressure Endurance Test Device for High Speed Train Windows (고속철도차량 객차창문의 공기압력내구성 시험장치 개발에 관한 연구)

  • Chang, Dae-Sung;Yi, Won
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.2
    • /
    • pp.104-108
    • /
    • 2012
  • All of the Korean high speed train windows have been imported from abroad up to now. In this paper, the air pressure endurance test device for high speed train windows was studied and developed. This test device can create air pressure variation similar to train running real condition and carry out pressure endurance test according to international standard. Henceforward, this test device will be useful for domestic production of high speed train windows.

Development of In-tank Pressure Regulator and Solenoid Valve (내장형 레귤레이터 및 솔레노이드 개발)

  • Lee, Jun-Hyuk;Lim, Tae-Hoo;Kim, Kyung-Nam;Shim, Sang-Hak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.188-191
    • /
    • 2007
  • This paper shows the Development of In-tank pressure regulator and Solenoid Valve used in FCV(Fuel Cell Vehicle). We have developed new type of Regulator and Solenoid through analysis of the structure and characteristics of component of FCS(Fuel Cell System) from the advanced technology. Now it is possible to localize the component by making use of the development of Regulator and Solenoid made by us. Regulator and Solenoid is a equipment to control hydrogen pressure supplied into a stack. Therefore, outlet pressure, a flow of fluid and temperature are important parameters according to a inlet pressure. And leak test, endurance test and burst test should be done to guarantee the performance and safety of Regulator and Solenoid used in the fuel of high pressure. Also, Hydrogen friendly materials are applied to inner parts of the Regulator, Solenoid and weight reduction is done to cost saving in part not related to performance. As a result, we have proven the good performance and reliability in endurance of Regulator, Solenoid and will make an development in performance as well as durability to ensure industrialization.

  • PDF

A study on the Pressure Test of the Glass Window for High Speed Train (고속철도차량용 창문유리의 압력시험에 관한 연구)

  • Chang, Dae-Sung;Yi, Won
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.5
    • /
    • pp.391-397
    • /
    • 2011
  • In this paper, the pressure endurance test of passenger train's glass window which was developed for next high speed train was studied. At first, pressure test equipment which will be able to generate the maximum pressure same as crossing case between two trainsets in the tunnel was developed. Afterwards the pressure test and evaluation that are based on NFF31-314 were carried out and studied.

Compatibility test of a non-instrumented irradiation test capsule for the HANARO test reactor (환형소결체 하나로 조사시험용 무계장 캡슐의 연구로 설치 적합성시험)

  • Lee, Kang-Hee;Kim, Dae-Ho;Chun, Tae-Hyun;Kim, Hyung-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.226-229
    • /
    • 2008
  • To investigate an in-pile behavior of the newly developed DUO fuel pellet, the irradiation test will be carried out in the domestic test reactor. Irradiation test capsule for the HANARO reactor, which is a specially designed equipment used for material, irradiation and creep test, must satisfy the operational requirement on the hydraulic characteristics and structural integrity. In this study, a pressure drop, a flow-induced vibration and a short-term endurance test for the newly developed non-instrumented test capsule were carried out using FIVPET as a out-pile evaluation test. The test results show that the new test rig satisfy the HANARO operational requirement with sufficient margin.

  • PDF

Endurance of Pneumatic Valve with a Multi-bender PZT Actuator (적층 벤더형 압전식 공압밸브의 내구 특성)

  • Yun, So-Nam;Park, In-Sub
    • Journal of Power System Engineering
    • /
    • v.18 no.2
    • /
    • pp.31-36
    • /
    • 2014
  • In this paper, pneumatic valve which consists of valve body, valve controller, nozzle and a multi-bender PZT actuator was suggested and fabricated. The fabricated pneumatic valve was experimented for performance evaluation. From the experimental results, we know that the flow rate of the suggested valve is 23 lpm at the pressure difference of 1bar and the maximum flow rate is 30 lpm at the pressure difference of 4 bar. The flow rates after endurance test of 9.8 million were 22.57 lpm and 28.62 lpm at the pressure difference of 1bar and 4bar, respectably. Finally, it was verified that the B10 life of the suggested pneumatic valve is over 50 million.

A study on the pressure test of the glass window for high speed train (고속철도차량용 창문유리의 압력시험에 관한 연구)

  • Chang, Dae-Sung;Lee, Heung-Jae;Yi, Won
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.295-300
    • /
    • 2011
  • In this paper, the pressure endurance test of passenger glass window which was developed for next high speed train was studied. At first, pressure test equipment which will be able to generate the maximum pressure same as crossing between two trainsets in the tunnel was developed. Afterwards the pressure test and evaluation that were based on NFF31-314 were studied and carried out.

  • PDF

Properties of Fire Endurance of High Performance RC Column with Laterral Confinement Method (횡구속 방법에 따른 고성능 RC 기둥 콘크리트의 내화특성)

  • Hwang Yin Seong;Kim Ki-Hoon;Bae Yeoun Ki;Lee Bo Hyeong;Lee Jae Sam;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.553-556
    • /
    • 2004
  • This paper is to investigate the spalling and fire endurance of high performance RC column member with PP fiber and lateral confinement of metal lath and non fire resistance removal type form. According to test results, combination of PP fiber and metal lath as well as use fire resistance non removal type form had favorable fire resistance by discharging internal vapour pressure and lateral confining. After fire endurance test, compressive strength decreased markedly caused by internal expansion pressure and crack. Residual strength of plain concrete was decreased to $22\%$. The use of PP fiber and lateral confinement of metal lath and non removal type form enhanced the residual strength above $40\%$. Especially, the combination of $0.1\%$ of PP fiber and lateral confinement with the level of 2.3T exhibited more than $51\%$ of residual strength. Therefore, to improve fire endurance and spalling resistance, the combination of $0.1\%$ of PP fiber and metal lath with 2.3T can be the proper measure.

  • PDF

Inter Propellant Seal Performance test for 75 ton Class Turbopump (75톤급 터보펌프 추진제 혼합 방지 실의 성능 시험)

  • Jeon, Seong-Min;Kwak, Hyun-Duck;Park, Min-Joo;Kim, Jin-Han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.5
    • /
    • pp.57-64
    • /
    • 2010
  • A performance test of inter propellant seal for a 75 ton class turbopump is conducted using water to evaluate leakage and endurance performance. Each part of fuel pump side and oxidizer pump side for a prototype inter propellant seal has been tested for verifying endurance performance during total accumulated test time 2,100 sec in water. The fuel pump side part with one-stage seal of carbon floating ring shows average leakage rate 13.7 gram/sec under average seal differential pressure 9.4 bar. On the other hand, the oxidizer pump side part with two-stage seal assembly of carbon floating rings shows average leakage rate 7.3 gram/sec under average seal differential pressure 9.5 bar. After the endurance performance test, the inter propellant seal shows good physical condition. A leakage performance test of the inter propellant seal for cryogenic environment will be performed using LN2 in the near future.

Inter Propellant Seal Performance test for 75 ton Class Turbopump (75톤급 터보펌프 추진제 혼합 방지 실의 성능 시험)

  • Jeon, Seong-Min;Kwak, Hyun-Duck;Park, Min-Joo;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.47-53
    • /
    • 2010
  • A performance test of a 75 ton class turbopump inter propellant seal is conducted using water to evaluate leakage and endurance performance. Each fuel pump side part and oxidizer pump side part of a prototype inter propellant seal has been tested for verifying endurance performance during total accumulated test time 2,100 sec in water. The fuel pump side part with 1 stage carbon floating ring seal shows average leakage rate 13.7 gram/sec under average seal differential pressure 9.4 bar. On the other hand, the LOx pump side part with 2 stage carbon floating ring seal shows average leakage rate 7.3 gram/sec under average seal differential pressure 9.5 bar. After the endurance performance test, the inter propellant seal shows good physical condition. A cryogenic leakage performance test of the inter propellant seal will be performed using LN2 in the near future.

  • PDF