Experimental Evaluation of Internal Blast Resistance of Prestressed Concrete Tubular Structure according to Explosive Charge Weight (프리스트레스트 콘크리트 관형 구조물의 폭발량에 따른 내부폭발저항성능에 관한 실험적 평가)

  • Choi, Ji Hun;Choi, Seung Jai;Yang, Dal Hun;Kim, Jang-Ho Jay
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.3
    • /
    • pp.369-380
    • /
    • 2019
  • When a extreme loading such as blast is applied to prestressed concrete (PSC) structures and infrastructures for an instantaneous time, serious property damages and human casualties occur. However, a existing design procedure for PSC structures such as prestressed containment vessel (PCCV) and gas storage tank do not consider a protective design for extreme internal blast scenario. Particularly, an internal blast is much more dangerous than that of external blast. Therefore, verification of the internal blast loading is required. In this paper, the internal blast resistance capacity of PSC member is evaluated by performing internal blast tests on RC and bi-directional PSC scaled down specimens. The applied internal blast loads were 22.68, 27.22, and 31.75 kg (50, 60, and 70 lbs) ANFO explosive charge at 1,000 mm standoff distance. The data acquisitions include blast pressure, deflection, strain, crack patterns, and prestressing force. The test results showed that it is possible to predict the damage area to the structure when internal blast loading occurs in PCCV structures.

Stress and Fatigue Evaluation of Distributor for Heat Recovery Steam Generator in Combined Cycle Power Plant (복합발전플랜트 배열회수보일러 분배기의 응력 및 피로 평가)

  • Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.44-54
    • /
    • 2018
  • Stress and fatigue of the distributor, an equipment of the high-pressure evaporator for the HRSG, were evaluated according to ASME Boiler & Pressure Vessel Code Section VIII Division 2. First, from the results of the piping system analysis model, reaction forces of the tubes connected to the distributor were derived and used as the nozzle load applied to the detailed analysis model of the distributor afterward. Next, the detailed model to analyze the distributor was constructed, the distributor being statically analyzed for the design condition with the steam pressure and the nozzle load. As a result, the maximum stress occurred at the bore of the horizontal nozzle, and the primary membrane stress at the shell and nozzle was found to be less than the allowable. Next, for the transient operating conditions given for the distributor, thermal analysis was performed and the structural analysis was carried out with the steam pressure, nozzle load, and thermal load. Under the transient conditions, the maximum stress occurred at the vertical downcomer nozzle, and of which fatigue life was evaluated. As a result, the cumulative usage factor was less than the allowable and hence the distributor was found to be safe from fatigue failure.

Space Business and Applications of Vacuum Technology (우주개발과 진공기술의 응용)

  • Lee, Sang-Hoon;Seo, Hee-Jun;Yoo, Seong-Yeon
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.270-277
    • /
    • 2008
  • Vacuum is any air or gas pressure less than a prevailing pressure in an environmental or, specifically, any pressure lower than the atmospheric pressure and is used by a wide variety of scientists and engineering - including clean environment, thermal insulation, very long mean free path, plasma, space simulation[1]. The space environment is characterized by such a severe condition as high vacuum, and very low and high temperature. Since a satellite will be exposed to such a space environment as soon as it goes into its orbit, space environmental test should be carried out to verify the performance of the satellite on the ground under the space environmental conditions. A general and widely used method to simulate the space environment is using a thermal vacuum chamber which consists of vacuum vessel and thermally controlled shroud. As indicated by name of vacuum chamber, the vacuum technology is applied to design and manufacture of the thermal vacuum chamber. This paper describe the vacuum technology which is applied to space business.

Effects of Exercise Designed on Physiological Variables Physical Functions in the Elderly (맨손체조가 노인의 생리적 지수와 체력에 미치는 효과)

  • Min, Soon;Joo, Ae-Ran
    • Journal of Korean Biological Nursing Science
    • /
    • v.4 no.1
    • /
    • pp.71-83
    • /
    • 2002
  • The purpose of this study was to determine the effect of exercise designed on physiological variables, physical functions in the elderly. The research design used was the one group pre-post test quasi-experimental design. The subjects for this study were 23 elderly, who were conveniently assigned to experimental group. The experimental group were selected from G-elderly church club in G-city. The data were collected from March 5, 2001 to June 11, 2002, and analyzed by frequency, t-test using SPSS/PC program. The results of this study were summarized as follows ; 1) The heart rate in the experimental group show statistically significant improvement (t=2.316, p=0.030). 2) The systolic blood pressure & diastolic blood pressure in the experimental group show statistically significant improvement(t=2.277, p=0.033 & t=-2.989, p=0.007). 3) The peripheral vessel $O_2$ Saturation in the experimental group don't show statistically significant improvement(t=-1.096, p=0.285). 4) The physical function in the experimental group don't show statistically significant improvement(t=-0.746, p=0.464). After 15 weeks of exercise designed, it was shown that the program was effective to improve the physiological variables.

  • PDF

Design and Fabrication of Digital 3-axis Magnetometer for Magnetic Signal from Warship (함정 자기신호 측정용 3-축 디지털 자기센서 설계 및 제작에 관한 연구)

  • Kim, Eunae;Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.4
    • /
    • pp.123-127
    • /
    • 2014
  • We developed a digital 3-axis flux-gate magnetometer for magnetic field signal measurement from warship during demagnetizing and degaussing processes. For the magnetometer design, we considered following points; the distance between magnetic field measurement station and magnetometer located under sea is about several 100 m, the magnetometer is exposed to magnetic field of ${\pm}1mT$ during demagnetizing process, and magnetometer is located under the sea about 30 m depth. To overcome long distance problem, magnetometer could be operated on wide input supply voltage range of 16~36 V using DC/DC converter, and for the data communication between the magnetometer and measurement station a RS422 serial interface was employed. To improve perming effect due to the ${\pm}1mT$ during demagnetizing process, magnetometer could be compensated external magnetic field up to ${\pm}1mT$ but magnetic field measuring rang is only ${\pm}100{\mu}T$. The perming effect was about ${\pm}2nT$ under ${\pm}1mT$ external magnetic field. The magnetometer was tested water vessel with air pressure up to 6 bar for the sea water pressure problems. Linearity of the magnetometer was better than 0.01 % in the measuring range of ${\pm}0.1mT$ and noise level was $30pT/\sqrt{Hz}$ at 1 Hz.

A Study on the Configuration of Two-Dimensional Waterjet Inlet (이차원 물분사 추진장치 입구면 형상에 관한 연구)

  • J.M. Lew;S.K. Hong;Y.G. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.2
    • /
    • pp.9-21
    • /
    • 1999
  • The waterjet is very widely used today in propulsion system of high speed vessel but manufacturer is limited because of an efficiency and a difficulty of a manufacture on the inlet configuration of the waterjet. The importancy in designing the inlet configuration of the waterjet lies on the minimization of the cavitation which is largely affecting the efficiency. In this paper, the configuration analysis is carried out to find a optimum shape which is minimizing the cavitation using a two dimensional potential-based panel method with an inlet configuration of a flush type. Also, it is developed a direct design method finding an inlet configuration by a given pressure distributions. The numerically obtained optimum shape using this configuration analysis method show a good agreement compared to the Kashiwadani's results. It is carried out a direct design method over a lip and a ramp of an inlet configuration wish pressure distributions obtained a result of the configuration analysis and the results show a good agreement compared to original configuration.

  • PDF

A Study on Thermal Performance of Plate Cooler for Cooling Medium Speed Engine Lubricant Oil (선박용 중속엔진 오일냉각용 판형쿨러의 전열성능에 관한 연구)

  • Park, Jae-Hong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.83-90
    • /
    • 2020
  • Plate heat exchangers(PHE) have been commercialized since the 1920s. Since then, although the basic concept of PHEs has changed little, its design and construction have progressed significantly to accommodate higher temperatures, higher pressures, and large heat exchanging capacities. The development trend of PHEs is consistent with heat plate developments with better thermal efficiency, lower pressure drop, and good flow distribution. The purpose of this paper is to introduce the main development processes of a plate cooler for medium-speed engine lubricant oil cooling in vessels which is in line with the development trend of PHEs and to provide its thermal performance data that were found out during experimental tests. The plate cooler in this study cannot measure the wall temperatures directly due to its structural characteristics, so the heat transfer coefficients were calculated using the modified Wilson Plot method. The water-to-water tests were first conducted experimentally to figure out the characteristics of heat transfer coefficients and pressure drops on the water side and then the water-to-oil tests followed to obtain the heat transfer coefficients on the oil side. The test results showed that heat transfer coefficients and pressure drops on both water and oil side increased with flow rates, and it was also found that all the development targets of the plate cooler in this study were achieved successfully.

Design of I-123 Nuclide production system (I-123 핵종생산장치 시스템 설계)

  • Jung, Hyun-Woo;You, Jae-Jun;Kim, Byung Il;Chun, KwonSoo;Lee, Ji-Seub;Park, Hyun;Choi, JunYong;Oh, Se-Young;Bang, Sang-Kwon;Lee, Dong Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.496-499
    • /
    • 2014
  • Xe Gas is moved to Target from GPM. It is Used to feasible nuclear reaction from proton of 30MeV Cyclotron being investigated by the Xe-124 Gas target System. This system is divided into four parts. Hardware was constructed by solidworks and Helium Supply is to cool the Havor Foil. Water has the job of cooling down the temperature when Xe Gas is being investigated in the target. Temperature and pressure gauges are attached to be checked easily. GPM(Gas Process Manifold) has the part that prepares to transport Xe Gas. There are Storage Vessel that stores Xe Gas, the cold trap that filters humidity and impurity and lastly storage vessel that temporarily stores Xe Gas. HCS(Helium Circulation System) using the Helium to cleaning and cooling. these parts are used to SIEMENS PLC and Pcvue Program. Because It is more comfortable and easy maintenance.

  • PDF

Effects of Dance Sports on Physiological Variables, Depression and Quality of Life in the Elderly (댄스스포츠가 노인의 생리적 지수, 우울, 삶의 질에 미치는 효과)

  • Joo, Ae-Ran;Park, In-Hyae
    • Journal of Korean Biological Nursing Science
    • /
    • v.3 no.2
    • /
    • pp.69-90
    • /
    • 2001
  • The purpose of this study was to determine the effect of dance sports on physiological variables, depression and quality of life in the elderly. The study was performed on a non-equivalent control group pretest-posttest design for 47 elderly, who were conveniently assigned to experimental group and control group. The experimental group were selected from D-welfare facility and the control group were selected from G-elderly church club in G-city. The data were collected from April 2, 2001 to June 30, 2001, and analyzed by frequency, $x^2$-test, t-test and paired t-test using SAS/PC program. The results of this study were summarized as follows; 1. The first hypothesis, "the experimental group would have improved physiological variables than the control group.". 1-1. The hypothesis, "the experimental group would have lower blood pressure than the control group" was rejected. 1-2. The hypothesis, "the experimental group would have lower heart rate than the control group" was supported(t=-2.031, p=0.048). 1-3. The hypothesis, "the experimental group would have higher peripheral vessel $O_2$ Saturation than the control group" was rejected. 2. The second hypothesis, "the experimental group would have lower depression score than the control group" was supported(t=2.832, p=0.006). 3. The third hypothesis, "the experimental group would have higher quality of life score than the control group" was supported(t=2.604, p=0.012). After 12 weeks of dance sports program, it was shown that the program was effective to improve the physiological varibles, reduce depression and improve quality of life.

  • PDF

Analysis of Burnable Poison Effect on Power Distribution using Power Sensitivity Coefficient Concept (출력민감도 계수개념을 이용한 가연성 독붕봉이 출력분포에 미치는 영 향의 분석)

  • Yi, Yu-Han;Oh, Soo-Youl;Seong, Seung-Hwan;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.19-26
    • /
    • 1988
  • The low leakage leading pattern has features as the placement of some fresh fuel assemblies in the core interior to reduce the neutron fluence on the pressure vessel and to enhance the neutron economics. But as fresh fuel assemblies are loaded in the core interior, the local power tends to exceed safety limit due to the high reactivity of the fresh assemblies. Therefore, a large number of burnable poisons must be utilized in a low leakage scheme to suppress the high assembly power as well as the excess reactivity. In this study the effects of burnable poisons are treated as a perturbation on the power distribution, and the 'Power Sensitivity Coefficient' concept is adopted. An application study is performed for cycle 1 of the Korea Nuclear Unit-7 (KNU-7) to justify the usefulness of the reverse depletion method coupled with the above concept. To obtain the optimal burnable poision distribution at the given burnup step, the linear programming technique is adopted. The result shows maximum 4.5% error in the amount of burnable poisons between the calculated and the reference values. It is concluded that the design methodology which consists of the reverse depletion, the power sensitivity coefficient concept, and the linear programming technique can be used to find the optimal turnable poison distribution.

  • PDF