• Title/Summary/Keyword: Pressure Test

Search Result 7,892, Processing Time 0.029 seconds

Evaporation Pressure Drop of Carbon Dioxide in a Horizontal Tube (수평관내 이산화탄소의 증발 압력강하)

  • Ku, H.K.;Son, C.H.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.63-69
    • /
    • 2007
  • The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and an evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of 4.57 mm inner diameter. The experiments were conducted at saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed that the evaporation pressure drop of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The measured pressure drop during the evaporation process of $CO_2$ increases with increased mass flux, and decreased saturation temperature. The evaporation pressure drop of $CO_2$ is much lower than that of R 22. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the previous correlation. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

  • PDF

A Method of ROL Improvement for the Motor Operated Gate Valve Operated in the High Differential Pressure Condition (고차압에서 운전되는 모터구동 게이트밸브의 부하율 향상 방안)

  • Kim, D.W.;Yoo, S.Y.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.1 s.28
    • /
    • pp.16-22
    • /
    • 2005
  • This paper presents the method of ROL(Rate Of Loading) improvement for the Motor Operated Gate Valve operated in high differential pressure condition. ROL is one of the most important evaluation parameters for the valve ability. It is close to correlation in stem factor (SF) and appears different value by the differential pressure of fluid. ROL and SF are analyzed by the static test and dynamic test. The obtained result show that the modification of stem factor is very important factor for the ROL improvement. In order to obtain the same value of SF between static and dynamic test, stem and stem nut should be combined appropriately by the repetition test.

A Study on the Proper Pore pressure ratio in Continuous Loading Consolidation tests (연속재하 압밀시험에서 적정 간극수압비에 관한 연구)

  • Chae, Sum-Sik;Lee, Song
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.271-276
    • /
    • 2002
  • Continuous loading is applied the sample has been developed to overcome some of the problems associated with the incremental loading consolidation test. Therefore, it is able to reduce the test time and provide a well defined the curve of effective stress versus strain due to continuous stress-strain points. Also, the constant rate of strain consolidation(CRSC) test has been accepted widely as a standard method in foreign countries because of its many advantages. However, in Korea the CRSC test has not been used in engineering practice and experimentally verified. Because there is not a precise criterion of testing despite consolidation characteristics are influenced on strain rate and Pore pressure ratio. Consequently, it is difficult to apply in engineering practice. In this study, artificial neural networks are applied to the estimation of th proper strain rate and pore pressure ratio of the CRSC test. This study shows the possibility of utilizing the artificial neural networks model of estimation of the strain rate and pore pressure ratio in the CRSC test.

  • PDF

Manufacturing and Performance Test of Obsolete Valve in NPP using DED Metal 3D Printing Technology (원전 단종 밸브의 DED 방식 금속 3D프린팅 제작 및 성능시험)

  • Kyungnam Jang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.2
    • /
    • pp.75-82
    • /
    • 2021
  • The 3D printing technology is one of the fourth industrial revolution technology that drives innovation in the manufacturing process, and should be applied to nuclear industry for various purposes according to the manufacturing trend change. In nuclear industry, it can be applied to manufacture obsolete items and new designed parts in advanced reactors or small modular reactors (SMRs), replacing the traditional manufacturing technologies. A gate valve body was manufactured, which was obsolete in nuclear power plant, using DED(Directed Energy Deposition) metal 3D printing technology after restoring design characteristics including 3D design drawing by reverse engineering. The 3D printed valve body was assembled with commercial parts such as seat-ring, disk, stem, and actuator for performance test. For the valve assembly, including 3D printed valve body, several tests were performed, including pressure test, end-loading test, and seismic test according to KEPIC MGG and KEPIC MFC. In the pressure test, hydraulic pressure of 391kgf/cm2 was applied to 3D printed valve body, and no leak was detected. Also the 3D printed valve assembly was performed well in end-loading and seismic tests.

A Study on the Mechanical Method of Observing Winding Behavior by Charging and Discharging of Type II High Pressure Hydrogen Storage Tank (Type II 고압수소저장용기의 충전과 방출에 의한 권선 거동 관찰의 기계적 방법에 관한 연구)

  • KIM, SEUNGHWAN;HAN, JINMOOK;LEE, SUNGHEE;JUNG, YOUNGGUAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.2
    • /
    • pp.158-163
    • /
    • 2022
  • The test method on the Type II high-pressure hydrogen storage tanks made of the metal wire hoop winding is a complex and high risk. Also closeup on the tank being test is difficult. In this study, we studied a mechanical test method for a high-pressure hydrogen tanks. This method must be simple, risk-free and possible to observe the change in microscopic behavior of a metal wire on a liner. As the results, it was possible to observe the microscopic behavior on the metal wire by the mechanical test method. Also, a simple and risk-free test was possible compared to the conventional test method for high pressure hydrogen tanks.

Earth Pressures Acting on the Rigid Wall under Incremental Load (점증하중에 의한 강성벽체에 작용하는 토압)

  • Chon, Yong-Baek;Kwon, Uk-Hwa
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.3
    • /
    • pp.247-254
    • /
    • 2002
  • This study has researched the following conclusion to compare to the existing theory and to examine lateral earth pressure, which have measured to add incremental load on sandy soil, and were different in types of compaction by modeling earth pressure test. Lateral earth pressure by incremental load shows that it is increasing at depth forty four centimeters as 2/3H point for wall high, and under 2/3 H point the variation of earth pressure on incremental load is not conspicuous. Therefor, the more a position of surcharge load is close with fixed wall, the more a variation of lateral earth pressure marks considerably. According to relative compaction density of soil, lateral earth pressure turns up larger effective value for layer compaction test to a thickness of thirty three centimeters than layer compaction test to a thickness of twenty centimeters by the roller.

  • PDF

Collapsible Phenomena in the Flexible Tubes due to the Flow Rate and Transmural Pressure Changes (유량과 벽면횡단압력의 변화에 의한 유연한 관의 압착현상)

  • Cho, Min-Tae;Suh, Sang-Ho;Yoo, Sang-Sin
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.377-380
    • /
    • 2000
  • The collapsible phenomena of the circular tubes due to the excessive transmural pressure are investigated experimentally. Collapsible tubes are installed in the test section where the external pressure is applied to the test tubes by applying the hydrostatic head. The collapsible circular tubes are made of rubber, whose diameters are 6 and 4.2 mm, respectively. The hydrostatic water head of the upper reservoir is applied to the test section. Pressures at the upstream and downstream sides are measured by the pressure transducers. The collapsible phenomena are observed as the transmural pressure Increases, and also the flutter phenomenon occurs due to the critical transmural pressure.

  • PDF

The Evaluation of 16x16 JDFA Pressure Loss Coefficients Using the Fuel Assembly Compatibility Test System

  • Lim, Hyun-Tae;Jun, Byung-Soon;Kim, Hong-Ju;Jeon, Kyeong-Lak
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.254-259
    • /
    • 1996
  • The hydraulic tests for 16$\times$16 JDFA were performed to obtain the pressure loss coefficients using the FACTS. The pressure loss coefficients are calculated by converting the each properties of experimental values for inlet region, mixing vane grid, outlet region and core region by performing a power fit of the pressure loss coefficient values to the corresponding Reynolds number. The test results are compared with the existing calculated values and evaluated by using the CALOPR code in terms of pressure drop. It is turned out that the differences between the test results and the calculated values are about by 3.8% for the pressure loss coefficients and by 8.5% for the pressure drop.

  • PDF

Numerical Analysis of Pressure Propagation to the Main Charge by Warhead Penetration into Concrete Targets (탄두의 콘크리트 표적관통 시 주장약에 전파되는 압력의 수치해석)

  • Yun, Kyung Jae;Yoo, Yo-Han
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.339-345
    • /
    • 2016
  • This paper is concerned with the numerical simulation result of pressure propagation to the main charge by warhead penetration into concrete targets. In this study, we developed on-line pressure measurement method in the main charge during warhead penetration. Using the on-line pressure measurement method, we successfully recorded the pressure-time history in the main charge during the field penetration test. Then we compared result of numerical simulations with test data and found that the simulation results are in good agreement with the test results. Finally, through the numerical calculations it is concluded that the installation of liner is effective in reducing pressure level produced in the main charge.

The Fusion Characteristic Varying with Butt Fusion Times for Polyethylene Pipe (PE배관 버트 융착 시간에 따른 융착 특성 변화)

  • 이영순;장영오
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.199-205
    • /
    • 1998
  • Butt fusions were practiced with butt fusion in the various conditions of fusion temperatures, pressure and time, and the tests of tesile strength, breaking water pressure and fusion features were also practiced so that the reliability of the butt fusion and the fittets fusion condition may be closely examined. And the width, height and thickness of the beads were also closely measured. The fittest fusion result was achieved in the condition of the temperature of $210^{\circ}C$, heating time hight pressure of 14 seconds on the pressure of $1.5kg/cm^2$, heating time hight pressure of 100 seconds and pressure buid-up time of 11 seconds. And in case of the temperature of $250^{\circ}C$, the fittest fusion result was showed in the condition of the heating time hight pressure of 3 seconds on the pressure of 1.0$kg/cm^2$, the heating time low pressure variable of 100 seconds. heating time hight pressure of 14 seconds and the heating maintenance of around 60 seconds. The result of breaking water pressure test of a test piece fusion in the fittest fusion condition was that the fusion condition of the PE pipe showed a good stability and hight reliance. Through this test, it is proved that the temperature of fusion PE pipes can be increased to $250^{\circ}C$ from $210^{\circ}C$. And it can be expected that the above fusion method greatly helps to reduce the fusion time.

  • PDF