• 제목/요약/키워드: Pressure Monitoring

검색결과 1,101건 처리시간 0.025초

가스계 소화시스템용 소화약제 저장용기 누설 검출 무선 시스템 개발 (Development of Monitoring RF System on Leakage of Gas Cylinder in Gaseous Fire Extinguishing System)

  • 소수현;오주환;차철웅;이대근
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.7-10
    • /
    • 2008
  • In our study, Monitoring RF System in real-time on leakage of gas cylinder is developed. The system is consisted of Pressure Transmitting part, Main Controller and Operating program. The pressure data of gas cylinder are transmitted to the modem of main controller part by RF module of Pressure Transmitting part and the data received through the modem are recorded in real-time and showed the situation of gas cylinder on the PC monitor. Through the test on the case of the artificial pressure-reduction, the detecting performance. of the developed system is conformed.

  • PDF

대도시 급배수관망의 수압변화 특성에 관한 연구 (A Study on Hydraulic Pressure Change Characteristics of Water Distribution Networks in Large Cities)

  • 오창주;김태경;이경훈
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.279-287
    • /
    • 2005
  • In this study, I suggest an effective operation of waterwork facilities in large cities and a scientific method for utilizing water in water distribution systems. To achieve this goal, my simulation were carried out on data from Kwangju City using Pipenet '98, a pipe-network program. From this simulation, I examine the possibilities of application the system in large cities, comparing data measured at 33 hydraulic pressure monitoring places from waterwork enterprises. The result is coincident with that of waterwork enterprises, with about a 12.5% average error rate and $0.32kg/cm^2$ average deviation. The method and program I use here can be helpful in cities where there is a need to extend the waterwork facilities, or where there is a need to suspend the water supply, and/or there is an accident. The simulation shows how to expand waterwork facilities effectively, how to prevent accidents, and how to estimate the hydraulic pressure even in the areas without monitoring places.

LC 공진형 압력 센서를 이용한 돼지 경골 동맥의 실시간 혈압 측정 (Real-time Blood Pressure Monitoring in Porcine Tibial Artery Using LC Resonant Pressure Sensor)

  • 최원석;김진태;정연호
    • 한국전기전자재료학회논문지
    • /
    • 제25권6호
    • /
    • pp.445-450
    • /
    • 2012
  • We have developed an implantable wireless sensor for real time pressure monitoring of blood circulation system. MEMS (micro-electro-mechanical system) technology was adopted as a sensor development method. The sensor is composed of photolithographically patterned inductors and a distributed capacitor in gap between the inductors. A resulting LC resonant system produces its resonant frequency in range of 269 to 284 MHz at 740 mmHg. To read the resonant frequency changed by blood pressure variation, we developed a custom readout system based on a network analyzer functionality. The bench-top testing of the pressure sensors showed good mechanical and electrical functionality. A sensor was implanted into tibial artery of farm pig, and interrogated wirelessly with accurate readings of blood pressure. After 45 days, the sensor's electrical response and histopathology were studied with good frequency reading and biocompatibility.

선박엔진성능분석용 웹기반 장기모니터링시스템 구현 (Long-term Monitoring System for Ship's Engine Performance Analysis Based on the Web)

  • 권혁주;양현숙;김민권;이성근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.483-488
    • /
    • 2015
  • 본 논문에서는 엔진유지관리 개선을 위해 Web 기반 선박엔진성능분석용 장기모니터링시스템을 구현하고자 한다. 이 시스템은 시뮬레이터, 다채널 A/D 변환기가 내장된 감시모듈, 모니터링 컴퓨터, 네트워크저장기(NAS), RS485 및 무선인터넷 통신시스템으로 구성된다. 기존 제품은 각 엔진마다 압력센서를 설치하고 이를 감시모듈에서 실시간으로 계측한 후 통신에 의해 현장 제어실 PC나 Web 상에서 모니터링이 가능하지만 많은 샘플링 압력데이터 용량으로 인해 통신전송속도가 느려지고, 장기모니터링에 오류가 발생할 수 있다. 이와 같은 문제점을 개선하기 위하여 본 논문에서는 각 실린더별 압력센서에서 받은 원본 압력데이터는 NAS에 저장하고, 원본 압력데이터를 구간별 다운샘플링을 하여 제어실에서 장기모니터링하고, Web에서의 장기모니터링을 위하여 다운샘플 데이터를 무선전송 한다. 제안한 방식에서는 전송량을 1/10로 하였으므로 작은 용량을 가진 메모리를 사용할 수 있고, 빠른 통신속도를 유지할 수 있어 통신비용이 절감되며, 화면전체에 약 30일간의 장기모니터링이 가능하여 엔진의 유지관리에 큰 기여를 할 수 있을 것으로 사료된다.

환경 모니터링을 위한 압력 센서 연구 (A Study of Pressure Sensor for Environmental Monitoring)

  • 황현석;최원석
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권2호
    • /
    • pp.225-229
    • /
    • 2011
  • 본 연구에서는 환경 모니터링을 위한 정전용량형 압력센서를 저온동시소성세라믹 (LTCC) 기술을 이용하여 제작하였다. LTCC 기술은 실리콘 기반의 기술에 비하여 낮은 생산 단가, 높은 수율, 3차원 구조물의 용이한 제작성 등으로 인하여 센서 응용분야에서 중요한 역할을 담당하고 있으며, 특히 열악한 외부환경에 적합한 물질이다. 400 ${\mu}m$ 두께 삼차원 구조의 LTCC 다이어프램은 NEG사의 MLS 22C 상용 파우더를 이용하여 100 ${\mu}m$ 두께의 그린쉬트를 적층하고 동시소결하여 제작하였다. 제작한 다이어프램은 공동의 면적에 따른 센싱특성을 평가하기 위하여 각각 25, 49 $mm^2$의 두 종류를 제작하였다. 정전용량형 압력센서를 구현하기 위하여 상부에는 열증착기를 이용하여 Au 금속박막을 증착하였고 하부에는 상용 알루미늄막을 압착하였다. 압력에 따른 센싱특성을 평가하기 위하여 제작된 측정시스템을 이용하여 0~30 psi의 압력을 가변하여 압력센서의 정전용량 변화를 측정한 결과 두 센서 모두에서 선형적인 센싱 특성을 나타냄을 확인하였다.

Beamforming을 이용한 TPMS 간섭제거 (TPMS Interference Suppression Based on Beamforming)

  • 황석승;김성민;박철
    • 한국전자통신학회논문지
    • /
    • 제6권2호
    • /
    • pp.180-185
    • /
    • 2011
  • TPMS(Tire Pressure Monitoring System)는 차량의 주행 또는 정차시 타이어의 압력 또는 온도 등에 따른 이상 유무를 측정하여 수신기의 표시장치에 해당 상황을 나타내주도록 설계된 안전 보조 시스템이다. TPMS의 센서부에서 측정한 데이터를 자동차 내부의 신호처리부로 무선통신을 이용하여 전송하는데, 통신 시에 다양한 간섭으로 인한 통신 장애가 발생할 수 있다. 대표적인 TPMS 간섭으로 아마추어 무선국, 컨테이너 관리용 RFID(Radio-Frequency IDentification), RKE(Remote Keyless Entry) 신호 등을 들 수 있다. 이러한 다양하면서도 높은 전력을 가지는 간섭들을 제거하기 위하여 본 논문에서는 빔형성(Beamforming) 기술을 고려한다. 이에 따른 데이터 구조 및 빔형성기에 알맞는 차량내부의 안테나 배치 등을 제안한다. 컴퓨터 시뮬레이션을 통하여 본 논문에서 제안된 기술의 간섭제거 성능을 확인 할 것이다.

현장계측과 수치해석에 의한 농업용저수지 제체의 안정성 평가 (Safety Evaluation of Agricultural Reservoirs due to Raising Embankment by Field Monitoring and Numerical Analysis)

  • 이광솔;이달원;이영학
    • 한국농공학회논문집
    • /
    • 제58권2호
    • /
    • pp.31-44
    • /
    • 2016
  • This study analyzed pore water pressure, earth pressure and settlement through field monitoring on the project site in which raising embankments are being built through backside extension, and compared the behaviors of seepage analysis, slope stability analysis and stress-strain during flood water levels and rapid drawdown under steady state and transient condition. The variation of pore water pressure showed an increase during the later period in both upstream and downstream slope, with downstream slope more largely increased than upstream slope overall. The variation of earth pressure increased according to the increase of embankment heights, while the change largely showed in the upstream slope, it was slowly increased in the downstream slope. The settlements largely increased until 23 m as embankment heights increased, and showed very little settlement overall. Under a steady state and transient conditions, the seepage quantity per day and leakage quantity per 100 m of embankment against total storage were shown to be stable for piping. The hydraulic gradient at the core before and after raising embankments was greater than the limit hydraulic gradient, showing instability for piping. The safety factor of upstream and downstream slopes were shown to be very large at a steady state, while the upstream slopes greatly decreased at a transit conditions, downstream slopes did not show any significant changes. The horizontal settlements, the maximum shear strain and stress are especially distributed at the connecting portion of the existing reservoir and the new extension of backside. Accordingly, the backside extension method should be designed and reinforced differently from the cases of other types reservoirs.

지반구조물 계측센서의 내구연한 기준에 대한 분석적 연구 (An Analytical Study on the Durability Standard of Ground Structures Monitoring Sensors)

  • 우종태
    • 한국재난정보학회 논문집
    • /
    • 제17권1호
    • /
    • pp.53-59
    • /
    • 2021
  • 연구목적 및 방법: 본 논문은 지반구조물 계측센서의 내구연한 기준에 대한 분석적 연구로 국내 건설공사 발주기관의 건설 계측센서에 대한 내구연한 기준과 조달청의 건설계측 및 건설기계 관련 내용연수 기준을 분석하였다. 연구결과: 지반구조물에 설치되기 전 조달청에서 물품 자체로 구매하는 경사계와 변형률계 등의 내구연한 기준은 8년에서 10년을 제시하고 있다. 결론: 국내외 댐에 설치된 각종 계측센서의 신뢰성 비교를 통한 실제적인 내구연한 분석과 터널에 설치된 유지관리 계측센서의 경과연수에 대한 손망실율 등을 종합 검토한 결과 구조물이나 지반에 설치된 국내 간극수압계 및 토압계 등의 매립식 계측센서의 적정 내구연한은 5년에서 8년이 합리적인 것으로 판단된다.

생체 임피던스 방법을 이용하여 복압을 측정하기 위한 최적 전극위치 선정 (Optimum Electrode Selection for Measuring Abdominal Pressure using Bio-Impedance Method)

  • 김거식;이상옥;서정환;김경섭;송철규
    • 전기학회논문지
    • /
    • 제56권7호
    • /
    • pp.1339-1342
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method and compared with conventional methods. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2+0.0620x+0.6958$, respectively. It demonstrated that the abdominal pressure could be measured noninvasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

중증 뇌동맥류 환자의 조기 수술에 있어서 뇌압 측정의 중요성 (Significance of Intracranial Pressure Monitoring in Early Surgery for Poor-Grade Aneurysm Patients)

  • 김상수;김종문;강성돈
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권4호
    • /
    • pp.425-429
    • /
    • 2001
  • Objective : Patients with poor grade aneurysm usually present with increased intracranial pressure(ICP), even those without an intracranial clot. Based on this fact, the present study investigated a significance of intracranial pressure monitoring in those patients. Patients and Methods : A total of 60 patients with Hunt and Hess Grade IV(50 patients) or V(10 patients) were treated for aneurysmal subarachnoid hemorrhage(SAH) during a 3-year-period, and intraparenchymal ICP was measured in the majority, immediately after arrival to the emergency room. Early surgery including intraoperative ventriculostomy was undertaken within 3 days after SAH. An ultraearly surgery was performed without preceding angiogram or ICP monitoring in patients with large sylvian hematomas, highly suggestive of middle cerebral artery aneurysm. Outcomes were assessed by the Glasgow Outcome Scale(GOS) at 6 months. Results : In overall, favorable outcome(GOS scores 1-2) was seen in 27(54.0%) of admission Grade IV and 1(10.0%) of admission Grade V patients. Of the 38 surgical patients with preoperative ICP monitorings, 25 patients (80.6%) exhibiting ICP values of less than 40mmHg showed favorable outcome, however, no patients with ICP values above 40mmHg recovered(Fisher's exact test, p=0.0001). Conclusion : It is concluded that a preoperative ICP above 40mmHg before ventriculostomy indicate significant vital brain destruction as intractable intracranial hypertension, and Grade IV patients at admission with an ICP below 40mmHg can be of benefit from early surgical intervention while Grade V patients still remains unfavorable.

  • PDF