• Title/Summary/Keyword: Pressure Modulator

Search Result 48, Processing Time 0.027 seconds

Low-Voltage Current-Sensing CMOS Interface Circuit for Piezo-Resistive Pressure Sensor

  • Thanachayanont, Apinunt;Sangtong, Suttisak
    • ETRI Journal
    • /
    • v.29 no.1
    • /
    • pp.70-78
    • /
    • 2007
  • A new low-voltage CMOS interface circuit with digital output for piezo-resistive transducer is proposed. An input current sensing configuration is used to detect change in piezo-resistance due to applied pressure and to allow low-voltage circuit operation. A simple 1-bit first-order delta-sigma modulator is used to produce an output digital bitstream. The proposed interface circuit is realized in a 0.35 ${\mu}m$ CMOS technology and draws less than 200 ${\mu}A$ from a single 1.5 V power supply voltage. Simulation results show that the circuit can achieve an equivalent output resolution of 9.67 bits with less than 0.23% non-linearity error.

  • PDF

A development of auto-ranging and diagnostic method of thyratron (싸이라트론의 진단 및 자동 조절 장치 개발)

  • Kim, S.H.;Park, S.S.;Han, Y.J.;Kim, S.C.;Nam, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2129-2131
    • /
    • 2000
  • The thyratron is a very important device in the modulator as the high power switch but there is no method to diagnose the inside of the thyratron. The thyratron always require ranging, maintaining of the proper pressure, for the optimum operation of the thyratron. But, up to now this only depends on the experience of the operator. In this paper, we discuss the diagnostic of the thyratron by the convection heat current and the principle and experimental data will be compared for the automatical adjustment of optimum gas pressure of the thyratron at the intial stage.

  • PDF

A Study on the Modeling of Solenoid Valve for Anti - lock Brake System (미끄럼 방지 제동장치용 솔레노이드 밸브의 모델링에 관한 연구)

  • Song, Chang-Seop;Yang, Hae-Jeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.12
    • /
    • pp.81-90
    • /
    • 1995
  • Anti-lock Brake System has been developed to reduce tendency for wheel lock and improve vehicle control during sudden braking on slippery road surfaces. This is achieved by controlling the braking pressure avoiding wheel lock, while retaining handling and brake performance. This paper is concerned about characteristics of a solenoid valve in hydraulic modulator for controlling brake pressure. First, it was modeling the electromagnet by the permeance method. Second, it was modeling the commercial Maxwell poackage program. And then, a experiment was performed in order to justify modeling. The result of modeling coincided with teh result of experiment and commercial packabe program. As a result, these modelings will be able to use in analysis of dynamic character- istics of the solenoid valve for braking.

  • PDF

Static Characteristics of Micro Gas-Lubricated proceeding Bearings with a Slip Flow (미끄럼 유동을 고려한 초소형 공기 베어링의 정특성)

  • Kwak, Hyun-Duck;Lee, Yong-Bok;Kim, Chang-Ho;Lee, Nam-Soo;Choi, Dong-Hoon
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.137-142
    • /
    • 2002
  • The fluid mechanics and operating conditions of gas-lubricated proceeding bearings in micro rotating machinery such as micro polarization modulator and micro gas turbine are different from their larger size ones. Due to non-continuum effects, there is a slip of gas at the walls. Thus in this paper, the slip flow effect is considered to estimate the pressure distribution and load-carrying capacity of micro gas-lubricated proceeding bearings as the local Knudsen number at the minimum film thickness is greater than 0.01. Based on the compressible Reynolds equation with slip flow, the static characteristics of micro gas-lubricated proceeding bearings are obtained. Numerical predictions compare the pressure distribution and load capacity considering slip flow with the performance of micro proceeding bearings without slip f]ow for a range of bearing numbers and eccentricities. The results clearly show that the slip flow effect on the static characteristics is considerable and becomes more significant as temperature increases.

  • PDF

Study on the Characteristics of Control by High Frequency ECU for Braking System (제동 시스템을 위한 고주파수 ECU의 제어 특성 연구)

  • Yeon, Kyu-Bong;Chong, Jong-Wha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2428-2434
    • /
    • 2012
  • This paper describes the control of a solenoid valve of ESC(Electronic Stability Control) with hydraulic modulator in braking system. ESC ECU(Electronic Control Unit) to control the high-frequency control and slope control method was applied, the surge pressure and EMI(electromagnetic interference) reduction characteristics were studied. The stage of ECU output was added the slope shaping function to reduce electromagnetic emission at higher frequencies. Measurements show that this high frequency ECU manages to reduce the surge pressure and electromagnetic emission by the control of solenoid valve. In conclusion, by using the results of this study for the high frequency ECU control, we could expect enhancement of braking system performance.

Association of PPARGC1A Gene Variants with Hypertension in Korean Population

  • Jin, Hyun-Seok;Park, Sangwook
    • Biomedical Science Letters
    • /
    • v.27 no.1
    • /
    • pp.12-18
    • /
    • 2021
  • Hypertension (HTN) is one of the cardiovascular disease risk factors. Peroxisome proliferator-activated receptor γ coactivator 1 alpha (PPARGC1A) is involved in a master modulator of mitochondrial biogenesis, and pulmonary arterial hypertension. In this study, we report results of PPARGC1A were associated with hypertension and its intermediate phenotype of systolic (SBP) and diastolic blood pressure (DBP) in the Korean population. In detail, identifying a susceptibility locus, 3 SNPs for HTN, 2 SNPs for SBP, 3 SNPs for DBP at P<0.05. Among them, rs1472095 in PPARGC1A gene statistically demonstrated one of the significant correlations with Hypertension (P-value=0.00359, OR=0.8, 95% CI=0.68~0.93). The minor allele (T) of PPARGC1A was statistically associated with the increased value of DBP, SBP, and the increase risk of hypertension. We aim to manifest a significant association between genetic variant in PPARGC1A and hypertension. This finding suggested that association of PPARGC1A genetic polymorphism and HTN accelerates our understanding of blood pressure control and underlines potential drug targets for treatment of hypertension.

Rg3-enriched Korean Red Ginseng enhances blood pressure stability in spontaneously hypertensive rats

  • Nagar, Harsha;Choi, Sujeong;Jung, Saet-byel;Jeon, Byeong Hwa;Kim, Cuk-Seong
    • Integrative Medicine Research
    • /
    • v.5 no.3
    • /
    • pp.223-223
    • /
    • 2016
  • Background: Korean Red Ginseng (Panax ginseng) has been shown to exert antihypertensive effects. In particular, ginsenoside Rg3 is thought to be a potent modulator of vascular function. The present study was performed to examine the antihypertensive efficacy of Korean Red Ginseng (KRG) extract and Rg3-enriched KRG (REKRG) extract. Methods: Spontaneously hypertensive rats (SHRs) andWistar-Kyoto rats (WKYs) were divided into six groups (WKY control, WKY-KRG, WKY-REKRG, SHR control, SHR-KRG, and SHRREKRG), and systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured at the carotid artery, followed by injection of 3mg/kg KRG or 3mg/kg REKRG. Results: REKRG treatment significantly decreased SBP and DBP 3hours post-treatment in the SHR group compared with SHR control group. However, SBP and DBP were not significantly different in KRG-treated SHRs compared with control SHRs. REKRG treatment did not significantly alter SBP or DBP 3hours post-treatment in the WKY group compared with WKY control group. Similarly, there were no differences in SBP or DBP with KRG treatment in the WKY group and WKY control group. Both KRG and REKRG increased endothelial nitric oxide synthase phosphorylation levels in the aorta, and the increases in endothelial nitric oxide synthase phosphorylation levels by REKRG treatment were higher than those with KRG treatment. Similarly, nitric oxide production in plasma from WKYs and SHRs was also increased by both KRG and REKRG. Conclusion: These results suggest that REKRG has a more beneficial effect on blood pressure control than KRG in SHRs.

A Study on the Combustion and Performance Characteristics in Compression Ignition CRDI Diesel Engine (직접분사식 압축착화 디젤엔진의 분사시기 변화에 따른 연소 및 성능특성에 관한 연구)

  • Kim, Gi-Bok;Kim, Chi-Won;Yoon, Chang-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.19 no.1
    • /
    • pp.31-38
    • /
    • 2016
  • Since the oil shock of 1970's there was a strong upward tendency for the use of the high viscosity and poorer quality fuels. Therefore the misfiring engine occurs due to the decrease of quantity injected for lean burn and emission control in Compression Ignition Common Rail Direct Injection diesel engine. In this study, it is designed and used the test bed which is installed with fuel injector controller. In addition to equipped engine using CRDI by controlling the injection timing with mapping modulator, it has tested and analyzed the engine performance and combustion characteristics, as it is varied that they are the operating parameters: fuel injected quantity, engine speed and injection timing.

Fabrication of Large Area Transmission Electro-Absorption Modulator with High Uniformity Backside Etching

  • Lee, Soo Kyung;Na, Byung Hoon;Choi, Hee Ju;Ju, Gun Wu;Jeon, Jin Myeong;Cho, Yong Chul;Park, Yong Hwa;Park, Chang Young;Lee, Yong Tak
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.220-220
    • /
    • 2013
  • Surface-normal transmission electro-absorption modulator (EAM) are attractive for high-definition (HD) three-dimensional (3D) imaging application due to its features such as small system volume and simple epitaxial structure [1,2]. However, EAM in order to be used for HD 3D imaging system requires uniform modulation performance over large area. To achieve highly uniform modulation performance of EAM at the operating wavelength of 850 nm, it is extremely important to remove the GaAs substrate over large area since GaAs material has high absorption coefficient below 870 nm which corresponds to band-edge energy of GaAs (1.424 eV). In this study, we propose and experimentally demonstrate a transmission EAM in which highly selective backside etching methods which include lapping, dry etching and wet etching is carried out to remove the GaAs substrate for achieving highly uniform modulation performance. First, lapping process on GaAs substrate was carried out for different lapping speeds (5 rpm, 7 rpm, 10 rpm) and the thickness was measured over different areas of surface. For a lapping speed of 5 rpm, a highly uniform surface over a large area ($2{\times}1\;mm^2$) was obtained. Second, optimization of inductive coupled plasma-reactive ion etching (ICP-RIE) was carried out to achieve anisotropy and high etch rate. The dry etching carried out using a gas mixture of SiCl4 and Ar, each having a flow rate of 10 sccm and 40 sccm, respectively with an RF power of 50 W, ICP power of 400 W and chamber pressure of 2 mTorr was the optimum etching condition. Last, the rest of GaAs substrate was successfully removed by highly selective backside wet etching with pH adjusted solution of citric acid and hydrogen peroxide. Citric acid/hydrogen peroxide etching solution having a volume ratio of 5:1 was the best etching condition which provides not only high selectivity of 235:1 between GaAs and AlAs but also good etching profile [3]. The fabricated transmission EAM array have an amplitude modulation of more than 50% at the bias voltage of -9 V and maintains high uniformity of >90% over large area ($2{\times}1\;mm^2$). These results show that the fabricated transmission EAM with substrate removed is an excellent candidate to be used as an optical shutter for HD 3D imaging application.

  • PDF

Pharmacological Evidence that Calcitonin Gene-Related Peptide is Implicated in Cerebral Autoregulation

  • Hong, Ki-Whan;Pyo, Kwang-Min;Yu, Sung-Sook;Rhim, Byung-Yong
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.04a
    • /
    • pp.287-287
    • /
    • 1994
  • In the present study, it was aimed to asses the possibility that calcitonin gene-related peptide (CGRP) released in response to transient hypotension may contribute to the reflex autoregulation of cerebral blood flow as a putative modulator. Changes in pial arterial diameter (mean, 33.0 ${\pm}$ 1.1 $\mu\textrm{m}$) with changes in systemic arterial blood pressure (mean, 101.9 ${\pm}$ 2.7 mmHg) were observed directly through a closed cranial window in anesthetized normotensive rats. Image of the pial vessels was captured with a stereoscope connected to a CCD video camera and the diameter was measured with a microscaler. In the capsaicin-treated rats (one day prior to experiment, 50 nmol capsaicin injected intracisternally), both vasodilater and vasoconstrictor responses evoked by a transient hypotension and the reverse of blood pressure were markedly attenuated or almost abolished. When changes in pial arterial diameter were plotted as a function of changes in blood pressure, the slopes of both regression lines (for vasodilators and vasoconstrictors ) were markedly reduced. Similar reductions were evidenced under treatment wi th the CGRP antibody serum (1:1,000) and following CGRP receptor desensitization. However, the autoregulatory mechanics were neither affected by treatment wi th spantide (1 ${\mu}$M), substance P antagonist, nor by substance P receptor desensitization. Suffusion wi th mock cerebrospinal fluid containing CGRP and cromakalim caused a vasodilatation in a concentration-dependent manner, respectively and their effects were antagonized by glibenclamide. Substance P produced a vasodilatation, which was, however, little affected by glibenclamide. These observations indicate that the CGRP released from the perivascular sensory fibers in response to a hypotension is implicated in the modulation of the autoregulation of cerebral blood flow.

  • PDF