• Title/Summary/Keyword: Pressure Medium

Search Result 797, Processing Time 0.031 seconds

The Simulation about the Air Flow and Pressure Drop inside the Metal Foam (발포 금속 내 공기 유동 및 압력강하에 관한 시뮬레이션)

  • Kim, Pil-Hwan;Jin, Mei-Hua;Jang, Seok-Jun;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1053-1058
    • /
    • 2008
  • Porous medium was considered in the present study for the heat transfer enhancement. This was attributed to its high surface area to volume ratio as well as intensive flow mixing by tortuous flow passages. But when the air or water flow through in the porous medium, it is occurred the pressure drop between inlet and outlet. So in the present study investigated simulation result about the pressure drop in the porous medium before apply to heat exchanger. In this simulation, the thickness of the solid inside the porous medium region was varied 0.2 mm to 0.4 mm. And then the simulation result were compared the pressure drop in the same unit cell ($0.5\;mm{\times}0.5\;mm{\times}0.5\;mm$). To make the analysis model, it was assumed the 14-sided tetrakaidecahedron cell which has long been considered the optimal packing cell first proposed by the Lord Kelvin in 1887. And then the simulation is carried out using by STAR-CCM+ which is commercial software. The simulation result can be showed quantified pressure drop by solid effect in the porous medium.

  • PDF

Variations of Temperature and Pressure in the Cavity for Operational Conditions of Injection Molding (사출성형의 공정변수에 따른 캐비티 내의 온도와 압력의 변화)

  • Kim S. W.;Park H. C.;Lyu M.-Y.;Jin Y. S.;Kim D.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.70-74
    • /
    • 2004
  • Pressure and temperature in the cavity of injection molding have been investigated. Special injection mold was designed to install pressure and temperature sensors. The sensors were supplied by KISTLER and the pressure and temperature were measured for various operational conditions, such as injection pressure, holding pressure, cooling time, mold temperature, and injection temperature. As injection pressure increased cavity pressure and temperature increase. There were no big differences in temperatures according to the holding pressures. As mold temperature increased pressure and temperature in the cavity increase. The flowability of resin increases as mold temperature increases subsequently the pressure in the cavity increases since the pressure loss is less in the low viscous medium than high ciscous medium. The cavity temperature highly depends upon mold temperature.

  • PDF

Heat Transfer Characteristics in a Cylindrical Duct Packed with Solid Spheres

  • Lee, Seung-Hyuk;Kang, Kwan-Gu;Kim, Sung-Chan;Ryou, Hong-Sun;Noh, Dong-Soon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.1
    • /
    • pp.11-21
    • /
    • 2005
  • The present paper investigates the heat transfer characteristics in a cylinder packed with porous medium of solid spheres for various parameters such as mass flow rate, sphere diameter, length of the porous medium, and gas temperatures. Pressures and temperatures at the inlet and outlet regions were measured by using static pressure gages and R-type thermocouples. The modified relationship based on the Ergun equation is suggested for the estimation of pressure drops. In addition, the useful empirical correlation for thermal efficiency is obtained in the current study. Thermal efficiency is expressed in terms of non-dimensional time, sphere diameter, porosity, and pressure drops. It is also found that the pressure drop through the cylinder becomes larger as the gas temperature does higher at the inlet region, whereas it substantially decreases when the inlet flow rate decreases.

A Numerical Study on Pressure Drop and Flow Characteristics in Pleated Filters (절곡필터에서의 압력강하 및 유동특성에 관한 수치적 연구)

  • Lee, Jae-Heon;Chung, S.H.;Cho, S.J.;Kim, K.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.3
    • /
    • pp.176-185
    • /
    • 1991
  • Pressure drop and flow characteristics through a filter medium have been investigated numerically. A basic model similar to the filter employed in a hard disk drive was established so that the inflow velocity was 0.1 m/s and the box size was $40mm{\times}50mm{\times}30mm$. The filter medium specifications were 0.38mm of thickness, $1{\mu}m$ of fiber diameter, 0.05 of packing density. And the filter medium was pleated by 10 within the filter box. Twenty-one sets of calculation were performed with different inlet velocities, pleated numbers, and packing densities from the basic model. As the result, it was found that the velocity after filter medium had maximum value at the rear of the upstream pleated line, but had minimum value at the rear of the downstream pleated line. This made the velocity distribution have sinusoidal form immediately after the filter medium. As the inlet velocity increased, the pressure drop increased linearly. But as the packing density increased the pressure drop increased quadratically.

  • PDF

Numerical analysis of condensation in the condenser using the porous medium approach (다공성 매질 개념을 이용한 응축기의 응축 열전달에 관한 수치 해석)

  • Je, Jun-Ho;Choi, Chi-Woong;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2261-2266
    • /
    • 2007
  • In this study, the numerical analysis to estimate condensation heat and mass transfer of the condenser was carried out using the PMA (porous medium approach). In the PMA, the details of tube bundle in the condenser are replaced by the porous medium, and the flow resistance term is added in the momentum equation. In this regard, the PMA is quite helpful for the study of tube bundle in the large condenser. The pressure loss through tube bundle can be compensated by viscous and inertial momentum sink terms, which was validated numerically. Value of the pressure drop was compared to that of Butterworth correlation. Three dimensional analysis of condensation for McAllister condenser with the PMA was conducted using Fluent 6.2 and UDFs (use-defined functions). The result of condensation rate was analogous to previous results (experimental and numerical data).

  • PDF

On Numerical Treatment of Pressure Gradient at the Interface Between a Homogeneous Fluid and a Porous Medium (순수유체와 다공성물질의 경계면에서 압력구배의 수치적 처리에 관하여)

  • Kim I. S.;Nam J. H.;Kim C.-J.
    • Journal of computational fluids engineering
    • /
    • v.4 no.3
    • /
    • pp.28-34
    • /
    • 1999
  • The objective of this study is to present a numerical treatment of the pressure gradient when control volumes are sharing the interface between a homogeneous fluid and a porous medium. Two possible approaches, e.g. linear interpolation and extrapolation, are considered, and they are applied to the case of a steady and two-dimensional curved channel flow which is partially filled with a porous medium. It was found that the linear extrapolation produces a continuous velocity-field at the interface and thus is recommended. On the contrary, the linear interpolation entails a discontinuous velocity field at the interface, thereby warning its use in connection with the Brinkman-Forchheimer-extended Darcy flow model.

  • PDF

Pressure Contact Interconnection for High Reliability Medium Power Integrated Power Electronic Modules

  • Yang, Xu;Chen, Wenjie;He, Xiaoyu;Zeng, Xiangjun;Wang, Zhaoan
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.544-552
    • /
    • 2009
  • This paper presents a novel spring pressure contact interconnect technique for medium power integrated power electronics modules (IPEMs). The key technology of this interconnection is a spring which is made from Be-Cu alloy. By means of the string pressure contact, sufficient press-contact force and good electrical interconnection can be achieved. Another important advantage is that the spring exhibits excellent performance in enduring thermo-mechanical stress. In terms of manufacture procedure, it is also comparatively simple. A 4 kW half-bridge power inverter module is fabricated to demonstrate the performance of the proposed pressure contact technique. Electrical, thermal and mechanical test results of the packaged device are reported. The results of both the simulation and experiment have proven that a good performance can be achieved by the proposed pressure contact technique for the medium power IPEMs.

A study on medium-low pressure gauge for domestic production (중.저기압 압력계의 국산화에 관한 연구)

  • 백용현
    • 전기의세계
    • /
    • v.29 no.8
    • /
    • pp.519-523
    • /
    • 1980
  • The traditional mechanical manometer is improved to develop more convenient and precise manometer in continuous measurement of the gas pressure in medium-low vacuum range (1x10$^{-1}$ -10 Torr.) Glass (solid) is used as a detector material of the improved manometer. Using the strain gauge adhered to thin glass board, mechanical strain corresponding to variation of pressure in measurement system is converted into quantity of electricity, and the quantity of electricity is amplified. Experiments have also shown that the improved manometer have more advantages in reproducibility, measured sensibility, and responsible velocity than taditional one.

  • PDF

An Experimental Study on the Pressure Range of Fire Cupping Method

  • An, Soo Kwang;Kim, Ku Weon;Lee, Ha Lim;Lee, Tae Wook;Kim, Eun Seok;Lee, Byung Ryul;Yang, Gi Young
    • Journal of Acupuncture Research
    • /
    • v.38 no.3
    • /
    • pp.200-204
    • /
    • 2021
  • Background: Standardized procedures for the clinical application of fire cupping methods have not been established. In particular, the pressure parameters have not been fully characterized and described. Therefore, using various materials, this study investigated the pressure range exerted during fire cupping therapy. Methods: In this study, 3 differently sized (small, medium, large) glass and bamboo cups were used in the cotton ball fire cupping procedure to measure the pressure inside the cup applied to a human skin model. The pressure in each cup was measured 15 times for a total of 90 measurements. Results: A small bamboo cup had the minimum overall pressure (-305.4 mmHg), whereas the large glass cup exerted the maximum pressure (-401.3 mmHg), followed by the medium glass cup, large bamboo cup, small glass cup, and medium bamboo cup. The average pressure exerted by the cotton ball method for all cups ranged from -348.715 mmHg to -358.694 mmHg (95% confidence interval). Overall, the glass cups had a greater pressure than the bamboo cups in all groups (p < 0.001). Among the glass cups used, the larger the size of the cup, the higher the average pressure detected (-381.947 mmHg to -391.973 mmHg; p < 0.05). Conclusion: Large glass cups which are widely used in clinical practice, when used in the fire cupping method exerted pressure ranging from -381.947 mmHg to -391.973 mmHg (95% CI).

A Study on the Emission Characteristics of NOx in Medium Speed Diesel Engine (중속 디젤기관의 질소산화물 배출특성에 관한 연구)

  • 우석근;윤건식;윤영환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.526-534
    • /
    • 2000
  • In this study, the characteristics of exhaust emissions in medium speed diesel engine under various operating conditions were investigated through experiments to derive the optimum conditions for minimizing the exhaust emissions, especially, nitrogen oxides. The 355 KW$\times$1200 rpm medium speed diesel engine was intensively examined to investigate the trend of exhaust emissions in case that the parameters affecting combustion conditions such as fuel injection timing, intake air temperature and pressure, engine speed and load were changed. The exhaust emissions for 9 sets of medium speed diesel engine were analyzed in addition. From this study, NOx level could be reduced by 30~50% through the adjustment of retarded fuel injection timing, lowered intake air temperature and increased charging air pressure.

  • PDF