• 제목/요약/키워드: Pressure Exchange

검색결과 389건 처리시간 0.029초

Structural and Magnetic Properties of the Brownmillerite $Ca_2Al_xFe_{2-x}O_5$ System

  • 김귀야;로권선;여철현
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권10호
    • /
    • pp.934-938
    • /
    • 1995
  • A series of solid solutions in the Ca2AlxFe2-xO5 (x=0.00, 0.50, 0.66, 1.00 and 1.34) system with brownmillerite structure has been synthesized at 1100 ℃ under an atmospheric air pressure. The solid solutions are analysed by powder x-ray diffraction analysis, Mohr salt titration, thermal analysis, and Mossbauer spectroscopic analysis. The x-ray diffraction analysis assigns the compositions of x=0.00 and 0.50 to the space group Pcmn and those of x=0.66, 1.00, and 1.34 to the Ibm2. Mo&ssbauer spectra have shown the coordination state and disordering of Al3+ and Fe3+ ions. The substituting preference of Al3+ ions for the tetrahedral site decreases with increasing x value. Magnetic susceptibility of the system has been measured in the temperature range of 5 K to 900 K. The solid solutions of the compositions of x=0.00, 0.50 and 0.66 have shown a thermal hysteresis and the thermoremanent magnetization gap decreases with increasing x value in the above systems. However the compositions of x=1.00 and 1.34 do not show the hysteresis. The exchange integral is calculated from Fe3+ ion occupancy ratio. The integral decreases with x value and thus the magnetic transition temperature decreases with the increasing x value.

소형 공동주택의 하이브리드 환기시스템 성능실험 연구 (A Study on the Performance Evaluation of the Hybrid Ventilation System for Small Apartment Houses)

  • 전주영;김길태;이종성;김상희
    • 설비공학논문집
    • /
    • 제20권10호
    • /
    • pp.696-701
    • /
    • 2008
  • From Feb. 2006, the ventilating systems with air exchange rate of over 0.7times/hour are installed at the apartment houses (over 100 units). Installation cost and maintenance cost are very important factors for ventilating system because consumers have to pay the expenses of that system. Especially small apartment needs more considerations because small apartment is comparatively the economically weak part. The purpose of this study is to the performance evaluation of the hybrid ventilation system for small apartment houses. Hybrid system 1 consists of natural ventilation system and duct type exhaust diffusers. Hybrid system 2 has natural ventilation system and toilet exhaust system with static pressure fan. Infiltration of test apartment houses with ventilation system is under 0.1 times/hour. Mean air age of hybrid system 1 is 1.52 hours and hybrid system 2 is 1.42 hours. Mean ventilation effectiveness of hybrid system 2(93%) is higher than that of hybrid system 1(81%).

Purification of Biohydrogen Produced From Palm Oil Mill Effluent Fermentation for Fuel Cell Application

  • Rohani, Rosiah;Chung, Ying Tao;Mohamad, Izzati Nadia
    • Korean Chemical Engineering Research
    • /
    • 제57권4호
    • /
    • pp.469-474
    • /
    • 2019
  • Fermentation of palm oil mill effluent (POME) produces biohydrogen in a mixture at a specific set condition. This research was conducted to purify the produced mixed biohydrogen via absorption and membrane techniques. Three different solvents, methyl ethanolamine (MEA), ammonia ($NH_3$) and potassium hydroxide (KOH) solutions, were used in absorption technique. The highest $H_2$ purity was found using 1M MEA solution with 5.0 ml/s feed mixed gas flow rate at 60 minutes absorption time. Meanwhile, the purified biohydrogen using a polysulfone membrane had the highest $H_2$ purity at 2~3 bar operating pressure. Upon testing with proton exchange membrane fuel cell (PEMFC), the highest current and power produced at 100% $H_2$ were 1.66 A and 8.1 W, while the lowest were produced at 50/50 vol% $H_2/CO_2$ (0.32 A and 0.49 W). These results proved that both purification techniques have significant potential for $H_2$ purification efficiency.

Removal of iron oxide scale from feed-water in thermal power plant using superconducting magnetic separation

  • Nishijima, S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권2호
    • /
    • pp.22-25
    • /
    • 2019
  • The superconducting magnetic separation system has been developing to separate the iron oxide scale from the feed water of the thermal power plant. The accumulation in the boiler lowers the heat exchange rate or in the worst case damages it. For this reason, in order to prevent scale generation, controlling pH and redox potential is employed. However, these methods are not sufficient and then the chemical cleaning is performed regularly. A superconducting magnetic separation system is investigated for removing iron oxide scale in a feed water system. Water supply conditions of the thermal power plant are as follows, flow rate 400 t / h, flow speed 0.2 m / s, pressure 2 MPa, temperature $160-200^{\circ}C$, amount of scale generation 50 - 120 t / 2 years. The main iron oxide scale is magnetite (ferromagnetic substance) and its particle size is several tens ${\mu}m$. As the first step we are considering to introduce the system to the chemical cleaning process of the thermal power plant instead of the thermal power plant itself. The current status of development will be reported.

Study on bidirectional fluid-solid coupling characteristics of reactor coolant pump under steady-state condition

  • Wang, Xiuli;Lu, Yonggang;Zhu, Rongsheng;Fu, Qiang;Yu, Haoqian;Chen, Yiming
    • Nuclear Engineering and Technology
    • /
    • 제51권7호
    • /
    • pp.1842-1852
    • /
    • 2019
  • The AP1000 reactor coolant pump is a vertical shielded-mixed flow pump, is the most important coolant power supply and energy exchange equipment in nuclear reactor primary circuit system, whose steadystate and transient performance affect the safety of the whole nuclear island. Moreover, safety demonstration of reactor coolant pump is the most important step to judge whether it can be practiced, among which software simulation is the first step of theoretical verification. This paper mainly introduces the fluid-solid coupling simulation method applied to reactor coolant pump, studying the feasibility of simulation results based on workbench fluid-solid coupling technology. The study found that: for the unsteady calculations of the pure liquid media, the average head of the reactor coolant pump with bidirectional fluid-solid coupling decreases to a certain extent. And the coupling result is closer to the real experimental value. The large stress and deformation of rotor under different flow conditions are mainly distributed on impeller and idler, and the stress concentration mainly occurs at the junction of front cover plate and blade outlet. Among the factors that affect the dynamic stress change of rotor, the pressure load takes a dominant position.

The Impact of Ownership Structure and Audit Quality on Carbon Emission Disclosure: An Empirical Study from Indonesia

  • TARIGAN, Bahagia;PRAMONO, Agus Joko;RUSMIN, Rusmin;ASTAMI, Emita Wahyu
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제9권4호
    • /
    • pp.251-259
    • /
    • 2022
  • This study investigates the impact of ownership structures and audit quality on carbon emission disclosure. It also examines how audit quality affects the relationship between ownership structures and carbon emission disclosure. This research includes 106 standalone sustainability reports from non-financial companies that were listed on the Indonesia Stock Exchange (IDX) between 2015 and 2018. Our findings show that family and concentrated ownerships convey less information about carbon emissions. Our results fail to demonstrate that disclosure of carbon emissions could be a corporation's approach to respond to stakeholder pressure and public visibility and to provide legitimacy for its existence. We also find a positive and significant association between high-quality (Big4) auditors and carbon emission performance. Our further result suggests that Big4 auditors seem to compromise their high standard quality on auditing family and concentrated ownership firms. They fail to influence their family and concentrated ownership clients to be socially responsible. Policymakers should support the existence of Big4 auditors as a driver of carbon emission performance. Top management should be proactive to tackle carbon emission issues by adopting stakeholder-driven mechanisms and establishing legitimacy with society. Nevertheless, the involvement of family and highly concentrated shareholders in decision-making processes and information disclosure should not be encouraged.

급성호흡곤란증후군 환자에서 복와위(prone position)와 산화질소흡입(nitric oxide inhalation) 병용 치료의 효과 (The Combined Therapy of Inhaled Nitric Oxide and Prone Positioning Has an Additive Effect on Gas Exchange and Oxygen Transport in Patients with Acute Respiratory Distress Syndrome)

  • 고윤석;임채만;이기만;진재용;심태선;이상도;김우성;김동순;김원동
    • Tuberculosis and Respiratory Diseases
    • /
    • 제45권6호
    • /
    • pp.1223-1235
    • /
    • 1998
  • 연구배경 : 급성호흡곤란증후군(ARDS) 환자의 폐 산소화를 개선시키기 위한 보조적 치료법인 복와위 자세에서의 인공환기는 대상 환자의 약 61%에서, 흡입 산화질소 투여는 60-80%에서 효과가 있는 것으로 보고되어 있다. 산소화 호전의 주된 기전은 복와위시는 이환이 심한 등쪽 폐의 환기 호전에 의한 단락 감소이며, 산화질소 투여 시는 이환부위로부터 정상 폐포로의 폐 혈류의 재분포에 의한 단락 감소안 것으로 알려져 있다. 그러므로 복와위와 산화질소의 병용 치료 시 산소화 개선에 상승 효과를 기대할 수 있으나 이에 관한 임상 연구는 없었다. 이에 저자들은 ARDS환자에서 두 치료의 병합이 가스 교환 및 혈류 역학에 미치는 영향을 관찰하였다. 방 법 : ARDS 환자 12명(연령 $56{\pm}12$ 세, 남 : 여=9 : 3)을 대상으로 앙와위에서 호흡 및 혈류역학적 지표를 측정한 후 복와위로 전환하였다. 복와위 30분과 2시간에 동일 지표들을 측정한 뒤 산화질소를 투여하고 (5-10 ppm), 이후 30분, 2 시간 및 산화질소 투여 중단 후 10분에 각각 동일 지표들을 재 측정하였다. 결 과 : 가스 교환 지표 : 복와위에서 산화질소 병용 치료시, 앙와위 및 복와위에서보다 $PaO_2/FiO_2$가 증가되었고(각각 p< 0.01) 폐동맥혈 산소분압차($AaDO_2$)는 감소하였다(각각 p<0.005). 호흡 역학적 지표 : 폐 탄성, 호흡기계 탄성, 기도 저항 및 흡기말 기도압은 치료 방법에 따른 차이가 없었다. 혈류 역학적 지표 : 복와위에서 산화질소 병용 치료시, 앙와위 및 복와위에서보다 심 박출량 및 조직산소전달량($DO_2$)이 증가되었으며(각 P< 0.05), 폐혈관 저항, 평균 폐동맥압 및 폐동맥쐐기압은 감소되었다(각 P< 0.05). 결 론 : 급성호흡곤란증후군 환자에서 복와위 및 산화질소 홉업의 병용 치료는 복와위 단독 치료에 비해 폐산소화 호전에 상승 작용이 있으며, 조직으로의 산소 전달량도 증가시키므로 급성호흡곤란증후군 환자의 보조적인 치료법으로써 유용할 것으로 사료되었다.

  • PDF

액화석유가스 용기의 자연 증발량에 관한 연구 (A Study on the Natural Evaporation Capacity of LPG Container)

  • 조영도;김지윤
    • 한국가스학회지
    • /
    • 제5권2호
    • /
    • pp.22-29
    • /
    • 2001
  • 체적거래제에 의하여 소규모 공동주택에 가스를 공급하기 위하여 적절한 용기설치수의 결정 및 용기교체시기에 대한 검토가 필요하다. 그러나 지금까지 국내에 축적된 자료가 없을 뿐만 아니라 용기 설치수의 결정과 용기수 및 가스사용 형태에 따라 용기교체시 남아 있는 액화석유가스 양에 대한 이론적 검토가 없었다. 따라서 본 연구에서는 자연기화능력, 잔량, 용기의 온도, 용기내부 압력 등을 시뮬레이션으로 살펴보았다. 용기표면으로부터 액화석유가스 용기의 총괄 열전달계수의 변화에 따른 자연기화량 변화는 크지 않으며, 실험으로부터 구한 값은 약 $9{\~}13 kcal/m^2{\cdot}hr{\cdot}^{\circ}C$이었다. 그리고 액화석유가스 용기내부의 압력이 압력조정기의 압력조정 하한계에 도달하였을 때 가스방출 유량은 공기로부터 전달되는 열량과 균형을 이루는 일정한 값으로 급격히 감소하였다. LP가스용기의 자연기화능력은 외기온도 및 프로판의 조성에 따라 증가하였고, 연속사용시간에 따라 초기 급격히 감소하여 일정한 값으로 수렴하였다. 한 가구당 용기수는 자동절체기 사용에 의하여 감소시킬 수 있는 것을 알 수 있다.

  • PDF

추출방법에 따른 톳 추출물의 품질특성 (Quality characteristics of Hijikia fusiforme extracts with different extraction method)

  • 권유리;윤광섭
    • 한국식품저장유통학회지
    • /
    • 제22권1호
    • /
    • pp.70-77
    • /
    • 2015
  • 본 연구에서는 다양한 추출방법(열수, 가압가열, 초고압 추출방법)을 통해 톳 추출물을 제조하였으며 품질특성을 실시하여 효과적인 톳 추출방법을 제시하고자 하였다. 추출 수율은 초고압 추출물, 가압가열 추출물, 열수 추출물 순으로 높은 수율을 확인하였으며 색도의 경우 열수 추출물에서 높은 명도와 황색도를 나타내었고 가압가열 추출물에서는 적색도가 높았다. 추출방법에 따른 톳 추출물의 전당 함량을 측정한 결과, 전체적으로 모든 추출물이 40~60%의 높은 전당 함량을 보였으며 특히 가압가열 추출물의 함량이 높았다. 또한 시료별 전당 함량의 경우 가압가열, 열수, 초고압 추출물의 순으로 높은 함량을 보였으며 이는 환원당과 단백질 함량에서도 동일한 결과를 나타내었다. 그러나 우론산 및 총 아미노산 함량의 경우 초고압 추출물이 다른 추출물보다 높은 함량을 보였으며, 특히 asparagine의 경우 초고압 추출물에서만 검출되었다. 톳의 다당류 성분을 알아보고자 에탄올을 이용하여 조다당류를 추출한 결과 수율의 경우 초고압 추출물에서 4.75%로 높았으며 가압가열, 열수 추출물의 순으로 나타났다. 또한 high performance anion exchange chromatography를 통하여 조다당류의 구성당을 살펴본 결과 fucose가 주 당성분인 polysaccharide임을 알 수 있었으며 galactose, glucose, xylose가 함유되어 있음을 알 수 있었다. 이러한 결과를 종합해 볼 때 높은 온도와 압력을 가해 추출할 경우 해조류의 수율 및 유용성분의 추출이 용이해짐을 알 수 있었으며 추후 적절한 압력과 온도 설정관련 연구를 통해 해조 가공산업에 유용할 것으로 판단된다.

토끼의 정상 폐 모델에서 부분액체환기 시 가스교환에 영향을 주는 인자들에 대한 연구 (Evaluation of Parameters of Gas Exchange During Partial Liquid Ventilation in Normal Rabbit Lung)

  • 안창혁;고영민;박정웅;서지영;고원중;임성용;김철홍;안영미;정만표;김호중;권오정
    • Tuberculosis and Respiratory Diseases
    • /
    • 제52권1호
    • /
    • pp.14-23
    • /
    • 2002
  • 배 경 : 부분액체환기 (partial liquid ventilation; PLV) 시 최적의 기계환기의 설정에 대해서는 아직 논란이 많은 상태이다. 이에 정상 폐의 PLV 시 가스교환에 영향을 주는 인자들을 관찰함으로써, PLV 시 최적의 기계환기 설정을 확립하는 데에 이용하고자 본 연구를 시행하였다. 방 법 : New Zealand 산 백색 토끼 7 마리를 기계환기를 시행하였다. 기계환기는 압력 조절 양식으로 일회호흡량 ($V_T$) 8 mL/kg, PEEP 4 $cmH_2O$, 흡기대호기비 (I: E ratio) 1:2, 흡입산소분율 ($F_IO_2$) 0.75로 설정하였고, 호흡수(RR)는 $PaCO_2$가 35~45 mmHg 사이에 유지되도록 조절하였다. 이후 30분마다 기계환기기의 설정을 protocol에 따라 변화시키면서 가스환기(gas ventilation; GV)를 시행하였는데 ; (1) 기저 설정 단계, (2) 역비환기 (inverse I: E ratio) 단계로 I:E ratio 2:1, (3) 고 PEEP 단계로 2단계와 같은 평균흡기압 (MIP)을 유지하는 정도의 PEEP 증가, (4) 고 $V_T$ 단계로 $V_T$ 15 mL/kg, (5) 고RR 단계로 4단계와 같은 분당환기량 (MV)을 유지하는 정도로 RR을 증가시켰다. 그 후 perfluorodecalin 18 mL/kg 주입 후 상기 protocol과 동일하게 PLV를 하였다. 각각에서 동맥혈가스검사와 폐역학 및 혈역학적 지표를 측정하였다. 결 과 : (1) GV 시 $PaO_2$는 다섯 단계를 거치는 동안 의미 있는 변화를 보이지 않았다. $PaCO_2$는 고 $V_T$단계와 고 RR 단계에서 의미 있게 감소하였다(p<0.05). GV 시 폐역학 및 혈역학적 지표의 의미 있는 변화는 보이지 않았다. (2) PLV 군의 기저 $PaO_2$$312{\pm}113$ mmHg로 GV군의 $504{\pm}81$ mmHg 에 비해 의미 있게 낮았다(p=0.001). PLV 시 역비환기 단계나 고 RR 단계에서는 기저설정 단계와 비교하여 $PaO_2$의 의미 있는 차이가 관찰되지 않았으나, 고 PEEP 단계 ($452{\pm}38$ mmHg)와 고 $V_T$($461{\pm}53$ mmHg) 단계에서는 기저설정 단계보다 유의한 상승이 관찰되었다. (3) $PaCO_2$는 GV군과 PLV군 모두에서 고 $V_T$ 단계와 고 RR 단계에서 기저설정 단계보다 의미 있게 낮았다. PLV군의 기저설정 단계와 고 RR 단계의 $PaCO_2$는 GV 군보다 의미 있게 증가하였다(p<0.05). (4) PLV 시 폐역학 및 혈역학적 지표의 의미 있는 변화는 보이지 않았다 결 론 : 정상 폐에서 PLV 시 최적의 가스교환을 위해서는 적절한 PEEP과 $V_T$이 중용할 것으로 사료된다.