• 제목/요약/키워드: Pressure Cell

검색결과 1,809건 처리시간 0.027초

Measurement of red blood cell aggregation by analysis of light transmission in a pressure-driven slit flow system

  • Shin, S.;Park, M.S.;Jang, J.H.;Ky, Y.H.;Suh, J.S.
    • Korea-Australia Rheology Journal
    • /
    • 제16권3호
    • /
    • pp.129-134
    • /
    • 2004
  • The aggregation characteristics of red blood cells (RBCs) were measured using a newly developed light-transmission slit rheometer. Conventional methods of RBC disaggregation such as the rotational Couette system were replaced with a pressure-driven slit flow system with a vibrational mechanism. Using a vibration generator, one can disaggregate the RBC aggregates stored in the slit. While shear stress decreases exponentially, instantaneous pressure and the transmitted light intensity were measured over time. Applying an abrupt shearing flow after disaggregation caused a rapid elongation of the RBCs followed by loss of elongation with the decreasing shear stress. While the shear stress is further decreasing, the RBCs start to re-aggregate and the corresponding transmitted intensity increases with time, from which the aggregation indices can be obtained using a curve-fitting program.

2차원 소형 초음속 노즐 하류의 압축성 유동 구조 해석 (The Compressible flow structure behind the exit of a two-dimensional supersonic micro-nozzle)

  • 권순덕;김성초;김정수;최종욱
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.323-326
    • /
    • 2006
  • This paper presents the computational results for the two-dimensional compressible non-reacted flow in a converging-diverging micro thrust nozzle of which the ratio of exit to throat width (0.541 in.) is 1.8. The RNG model is applied to calculate the turbulence by loading the standard coefficients. The results agreed very well with the experiments in the view of the shock structure and the pressure distribution at the various pressure ratios between the stagnation and the environmental states. The plume structures are also discussed on the view of the shock-cell structure.

  • PDF

Flexible Display i Low Temperature Processes for Plastic LCDs

  • Han, Jeong-In
    • Transactions on Electrical and Electronic Materials
    • /
    • 제4권2호
    • /
    • pp.10-14
    • /
    • 2003
  • Flexible displays such as plastic-based liquid crystal displays (LCDs) and organic light-emitting diode displays (OLEDDs) have been researched and developed at KETI since 1997. The plastic film substrate is very weak to heat and pressure compared to glass substrate, that its fabrication process is limited to 110$^{\circ}C$ and low pressure. The ITO films were deposited on the bare plastic film substrate by rf-magnetron sputtering. Moreover, in order to maintain uniform cell gap and pressure on the plastic film substrate, we utilized newly-invented jig and fabrication process. Electro-optical characteristics were better than or equivalent to those of typical glass LCDs though it is thinner, lighter-weight, and more robust than glass LCDs.

원심압축기 베인 디퓨저에서의 선회실속 특성 (Characteristics of Rotating Stall in a Centrifugal Compressor with Vaned Diffuser)

  • 이두열;강창식;신유환;김광호
    • 한국유체기계학회 논문집
    • /
    • 제5권1호
    • /
    • pp.42-48
    • /
    • 2002
  • In this study, the instability of a centrifugal compressor with vaned diffuser was investigated. During unstable operation of the test compressor, pressure fluctuations at different diffuser radius ratios were measured by using high frequency pressure transducers. Two different types of stall, mild and deep stalls, were observed alternately and irregularly at some flow rates where the compressor performance was steeply deteriorated. In this transient zone, the size of rotating stall cell was estimated through the wavelet transform analysis. It was about 45 percents of rotor circumferential space at 300 rpm and not dependent on flow rate.

원심압축기 베인 디퓨저에서의 선회실속 특성 (Characteristics of Rotating Stall in a Centrifugal Compressor with Vaned Diffuser)

  • 이두열;강창식;신유환;김광호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.99-105
    • /
    • 2001
  • In this study, the instability of a centrifugal compressor with vaned diffuser was investigated. During unstable operation of the test compressor, pressure fluctuations at different diffuser radius ratios were measured by using high frequency pressure transducers. Two different types of stall, mild and deep stall, were observed alternately and irregularly at some flow rate where the compressor performance was steeply deteriorated. In this transient zone, the size of rotating stall cell was estimated through the Wavelet transform analysis. It was about 45 percents of rotor circumferential space at 3000 rpm and not dependent on flow rate.

  • PDF

C-D 노즐을 고려한 초음속 제트 소음 해석 (An Analysis of Supersonic Jet Noise with a Converging-Diverging Nozzle)

  • 김용석;이덕주
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2001년도 추계학술발표대회 논문집 제20권 2호
    • /
    • pp.389-392
    • /
    • 2001
  • To investigate the generation mechanism of the shock-associated noise, an underexpanded supersonic jet from an axisymmetic nozzle is simulated under the conditions of the Nozzle exit Mach number of 2 and the exit pressure ratio of Pe/Pe =1.5. The present simulation is performed based on the high-order accuracy and high-resolution ENO (Essentially Non-Oscillatory) scheme to capture the time-dependent flow structure representing the sound source. It was found that the shock-associated noise is generated by the weak interaction between the downstream propagating large turbulence structures of the jet flow and the quasi-periodic shock cell structure during the one is passing through the other. The directivity of propagating waves to the upstream is clearly shown in the visualization of pressure field. It is shown that the present calculation of the centerline pressure distribution is in fare agreement with the experimental data at the location of first shock cell.

  • PDF

연료전지용 공기공급기의 케이스 변형량 해석 및 개선설계 (Deformation Analysis and Design Modification of the case of the air blower for fuel cell)

  • 제우성
    • 한국기계기술학회지
    • /
    • 제13권4호
    • /
    • pp.43-48
    • /
    • 2011
  • The air blowers for fuel cell electric vehicle usually have big difference between inlet and outlet pressure. When the casing of the air blowers is designed, the stress analysis is required. (Approximately Inlet pressure is 0.5bar and outlet pressure is 2bar.) Gap distance between the casing and the impeller is 0.3mm. Therefore, if the amount of maximum deformation of casing is larger than 0.3mm, impeller crashed the casing. In order to avoid crashing, both the thickness and number of rims are changed and carried out simulations on each cases.

유로형상 및 운전조건에 따른 고분자 전해질 연료전지의 성능 특성 (Performance Characteristics of PEMFC by flow Configurations and Operating Condition)

  • 이필형;조선아;한상석;황상순
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3440-3445
    • /
    • 2007
  • For proton exchange membrane fuel cell, it is very important to design the flow channel on separation plate optimally to maximize the current density at same electrochemical reaction surface and reduce the concentration polarization occurred at high current density. In this paper, three dimensional computation model including anode and cathode domain together was developed to examine effects of flow patterns and operation conditions such as humidity and operating temperature on performance of fuel cell. Results show that voltage at counter flow condition is higher than that at coflow condition in parallel and interdigitated flow pattern. And fuel cell with interdigitated flow pattern which has better mass transport by convection flow through gas diffusion layer has higher performance than with parallel flow pattern but its pressure drop is increased such that the trade off between performance and pressure drop should be considered for selection of flow pattern of fuel cell.

  • PDF

고분자 전해질 연료전지 가스켓 설계 및 성능 평가 (Development and Evaluation of Gasket for Polymer Electrolyte Membrane Fuel Cell Stacks)

  • 서하규;한인수;정지훈;김민성;신현길;허태욱;조성백
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.90.1-90.1
    • /
    • 2010
  • The design and fabrication of a metallic bipolar plate-gasket assembly for polymer electrolyte fuel cells (PEMFCs) is defined. This bipolar plate-gasket assembly was prepared by inserting a previously prepared bipolar plate in the specially designed gasket mold. For this aim, a proprietary fluoro-silicone based rubber was injected directly into the bipolar plate borders. Gaskets obtained like this showed the chemically / physically stable and the good sealibilty in typically operating PEM fuel cell conditions. And also, this bipolar plate-gasket assembly shows lots of advantages with respect to traditional PEMFCs stack assembling systems: useful application to automative stacking due to easy handling, reduced fabrication time, possibility of quality control and failed elements substitution. This bipolar plate-gasket assembly was evaluated in the short fuel cell stack and met the leakage requirement for normal operation both in short-term and in long-term operation. Especially, it was confirmed that this gasket could be applied successfully even in the high pressure FEM fuel cell systems(over 2.0 bar in absolute pressure).

  • PDF

수동급기 직접 메탄올 연료전지의 유로에 따른 성능 평가 (Performance evaluation by flow channel effect for a passive air-breathing Direct Methanol Fuel Cell)

  • 장익황;하승범;차석원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.45-48
    • /
    • 2008
  • This paper presents a passive air-breathing direct methanol fuel cell (DMFC) which has been designed and tested. The single cell is fuelled by methanol vapor that is supplied through flow channel from a methanol reservoir at the anode, and the oxygen is supplied via natural air-breathing at the cathode. The methods for supplying the methanol vapor to the single cell were parallel channel and chamber. This research investigates various methods to identify the effects of using flow channels for providing the methanol vapor at the anode, and the opening ratio between the inlet and outlet ports for the methanol flow at the anode. The best flow channel condition for passive DMFC was a chamber, and the opening ratio was 0.8. Under these conditions, the peak power was 10.2mW/$cm^2$ at room temperature and ambient pressure. The key issues for the Passive DMFCs for using methanol vapor are that sufficient methanol needs to be supplied using a large as possible opening ratio. However, it is shown that the performance of the passive DMFC, which has a channel at the anode,is low due to the low differential pressure and insufficient methanol supply rate.

  • PDF