• Title/Summary/Keyword: Pressure Cell

Search Result 1,800, Processing Time 0.03 seconds

Numerical Simulation of Bullet Impact for Fuel Cell of Rotorcraft (회전익항공기용 연료셀 피탄 수치모사 연구)

  • Kim, Hyun-Gi;Kim, Sung Chan
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.5
    • /
    • pp.405-411
    • /
    • 2012
  • Inside a rotorcraft fuel cell, pipes and components are located for fuel storage and fuel supply into the engine. Utility helicopters, operated in battle fields, fly at lower altitude compared to fixed-wing aircraft and hence are more likely to be exposed to gunfire. Since internal pressure of fluid increases when hit, the effect on LRU due to increase in pressure must taken into account when designing the aircraft for survivability. However, it is costly and time consuming to manufacture a fuel cell for gunfire test, and due to constraints from usage of live ammunition, related data gathered through numerical simulation is needed. In this study, numerical simulation on rotorcraft fuel cell exposed to gunfire was carried out using Autodyn to analyze bullet movement inside the fuel cell after hit, and internal pressure of fluid and equivalent stress on fuel cell assessed.

Operating Conditions of Proton Exchange Membrane Fuel Cell Using Grafoil$^{TM}$ as Bipolar Plates (그라포일 분리판을 이용한 고분자 전해질 연료전지의 운전 조건에 관한 연구)

  • Park, Taehyun;Chang, Ikwhang;Lee, Yoon Ho;Lee, Juhyung;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.85.1-85.1
    • /
    • 2011
  • In this study, Grafoil$^{TM}$ which has comparable electric resistance and chemical stability but is flexible, fragile, and cheap material was adopted as bipolar plates for proton exchange membrane fuel cell(PEMFC) having only one straight line flow channel. Because of its flexibility, pressurizations of cell with various pressures showed different operating characteristics compared to ordinary graphite-used PEMFC. While performances of both cells decreased as these were pressurized, investigation of ohmic and faradaic resistance by electrochemical impedance measurement indicated different tendency of change. Ohmic resistance of graphite-used cell increased with increasing pressure, which is reversed in Grafoil$^{TM}$-used cell. It is speculated that effective chemical reaction area is decreased with increasing pressure in case of graphite-used one, but because of flexible property of Grafoil$^{TM}$, gas diffusion layer in Grafoil$^{TM}$-used cell was well-activated. Different rate of change of faradaic resistances in both cells support this supposition. However, although optimum point of pressurization is found, it is required to investigate other operating conditions because of low performance compared to graphite-used cell.

  • PDF

The Expression of DNA Polymerase-$\beta$ and DNA Damage in Jurkat Cells Exposed to Hydrogen Peroxide under Hyperbaric Pressure

  • Sul, Dong-Geun;Oh, Sang-Nam;Lee, Eun-Il
    • Molecular & Cellular Toxicology
    • /
    • v.4 no.1
    • /
    • pp.66-71
    • /
    • 2008
  • Long term exposure of Jurkat cells to 2 ATA pressure resulted in the inhibition of cell growth. Under a 2 ATA pressure, the morphological changes in the cells were visualized by electron microscopy. The cells exhibited significant inhibitory responses after three passages. However, short-term exposure study was carried out, 2 ATA pressure may have beneficial effects. The Jurkat cells were exposed to $H_2O_2$ (25 and $50{\mu}M$) in order to induce DNA damage, and then incubated under at either normal pressure or 2 ATA for 1 or 2 hours in order to recover the DNA damage. The extent of DNA damage was determined via Comet assay. More recovery from DNA damage was observed at 2 ATA than at normal pressure. The activity of the DNA repair enzymes, DNA polymerase-$\beta$, was also evaluated at both normal pressure and 2 ATA. The activity of DNA polymerase-$\beta$ was observed to have increased significantly at the 2 ATA than at normal pressure. In conclusion, the effects of hyperbaric pressure from 1 ATA to 2 ATA on biochemical systems can be either beneficial or harmful. Long term exposure to hyperbaric pressure clearly inhibited cell proliferation and caused genotoxic effects, but short-term exposure to hyperbaric pressure proved to be beneficial in terms of bolstering the DNA repair system. The results of the present study have clinical therapeutic application, and might prove to be an useful tool in the study of genotoxicity in the future.

Clinical study on the effects of Bleeding Pressure Therapy in patients RBC, Hb and Hct change (습부항이 혈액학적 성상에 미치는 영향에 대한 연구)

  • Song, Bong-Keun;Park, Seug-Won;Kim, Joong-Kil;Kim, Yo-Han;Lee, Si-Woo;Jeong, In-Seok
    • The Journal of Internal Korean Medicine
    • /
    • v.22 no.4
    • /
    • pp.621-625
    • /
    • 2001
  • Objectives: We examined if their hematological status could be changed by blood loss in patients treated with bleeding pressure therapy. Methods: The patients were divided into two groups as follows: The Subject group(B) were 42 cases treated with bleeding pressure therapy. The Control group(N) were 43 cases treated with negative bleeding pressure therapy, We checked CBC & differ cell count of two groups. Results: The means of RBC, Hb count and Hct were slightly decreased after 1 week. but they were recovered after 2 weeks. Conclusions: These results indicate that Bleeding Pressure Therapy don't reduced RBC, Hb count and Hct in Patients.

  • PDF

Validation of Urine Volume Evaluation by Hydraulic Pressure Measurement (압력 측정에 의한 요량 계측의 유용성 분석)

  • Kim, Kyung-Ah;Choi, Sung-Soo;Lee, In-Kwang;Park, Kyung-Soon;Kim, Wun-Jae;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.577-584
    • /
    • 2007
  • Uroflowmetry is non-invasive and easily performed to diagnose benign prostatic hypertrophy(BPH) frequent in aged men. Weight change during urination is usually measured to estimate the urinary flow rate by a load cell, but sensitive to any impacts against the bottom of the container, leading to unnecessary noise generation. Moreover, load cells are relatively expensive raising the production cost. The present study proposed a new technique, measuring hydraulic pressure on the bottom of the urine container to evaluate the urinary volume. Low cost pressure transducer enabled almost perfectly linear relationship between the urine volume and the hydraulic pressure. During both the simulated and human urination experiments, variance of the pressure signal was more than 50% smaller than the weight signal acquired by a load cell, which demonstrated that the impact noise was decreased to a great degree by pressure compared to weight measurement.

Effect of Partial Oxygen Pressure on the Growth and Defense Enzyme Activities of Streptomyces coelicolor in continuous culture system (Streptomyces coelicolor의 연속 배양시 산소 분압에 따른 방어 효소의 활성 변화)

  • 박용두;이계준;노정혜
    • Microbiology and Biotechnology Letters
    • /
    • v.22 no.5
    • /
    • pp.538-543
    • /
    • 1994
  • Effect of partial oxygen pressure on the cell growth and the activities of oxidative defense enzymes were measured in the continuous culture of Streptomyces coelicolor. Both the wild type and the mutant strain resistant to hydrogen peroxide were cultured and the dry cell weight of the two cultures were measured at different oxygen tensions. Growth of the wild type was inhibited by oxygen at above 0.5 vvm. Growth of the hydrogen peroxide resistant mutant was stimulated by pure oxygen at 0.5 vvm but was inhibited by oxygen at 1.0 vvm. Therefore, growth of the hydrogen peroxide resistant mutant was less affected by the deleterious oxidative stress of oxygen. Activities of the several defense enzymes were also measured at different oxygen tensions. Activities of catalase and glucose-6-phosphate dehydrogenase increased significantly as oxygen pressure increased in the wild type culture. In the mutant, however, increase in those enzyme activities was not obvious whereas the uninduced levels of the above enzymes were higher than those of wild type. As judged by Western blotting, the amount of the major catalase increased as the oxygen pressure increased. This indicates that the induction of the catalase activity by oxygen pressure is mostly due to the increase in the expression level for the major catalase.

  • PDF

Effect of Osmotic Pressure of Salts on Growth of Torula sp. and Erythritol Production (염의 삼투압이 Torula sp.의 증식과 Erythritol 생산에 미치는 영향)

  • 김경아;노봉수;김상용;오덕근
    • Microbiology and Biotechnology Letters
    • /
    • v.27 no.2
    • /
    • pp.91-95
    • /
    • 1999
  • To investigate the effect of salts on the production of erythritol by Torula sp., cells were grown on the media containing various concentrations of KCl or NaCl. Cell growth and glucose consumption rates decreased when KCl or NaCl concentration increased from 0.0 to 0.5M. The production of erythritol, however, was maximal at 0.3M aCl. The erythritol concentration of 54.3g/l in the medium containing 0.3M NaCl and 200g/l glucose was obtained after 120h. The production of erythritol decreased in cultures above 0.3M NaCl or 0.4M KCl due to the inhibition of cell growth. To elucidate the effect of salts more quantitatively, KCl and NaCl concentrations were converted to osmotic pressure. As the osmotic pressure increased, the yield of erythritol from glucose increased regardless of the kinds of salts and the yield of erythritol was approximately 49% at the osmolality of 2.4Os/kg. When the osmotic pressure increased to 2.5Os/kg, the specific growth rate of cells decreased but the production rate of erythritol increased. For the effective production of erythritol, osmotic pressure must be adjusted not to inhibit markedly the growth rate of cells and to stimulate the production rate of erythritol by supplementing salt.

  • PDF

Enhancement of Immune Activity of the Extracts from Codonopsis lanceolata by Stepwise Steaming Process and High Pressure Process (증숙 및 초고압 증숙 공정을 통한 더덕의 면역활성 증진)

  • Kim, Nam Young;Chung, Jae Youn;Lee, Hyeon Yong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.22 no.2
    • /
    • pp.134-139
    • /
    • 2014
  • This study was to investigate the improvement of immune activities of the extracts from Codonopsis lanceolata by stepwise steaming process and high pressure process. The phenol contents was $8.742{\mu}g/mg$ which was higher than that from conventional extraction using 70% ethyl alcohol at $80^{\circ}C$ for 24 hours. All of extracts at a concentration of $1.0mg/m{\ell}$ showed relatively low cytotoxicity on human normal kidney cell (HEK293) in range of 16 19%. The immune B and T cell growth was improved by extracts using the steamed and high pressure precess of C. lanceolata up to $180{\times}10^4cells/m{\ell}$ and $96{\times}10^4cells/m{\ell}$, respectively. The extract prepared also greatly increased the secretion of both IL-6 and TNF-${\alpha}$ from the stepwise steamed and high pressure process. This results can conclude that stepwise steamed and high pressure process effectively released active biomaterials which could important role in enhancing immune activity in the body.

Effects of Sensor Errors in Air Cleaner Testing on the Cleaner Performance Estimation (공기청정기 시험기의 센서신호 오차가 공기청정기 성능 평가에 미치는 영향)

  • CHUNHWAN LEE;MINYOUNG KIM;SUMIN LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.1
    • /
    • pp.77-82
    • /
    • 2023
  • The fuel cell in fuel cell electric vehicle utilizes oxygen in the atmosphere, which requires the use of an air cleaner system to minimize the intake of harmful pollutants. To estimate the performance of the air cleaner system, the pressure drop between the filter inlet and outlet is used under the rated air flow condition. In this study, the effect of sensor error in this air cleaner testing is experimentally carried out. It is found that the errors of the temperature sensor does not significantly affect the estimation of pressure drop. However, in the case of the pressure sensor, 5% sensor error results in the error of pressure drop estimation by 3%. Therefore, it is recommended that the measurement accuracy of the pressure sensor mounted in test system should be maintained at less than 5%.