• Title/Summary/Keyword: Pressure Back Flow

Search Result 255, Processing Time 0.032 seconds

Performance Variations of a Small Centrifugal Compressor with Exit Blade Thickness (초소형 원심압축기의 날개 두께 변화에 따른 성능에 관한 실험적 연구)

  • Kang, Shin-Hyoung;Cho, Woon-Je;Yun, Ha-Yong;Lee, Seung-Kap
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.1 s.2
    • /
    • pp.15-21
    • /
    • 1999
  • Some sized centrifugal compressors were designed and their performance measured to investigate the effects of exit blade thickness, width and back swept angle. The impeller of larger blade thickness shows low pressure ratio compared with that of smaller ones. Backswept angle also have a large effect on the efficiency. Measured values of slip factor are quite different from the estimated values of the Wiesner-Busemann model and an increase in the flow late.

  • PDF

Test of The HTS Power Cable Cooling System (초전도케이블 냉각시스템의 냉각특성 시험)

  • 염한길;고득용;김익생;김춘동;김도형
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.281-283
    • /
    • 2003
  • High temperature superconducting power cable requires forced flow cooling. Liquid nitrogen is circulated by a pump and cooled back by cooling system. Typical operating temperature range is expected to be between 65K and 80K. Subcooler heat exchanger uses saturated liquid nitrogen boiling on the shell side to subcool the circulating liquid nitrogen stream that cools the HTS cable. The paper describes performance tests of the cooling system. The test items are heat exchanging performance of subcooler. pressure drop between supply and return lines, heat transfer coefficient inside former, cable cryostat heat leak and simulation of electrical load of HTS cable.

  • PDF

A Study on Design of Nozzle Tip for Airless Spray Coating (에어리스 스프레이 도장용 노즐 팁 설계에 관한 연구)

  • Kim, Dong-Keon;Kim, Soon-Kyung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.6
    • /
    • pp.183-188
    • /
    • 2012
  • This study was carried out to design the spray nozzle tip for airless spray coating. Airless spray coating is the process of coating an object with a liquid spray of paint or other fluid. The nozzle tip controls the fluid flow rate and creates back pressure in the system. The nozzle tip also defines the spray pattern by the size and shape of the orifice. The spray pattern of nozzle tip was investigated numerically using ANSYS CFX ver. 14.0. It was observed that performance result of designed nozzle tip was correspond well, compared with that of GARCO nozzle tip.

Analysis of Pressure Rise in Gas Circuit Breakers Considering Nozzle Ablation (노즐용삭을 고려한 초고압 가스차단기의 압력상승 해석)

  • Kim H.K.;Song K.D.;Park K.Y.;Bae C.Y.;Jung H.K.;Park S.K.;Lee B.H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1100-1102
    • /
    • 2004
  • 열팽창 방식의 가스차단기는 아크 에너지 자체를 이용하여 압력상승을 얻고, 상승된 압력을 이용하여 전류 영점 부근에서 아크 방향으로의 유동을 형성하여 아크를 소호한다. 대전류 구간에서 노즐 폐색현상이 일어나면 노즐 용삭이 크게 일어나며 용삭된 노즐 물질은 팽창실의 압력과 온도를 상승시키게 된다. 따라서 차단 특성해석을 위해서는 노즐 용삭에 의한 압력 상승해석이 필요하다. 본 논문에서는 아크에너지에 따른 노즐 용삭비를 이용하여 용삭되는 노즐량을 계산하고, 이로 인한 back flow현상을 고려한 해석 방법을 제안한다. 개발된 프로그램을 제작한 차단부 모델에 적용한 결과, 열팽창실의 압력상승치는 시험결과와 잘 일치함을 확인하였다.

  • PDF

Investigation of influence of linear diffuser in the ventilation of operating rooms

  • Keshtkar, Mohammad Mehdi;Nafteh, Maryam
    • Advances in Energy Research
    • /
    • v.4 no.3
    • /
    • pp.239-253
    • /
    • 2016
  • Air quality in hospitals has always concerned hospitals' health officials due to its dangerous particles and gases. Because of the importance of air conditioning in the operating room, a system must be embedded in operating rooms to direct the contaminated air outside, and inject fresh filtered air from outside back into the room. In this study, laminar flow air conditioning system is implemented in the operating room by slot linear diffusers and with the help of air curtain. For this, stimulation Computational Fluid Dynamic (CFD) was used due to its efficiency. The aim of the present study was to find a proper solution to overcome the unfavorable factors, namely, contamination, humidity, and also temperature, velocity and pressure inside the room. These factors were implemented with different values and then stimulated through FLUENT software program. Results showed that the aforementioned factors can be overcome using air curtain and slot linear diffusers.

Development of Chestnut Harvesters for Small Farms (소농을 위한 밤 수확기의 개발)

  • Kang, Whoa-Seug;Guyer, Daniel
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.384-389
    • /
    • 2008
  • Three prototype chestnut harvesters were constructed and evaluated their chestnut collection ability and field efficiency. Air-lock paddle system successfully picked up all loose material, and pick up efficiency was about 56 kg/h. Power required to operate this system was evaluated to be 8.7 kW with an air flow rate of $32.6\;m^3/min$. A radial blade type blower with 0.41 m impeller diameter was considered to be a minimum size for this system. For the auger system, air was sucked into the cylinder as the hinged flat cover began to be opened by the material pushed by the auger, and the empty burrs flew back to the container through the space between auger flights and collected in the bottom of the container. It was considered to add a device to prevent air from flowing back or to use the back flowing air for separation of burrs and nuts inside the container. The venturi system could not pick up chestnuts, as they only carried part way up to the suction hose. Consideration was given to an idea that the venturi could be used as a cleaning and separation mechanism for containers filled with both empty burrs and good nuts. A minimum vacuum of 129 mm wg was required to pick up chestnuts, and the corresponding inlet air velocity was 19.3 m/s. 104 mm of vacuum, which was about 81 % of that required for nuts, was enough to pick up burrs with nuts inside. Also, empty burrs with higher moisture content recorded the same pressure as for the burrs with nuts.

Effect of Operating Conditions and Recovery of Water Back-washing in Spiral Wound Microfiltration Module Manufactured with PVDF Nanofibers for Water Treatment (수처리용 PVDF 나노섬유 나권형 정밀여과 모듈에서 운전조건의 영향과 물 역세척 회복)

  • Kyung, Kyu Myung;Park, Jin Yong
    • Membrane Journal
    • /
    • v.25 no.2
    • /
    • pp.180-190
    • /
    • 2015
  • PVDF (polyvinylidene fluoride) nanofiber has the advantages such as excellent strength, chemical resistance, nontoxic, non-combustibility. Flat membranes with 0.3 and $0.4{\mu}m$ pore size respectively, were manufactured by PVDF nanofiber, and then each spiral wound module was prepared with them. A woven paper was not included in preparing the module with $0.3{\mu}m$ pore size; however, it was included the module with $0.4{\mu}m$ pore size. The permeate fluxes and rejection rates of the two modules were compared using pure water and simulation solution including kaolin and humic acid. The recovery rate and filtration resistance were calculated after water back-washing. In addition, the effect of flow rate and trans-membrane pressure on treatment efficiency and filtration resistance were investigated for the spiral wound module with $0.4{\mu}m$ pore size.

Experimental Study on Features of Air Egress Velocity in Vestibule Pressurization System (특별피난계단 부속실 제연설비의 방연풍속 기류특성에 관한 실험적 연구)

  • Ryu, Sung-Ho;Lee, Su-Kyung;Hong, Dae-Hwa;Yoon, Myong-O;Choi, Keum-Ran;Park, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.79-86
    • /
    • 2010
  • In this study, we confirmed the fact that air egress velocity of pressure differential system which is installed in vestibule of smokeproof stairway in domestic high-rise building becomes back-flow into the vestibule not into the livingroom when the doors open to escape in case of fire by actual measurement. It concerned that fire smoke inflow into the vestibule of smokeproof stairway. so, reflux symptoms were developing the condition does not occur by creating an area of $2m^2$ and a model. if it‘s area is less, airflow in upper area was severely reflux. in the case upward 45 gradient of supply damper’s angle of blade, The results that reflux symptoms include upper door but bottom has some reflux. also vestibule of smokeproof stairway‘s area of $4m^2$ in the living room door in the direction of the flow distributon was normal. if a vestibule of smokeproof stairway is smaller, it designed to be performance-based design should be.

Statistical Qualitative Analysis on Chemical Mechanical Polishing Process and Equipment Characterization

  • Hong, Sang-Jeen;Hwang, Jong-Ha;Seo, Dong-Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.3
    • /
    • pp.115-118
    • /
    • 2011
  • Process characterization of the chemical mechanical polishing (CMP) process for undensified phosphosilicate glass (PSG) film is reported using design of experiments (DOE). DOE has been addressed to experimenters to understand the relationship between input variables and responses of interest in a simple and efficient way. It is typically beneficial for determining the adequate size of experiments with multiple process variables and making statistical inferences for the responses of interests. Equipment controllable parameters to operate the machine include the down force (DF) of the wafer carrier, pressure on the backside of the wafer, table and spindle speed (SS), slurry flow rate, and pad condition. None of them is independent; thus, the interaction between parameters also needs to be indicated to improve process characterization in CMP. In this paper, we have selected the five controllable equipment parameters, such as DF, back pressure (BP), table speed (TS), SS, and slurry flow (SF), most process engineers recommend to characterize the CMP process with respect to material removal rate (RR) and film uniformity as a percentage. The polished material is undensified PSG. PSG is widely used for the plananization in multi-layered metal interconnects. We identify the main effect of DF, BP, and TS on both RR and film uniformity, as expected, by the statistical modeling and analysis on the metrology data acquired from a series of $2^{5-1}$ fractional factorial design with two center points. This revealed the film uniformity of the polished PSG film contains two and three-way interactions. Therefore, one can easily infer that the process control based on better understanding of the process is the key to success in semiconductor manufacturing, typically when the wafer size reaches 300 mm and is continuously scheduled to expand up to 450 mm in or little after 2012.

Rocket Plume Analysis with DSMC Method (DSMC 방법을 이용한 로켓 플룸의 해석)

  • Jeon, Woojin;Baek, Seungwook;Park, Jaehyun;Ha, Dongsung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.5
    • /
    • pp.54-61
    • /
    • 2014
  • In this study, a plume exhausted from rocket nozzle is investigated by using an unstructured 2-dimensional axisymmetirc DSMC code at various altitude. The small back-pressure to total-pressure ratio($P_b/P_o$) and large $P_b/P_o$ represent low and high altitude condition, respectively. At low altitude, the plume shows a typical complicated structure (e.g. Mach disk) of underexpanded jet while the high altitude plume experiences plain expansion. The various features of exhaust plume is discussed including density, translational/rotational temperature, Mach number and Knudsen number. The results shows that even at 20 km altitude where the freestream Knudsen number is small as $1.5{\times}10^{-5}$, the transitional and rarefied flow regimes can occur locally within the plume. It confirms the necessity of DSMC computation at low altitude.