• Title/Summary/Keyword: Precast concrete deck

Search Result 92, Processing Time 0.026 seconds

Removable shear connector for steel-concrete composite bridges

  • Suwaed, Ahmed S.H.;Karavasilis, Theodore L.
    • Steel and Composite Structures
    • /
    • v.29 no.1
    • /
    • pp.107-123
    • /
    • 2018
  • The conception and experimental assessment of a removable friction-based shear connector (FBSC) for precast steel-concrete composite bridges is presented. The FBSC uses pre-tensioned high-strength steel bolts that pass through countersunk holes drilled on the top flange of the steel beam. Pre-tensioning of the bolts provides the FBSC with significant frictional resistance that essentially prevents relative slip displacement of the concrete slab with respect to the steel beam under service loading. The countersunk holes are grouted to prevent sudden slip of the FBSC when friction resistance is exceeded. Moreover, the FBSC promotes accelerated bridge construction by fully exploiting prefabrication, does not raise issues relevant to precast construction tolerances, and allows rapid bridge disassembly to drastically reduce the time needed to replace any deteriorating structural component (e.g., the bridge deck). A series of 11 push-out tests highlight why the novel structural details of the FBSC result in superior shear load-slip displacement behavior compared to welded shear studs. The paper also quantifies the effects of bolt diameter and bolt preload and presents a design equation to predict the shear resistance of the FBSC.

Requirement Analysis of the System Form for the Bridge Slab (교량 상판(바닥판) 콘크리트 타설용 시스템 거푸집 개발을 위한 요구조건 분석)

  • Kim, Taekoo;Lim, Jeeyoung;Kim, Sunkuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.195-196
    • /
    • 2014
  • Unlike general construction works, bridge construction is mostly done in a high place. The conventional deck form of bridge is installed between precast concrete girders using sleepers, bridging joints and plywoods, and after concrete is poured to the deck, the form materials are removed at high altitudes. When removing the form, it may be dropped on ground, damaging the materials and resulting in economic loss. In addition, safety accidents are likely as the works are performed in a high place, and as the manpower increases, the cost increases. Also, it is difficult to install and remove temporary equipment. Therefore, it is required to develop a system form that allows easier and quicker installation and removal by unskilled workers and ensures safety of workers. In this regard, the study is intended to analyze requirements for the system form for pouring concrete to bridge decks, which can be easily installed and removed. The study result will be used as basic information for development of the system form for pouring concrete to bridge decks.

  • PDF

Applicability Evaluation of PSC-U Type Girder and Precast Deck to the Vertical Curves in Urban Maglev Train Route (도심형 자기부상열차 선로 종곡선 구간에서의 PSC-U 형 거더와 프리캐스트 바닥판 적용성 평가)

  • Jin, Byeong-Moo;Kim, In-Gyu;Kim, Young-Jin;Lee, Yun-Seok;Ma, Hyang-Wook;Oh, Hyun-Chul
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.24-30
    • /
    • 2008
  • One of the characteristics of the Maglev Train is the prominent capability of upgoing. Maglev train with the aim of longitudinal slope 7/100 is under development by the Center for Urban Maglev Program in Korea. To realize these slope, vertical curves must be inserted before and after the slope. The inserted curve has the radius of 3,000m generally. The insertion of these vertical curve results in the additional differences between the girder upper face and the guide rail, and the alignments are controlled by cast in place concrete at present. In this study, for longitudinal curved route with longitudinal slope 6/100, the applicability of PSC-U type girder and precast deck was evaluated for the span length 25m, 30m and vertical curve radii with 3,000m and 1,500m with respect to longitudinal slope 6/100.

  • PDF

A Study on Bond Properties of Joint Grouting Materials for Precast Concrete Bridge Decks (프리캐스트 콘크리트 교량바닥판 이음부 채움재의 부착특성연구)

  • 김영진;정철헌;심창수
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.1
    • /
    • pp.153-159
    • /
    • 1998
  • 최근 교통량의 증가에 의해 직접 하중을 부담하는 교량바닥판의 손상이 심각한문제로 부각되고 있다. 더욱이 차량하중의 증가는 바닥판손상을 더욱 가속화시키고 있는 실정이다. 바닥판의 손상이 심한 경우에는 교체 또는 성능개선공사를 시행하게 되는데, 이때 기존의 현장타설바닥판이 갖는 단점을 보완할 수 있는 프리캐스트 콘크리트 바닥판은 공기단축, 품질확보 등의 측면에서 매우 효과적인 대체공법이 될 수 있다. 프리캐스트 콘크리트 바닥판은 기존의 현장타설바닥판과달리 바닥판간에 이음부를 갖는 구조적 특징이 있으며, 다양한응력상태에 있는 바닥판중에 존재하는 비연속부인 이음부와 콘크리트 부재사이의 원활한 하중전달을 위해 부착강도는 매우 중요하다. 따라서 본 연구에서는 이음부의 부착강도를 함리적으로 평가할 수 있는 새로운 실험방법을 제안하고 이를 이용하여 휨, 직접인장 및 전단실험을 수행하였다. 또한 구성재료에 대한 압축, 휨인장 및 할렬인장강도 특성도 평가하였 다. 부착 및 강도특성에 관한 실험결과, 제안된 실험방법을 이용하면 실제에 근접한 부착강도를 평가할 수 있으며 국내에서 사용되는 충전재료중 무수축모르터가 프리캐스트 콘크리트 바닥판간 이음부의 채움재로서의 기본요건을 만족하고 있는 것을 알 수 있었다.

Mechanical behavior of steel-concrete composite decks with perfobond shear connectors

  • Allahyari, Hamed;Dehestani, Mehdi;Beygi, Morteza H.A.;Neya, Bahram Navayi;Rahmani, Ebrahim
    • Steel and Composite Structures
    • /
    • v.17 no.3
    • /
    • pp.339-358
    • /
    • 2014
  • Exodermic deck systems are new composite steel grid deck systems which have been used in various projects during the past decade. One of the eminent features of this system is considerable reduction in the structure weight compared to the ordinary reinforced concrete decks and also reduction in construction time by using precast Exodermic decks. In this study, dynamic properties of the Exodermic deck bridges with alternative perfobond shear connectors are investigated experimentally. In order to evaluate the dynamic properties of the decks, peak picking and Nyquist circle fit methods are employed. Frequencies obtained experimentally are in good agreement with the results of the finite-element solution, and the experimental results show that the first mode is the most effective mode among the obtained modes. The first four modes are the rigid translational motion modes, and the next two modes seem to be rigid rotational motion modes around a horizontal axis. From the 7th mode onwards, modes are flexible. The range of damping ratios is about 0.5%. Furthermore, the static behavior of the Exodermic decks under a static load applied at the center of the decks was investigated. Failure of the decks under positive bending was punching-shear. The bending strength of the decks under negative bending was about 50 percent of their strength under positive bending. In addition, the weight of an Exodermic deck is about 40% of that of an equivalent reinforced concrete slab.

Evaluation of Static Strength of Group Stud Shear Connection in Precast Concrete Deck Bridges (프리캐스트 콘크리트 바닥판 교량의 그룹 스터드 전단연결부 강도평가)

  • Shim, Chang Su;Jeon, Seung Min;Kim, Dong Wook
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.333-345
    • /
    • 2008
  • concrete deck bridges are increasingly aplied to twin- girder bridges and open-stel box girder bridges.One of the most dificult isues in the design of shear conect ors is the mater of achieving ful composite action. Many connectors in smal area require a significant section los of precast decks resulting in difficult reinforcement details. In this closer spacing than the required minimum spacing in the design codes was evaluated through static tests. Test results s howed that the ultimate strength decreased as the conector spacing was reduced. The strength enhancement was observed due to aditional reinforcement for precast slabs or for shear pockets. Thus, the design of group stud shear connection needs to anticipate failure modes and the conector failure should be induced. Based on the test results, an empirical equation consi dering stud spacing was proposed to evaluate the ultimate strength of group stud shear conection. Fatigue tests showed n o reduction in fatigue life of the group stud shear conection in the range of this research. Details of the precast decks wer e enhanced using the findings of the study.

Evaluation of the Bending Performance of a Modified Steel Grid Composite Deck Joint (격자형 강합성 바닥판의 수정된 이음부에 대한 휨성능 평가)

  • Shin, Hyun-Seop;Park, Ki-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.38-47
    • /
    • 2013
  • For the joint connection of the precast steel grid composite decks, the prefabricated joint which is composed of concrete shear key and high-tension bolts was already proposed. In this study, for the purpose of increasing the bending stiffness and bending strength of the proposed prefabricated joint section details of the proposed joint are modified, and through experimental tests the bending performance, such as stiffness and strength of a modified joint, is compared with those of the proposed joint. Test and analysis results show that the shear cracks in the concrete shear key are clearly reduced by the strengthening of the shear key using shear studs and additional rebars. According to analysis results of the moment-curvature relationship, bending stiffness of the modified joint is about 47% greater than the stiffness of the proposed joint. Furthermore, the modified joint has about 32% greater bending strength than the proposed joint. Compared to specimens without the joint the modified joint has same or slightly higher bending strength, but about 37% lower bending stiffness.

Design of longitudinal prestress of precast decks in twin-girder continuous composite bridges (2거더 연속강합성 교량의 프리캐스트 바닥판 종방향 프리스트레스 설계)

  • Shim, Chang Su;Kim, Hyun Ho;Ha, Tae Yul;Jeon, Seung Min
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.633-642
    • /
    • 2006
  • Serviceability design is required to control the cracking at the joint of precast decks with longitudinal prestress in continuous composite bridges. Details of twin-girder bridges are especially complex not only due to their main reinforcements and transverse prestresses for the design of long-span concrete slabs, but also due to the shear pockets for obtaining the composite action. This paper suggests the design guidelines for the magnitude of the effective prestress and for the selection of filling materials and their requirements that would allow for the use of precast decks for twin-girder continuous composite bridges. The necessary initial prestress was also evaluated through long-term behavior analysis. From the analysis, existing design examples were revised and their effectiveness was estimated. When a filling material with a bonding strength higher than the requirement is used in the region of a high negative moment, a uniform configuration of the longitudinal prestressing steels along thewhole span length of continuous composite bridges can be achieved, which would result in the simplification of the details and the reduction of the construction costs.

Influence of Cracks in Precast Concrete Deck on the Flexural Strength of Composite Half PC Slab (하프PC 슬래브에 발생한 균열이 합성 슬래브의 휨 내력에 미치는 영향에 관한 실험적 연구)

  • Seo, Tae-Seok;Lee, Moon-Sung;Choi, Chang-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.199-205
    • /
    • 2009
  • Recently, as the concern for the development of a construction method for an environmental protection and for tall building is increasing, the use of the half precast concrete(PC) slab that has the solution of environmental problems and the advantage such as reduction of construction period is being demanded. However, there is shortcoming that the crack can occur easily while constructing, and these cracks can have a bad influence upon the structural performance of PC composite slab. However, there is little studies on the influence of these cracks on the structural performance of composite PC slab. In this study, the specimen caused the crack before pouring topping concrete in the half PC slab and the PC composite slab without the cracks were produced to investigate the structural performance of PC composite slab with crack.

Structural Performance and Usability of Void Slab Established in T-deck Plate (T형 데크 플레이트 중공형 슬래브의 구조성능 및 사용성능)

  • Hong, Eun-Ae;Chung, Lan;Paik, In-Kwan;Yun, Sung-Ho;Cho, Seung-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.677-684
    • /
    • 2012
  • In recent years, extension of life span of buildings is becoming an important issue in our society. To improve the life span of buildings, rhamen structure construction and long-spanned structures are advantageous. And in order to achieve this goal, structural elements of buildings must be light and slender. As an alternative method, general porous slabs are used frequently domestically and internationally. But the study on the porous slabs using T-deck plate and assembly of light weight precast construction is insufficient at present. In this study, flexural and fatigue tests were performed on six specimens to verify structural performance and serviceability. The main parameters of the specimens were light weight and T-deck plate construction possibility as well as slab thickness. The test results indicated that the strength of porous slabs using T-deck plate and assembly of light weight were much better than general RC slabs and porous slabs without T-deck plate. And stiffness was much better than that of other tested slabs.