• 제목/요약/키워드: Precast Concrete slab

검색결과 160건 처리시간 0.022초

RC 라멘조에 SMART Frame 적용 시 효용성 분석 (Performance Analysis of SMART Frame Applied to RC Column-Beam Structures)

  • 조원현;임채연;장덕배;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.168-169
    • /
    • 2015
  • SMART Frame is a composite precast concrete structure system to deliver the advantages of both steel frame and reinforced concrete. Many studies have established to date that SMART Frame is more advantageous than conventional frame-type structure in terms of structural stability, constructability, economic viability as well as reduction of construction schedule. However, such studies have focused primarily on wall-type or flat slab-type apartment housing structures, failing to include Rahmen structures in their scope. Accordingly, this study aims to analyze the benefits of potential application of SMART Frame to RC Rahmen structures. As the structural stability and constructability of SMART Frame is already proven, this study reviews its benefits from the perspective of cost reduction. Conclusion of this study will be used subsequently in predicting the benefits of SMART Frame when it is adapted to RC Rahmen structures.

  • PDF

Precast PSC-Segmental I형 거더의 휨거동에 관한 연구 (Flexural Behavior of Precast PSC Segmental I Girder)

  • 홍성남;김광수;박선규
    • 대한토목학회논문집
    • /
    • 제26권3A호
    • /
    • pp.421-428
    • /
    • 2006
  • 본 연구는 일체형과 분절형 거더의 거동차이 최소화 및 PSI(Precast PSC-Segmental I Grider)거더의 역학적 거동 특성을 실험적으로 검증하기 위하여 실물 크기의 거더를 일체형(CG)실험체 1본, 분절형(SGT1, SGT2, SGT3)실험체 3본을 제작하여 실험을 수행하였다. 일체형(CG)실험체는 단 경간으로 25 m의 길이로 제작하였고, 분절형 실험체는 각 세그멘트를 5 m 길이로 제작하고 1차 긴장력을 도입하여 하나의 거더로 일체화 시킨 후, 슬래브를 타설한 다음 2차 긴장력을 도입하는 방법으로 제작하였다. 실험결과 모멘트는 실험값과 이론값의 오차가 매우 작거나 실험값이 이론값에 비해 약간 더 큰 것으로 나타나 PSI거더의 이론이 신뢰성이 있는 것으로 나타났다.

철근콘크리트 아치 데크의 정적 휨 거동 (Flexural Behavior of RC Arch Deck Subjected to Static Loading)

  • 엄기하;양달훈;김성재;김장호
    • 콘크리트학회논문집
    • /
    • 제29권4호
    • /
    • pp.371-378
    • /
    • 2017
  • 본 연구에서는 철근콘크리트 아치 데크의 정적재하실험을 통해 휨 거동을 평가하였다. 휨 실험은 길이 2.5 m, 폭 1.2 m, 중심단면 두께 100 mm, 단부단면 두께 160 mm의 실제 크기 프리캐스트 철근콘크리트 아치 데크의 정적재하 실험을 실시하였다. 실험결과는 극한설계강도에 비하여 약 1.74배 높은 하중을 견디는 것으로 관찰되었다. 반면, 실험체에는 구간에 따라 각각 다른 거동이 관찰되었다. 이러한 거동은 아치 데크와 이를 지지하는 반력대 사이에 일체거동이 이뤄지지 않은 이유로 인한 것으로 판단되었다. 그러므로 추후 연구에서는 반력대를 제외한 아치 데크의 정적재하 실험을 통해 정밀한 거동을 확인해야 할 것으로 사료된다. 실험결과를 종합하여 보면, 철근콘크리트 아치 데크는 일반형태의 바닥판에 비하여 우수한 구조적 이점을 통해 설계기준보다 높은 구조성능을 나타내었다. 이를 통해, 향후에는 장지간 바닥판으로써의 활용이 가능할 것으로 사료된다.

경화촉진제를 사용한 내화재 일체형 프리캐스트 슬래브의 화재저항성능 평가 (Fire Resistance Assessment of Precast Duct Slab with Fireproof using Hardening Accelerator)

  • 최순욱;강태호;이철호;김세권;김태균;장수호
    • 터널과지하공간
    • /
    • 제32권6호
    • /
    • pp.363-372
    • /
    • 2022
  • 프리캐스트 콘크리트는 제작조건을 최적화하고 유사하게 함으로써 시공품질과 시공속도를 높일 수 있는 효과적인 방법이다. 본 연구에서는 좀 더 효과적으로 내화재 일체형 프리캐스트 슬래브 제품을 제작하기 위해, 경화촉진제를 사용하여 양생속도를 증가시키는 방법을 사용할 경우 내화재의 화재저항성능이 유지되는지를 파악하고자 하였다. 경화촉진제 포함 여부에 따라 구분된 시험체에 대해 화재저항성능시험을 수행한 결과, 경화촉진제를 사용한 시험체에서 시험체 내부의 온도증가가 높게 나타났으며, 화재가열면에서 내화재의 단면손실이 국부적으로 발생하였다. 결론적으로 본 연구에서 사용한 조건과 같이 경화촉진제를 사용하여 재령 3일 강도를 재령 1일에 발현시킨 경우의 내화재는 RWS화재시나리오 하에서 충분한 화재저항성능을 보장하지 못하는 것으로 판단된다.

Parametric study on the structural behaviour of composite slim floors with hollow-core slabs

  • Spavier, Patricia T.S.;Kataoka, Marcela N.;El Debs, Ana Lucia H.C.
    • Computers and Concrete
    • /
    • 제28권5호
    • /
    • pp.497-506
    • /
    • 2021
  • Steel-concrete composite structures and precast concrete elements have a common prefabrication process and allow fast construction. The use of hollow-core slabs associated with composite floors can be advantageous. However, there are few studies on the subject, impeding the application of such systems. In this paper, a numerical model representing the considered system using the FE (finite element)-based software DIANA is developed. The results of an experimental test were also presented in Souza (2016) and were used to validate the model. Comparisons between the numerical and test results were performed in terms of the load versus displacement, load versus slip, and load versus strain curves, showing satisfactory agreement. In addition, a wide parametric study was performed, evaluating the influence of several parameters on the behaviour of the composite system: The strength of the steel beam, thickness of the web, thickness and width of the bottom flange of the steel beam and concrete cover thickness on top of the beam. The results indicated a great influence of the steel strength and the thickness of the bottom flange of the steel beam on the capacity of the composite floor. The remaining parameters had limited influences on the results.

Web-shear capacity of prestressed hollow-core slab unit with consideration on the minimum shear reinforcement requirement

  • Lee, Deuck Hang;Park, Min-Kook;Oh, Jae-Yuel;Kim, Kang Su;Im, Ju-Hyeuk;Seo, Soo-Yeon
    • Computers and Concrete
    • /
    • 제14권3호
    • /
    • pp.211-231
    • /
    • 2014
  • Prestressed hollow-core slabs (HCS) are widely used for modern lightweight precast floor structures because they are cost-efficient by reducing materials, and have excellent flexural strength and stiffness by using prestressing tendons, compared to reinforced concrete (RC) floor system. According to the recently revised ACI318-08, the web-shear capacity of HCS members exceeding 315 mm in depth without the minimum shear reinforcement should be reduced by half. It is, however, difficult to provide shear reinforcement in HCS members produced by the extrusion method due to their unique concrete casting methods, and thus, their shear design is significantly affected by the minimum shear reinforcement provision in ACI318-08. In this study, a large number of shear test data on HCS members has been collected and analyzed to examine their web-shear capacity with consideration on the minimum shear reinforcement requirement in ACI318-08. The analysis results indicates that the minimum shear reinforcement requirement for deep HCS members are too severe, and that the web-shear strength equation in ACI318-08 does not provide good estimation of shear strengths for HCS members. Thus, in this paper, a rational web-shear strength equation for HCS members was derived in a simple manner, which provides a consistent margin of safety on shear strength for the HCS members up to 500 mm deep. More shear test data would be required to apply the proposed shear strength equation for the HCS members over 500 mm in depth though.

대직경 스터드 전단연결재의 정적거동 (Static Behavior of Large Stud Shear Connectors)

  • 이필구;심창수;윤태양
    • 한국강구조학회 논문집
    • /
    • 제15권6호통권67호
    • /
    • pp.611-620
    • /
    • 2003
  • 강합성교량에서 19mm 또는 22mm 직경을 갖는 전단연결재가 일반적으로 사용되고 있다. 강교 상세의 단순화와 향후 바닥판 제거의 용이성 및 프리캐스트 바닥판 전단포켓의 효율적인 배치를 위해서는 대직경 스터드 전단연결재가 필요하다. 현재의 전단연결재 설계범위를 넘어서는 대직경 스터드 전단연결재에 대한 push-out 실험을 통해서 정적거동에 관한 항목들을 검토하고 기존 설계식과의 비교를 수행하였다. 25, 27, 30mm 직경의 스터드에 대한 전단실험을 통해서 탄성영역에서의 전단강성을 평가하고 세 개의 직선으로 구성된 하중-상대변위 곡선을 제안하였다. 파괴시의 극한상대변위를 평가하고 극한강도를 유로코드-4의 설계식과 비교하여 설계의 안전율을 평가하였다. 또한 30mm 스터드의 경우는 용접과 콘크리트 지압능력의 개선이 필요한 것으로 나타났다.

PC부재의 접합부 거푸집의 개선방안 연구 -공동주택을 중심으로- (Improvement Plan for Connecting Form of PC Member -Focused on Apartment Buildings-)

  • 김선형;최재휘;김선국;이동훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 1부
    • /
    • pp.9-12
    • /
    • 2010
  • Conventional apartment building projects have favored wall slab structure for the ease of construction and economic viability. However, wall slab structure, consisting of bearing walls, makes remodeling a difficult challenge. In addition, as the amendment to the Building Act in November, 2005 incentivized easy-to-remodel Rahmen structure design for apartment building in terms of floor area ratio and the number of stories, were are seeing more use of PC construct method in apartment building projects gradually. However, PC construction method requires complex connections between beams and columns, making it difficult to install and remove formwork. Furthermore, it is not possible to reuse forms after removal, generating lots of construction wastes, and it is necessary to install new forms again when the size of connection changes in line with modification of column cross-section. Researchers in Korea and elsewhere in the world have focused on structural performance of connection in PC construction method, with little attention to alternative approaches to improving connection forms for PC construction method. Accordingly, this research aims to study an approach to improving connection forms for PC construction method.

  • PDF

A system of multiple controllers for attenuating the dynamic response of multimode floor structures to human walking

  • Battista, Ronaldo C.;Varela, Wendell D.
    • Smart Structures and Systems
    • /
    • 제23권5호
    • /
    • pp.467-478
    • /
    • 2019
  • Composite floor structures formed by continuous slab panels may be susceptible to excessive vibrations, even when properly designed in terms of ultimate limit state criteria. This is due to the inherent vibration characteristics of continuous floor slabs composed by precast orthotropic reinforced concrete panels supported by steel beams. These floor structures display close spaced multimode vibration frequencies and this dynamic characteristic results in a non-trivial vibration problem. Structural stiffening and/or insertion of struts between floors are the usual tentative solution applied to existing vibrating floor structures. Such structural alterations are in general expensive and unsuitable. In this paper, this vibration problem is analyzed on the basis of results obtained from experimental measurements in typical composite floors and their theoretical counterpart obtained with computational modeling simulations. A passive control system composed by multiple synchronized dynamic attenuators (MSDA) was designed and installed in these floor structures and its efficiency was evaluated both experimentally and through numerical simulations. The results obtained from experimental tests of the continuous slab panels under human walking dynamic action proved the effectiveness of this control system in reducing vibrations amplitudes.

프리캐스트 합성 중공바닥판의 교축방향 이음부에 대한 실험 (Experiments on Longitudinal Joints of Precast Composite Hollow Slabs)

  • 심창수;정영수;김대호;민진;김병석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.14-17
    • /
    • 2004
  • A prefabricated composite hollow slab with perforated I-beams was suggested for the replacement of deteriorated concrete decks or the construction of new composite bridges with long-span slabs. Composite slabs with embedded I-beams have considerably higher stiffness and strength. For the application of prefabricated composite slabs to bridges, joints between slabs should satisfy the requirements of the ultimate limit state and the serviceability limit state. In this paper, three types of the detail for loop joints were selected and their structural performance in terms of strength and crack control was investigated through static tests on continuous composite slabs. A main parameter was the detail of the joint, such as an ordinary loop joint and loop joint with additional reinforcements. Even though there was no connection of the steel beams at the joints, the loop joints showed good performance in ultimate strength. In terms of crack control, the loop joint with additional reinforcements showed better performance. In ultimate limit state, the continuous composite slabs showed good moment redistribution and ductility.

  • PDF