• Title/Summary/Keyword: Pre-ozonation

Search Result 25, Processing Time 0.026 seconds

Pre-Coagulation and Pre-Ozonation for Ozone Resisting Microfiltration Membrane Filtration System of a High Humic Contained Surface Water (고농도 휴믹성분이 포함된 강 원수에서 응집-침전 및 오존 공정을 전처리로 적용한 오존 내성막 pilot plant에서의 운전성 및 투과수 수질변화에 관한 연구)

  • Lee, Sanghyup;Yoshimasa, Watanabe;Lee, Seockheun;Ahn, Kyuhong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.598-607
    • /
    • 2004
  • In this study, the effects of two pre-treatment processes were observed prior to membrane filtration: pre-coagulation and pre-ozonation. To compare the effect of two above-mentioned pre-treatments, we adopted the four schemes: first one is direct membrane filtration of river surface water, second one is membrane filtration after pre-coagulation, third one is membrane filtration after pre-ozonation and fourth one is membrane filtration after pre-coagulation and pre-ozonation. There are two exceptional characteristics in applied processes. One is the usage of the MF membrane which has high ozone resisting characteristic. Therefore, ozone resides in membrane module during filtration. The other is adoption of Jet Mixed Separator (JMS) as coagulation-sedimentation process. The change in transmembrane pressure and permeate water quality were also examined. As a result, considering the filtration performance efficiency and permeate water quality, the process composed of filtration with combination of both pre-coagulation and pre-ozonation was proved most effective. The improved efficiency was due to the reduction of loading rate of fouling inducing materials to membrane module by coagulation process as well as variable reactions, such as degradation, particle destabilization and coagulation, occurred by residual ozone in membrane module. The additional effect of pre-coagulation before pre-ozonation is suppression of AOC, one of the by-products induced by ozonation. Therefore, combination of pre-coagulation and pre-ozonation is the effective process to overcome the major de-merit of ozonation i.e. by-products formation.

A Study on the Ozonation of Dyeing Wastewaters (오존에 의한 폐수처리에 관한 연구 -염색폐수의 COD처리 및 탈색에 관하여-)

  • 김덕묵;강부부
    • Journal of the Korean Professional Engineers Association
    • /
    • v.15 no.2
    • /
    • pp.24-31
    • /
    • 1982
  • This study concerns with the reduction of the COD and deceleration of dyeing wastewater from DAEGU city area by ozonation. The COD reduction by ozonation follows near linear relationships versus ozonation time, temperature and concentration. The color in dyeing wastewater and of dyes can he strikingly reduced as the water is quasi colorless after ozone treatment. COD reduction rate of wastewater was found not to be dependented on pH, however, high temperature gave better results, although economically not feasible. The ozonation of dyeing wastewater can give good results when dyes, scouring agent and sticking agents were pre-separated.

  • PDF

Evaluation of Advanced Water Treatment Operation

  • Kim, Seung-Hyun
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.54-64
    • /
    • 2002
  • This study evaluated advanced water treatment (AWT) system in Korea. There are currently 16 plants operating with AWT. However, no attempt has been made to evaluate AWT system. This study selected one water treatment plant with AWT (pre-ozonation + BAC). Using the operation data from 1995 to 2001 and pilot study results, the post-evaluation of the AWT system has been conducted. The study found that AWT improved water qualities of organic, ammonia, and turbidity, as expected. However, the extent of the improvement was generally short of the pilot study expectations. Pre-ozonation failed to decrease coagulant consumption. The dosage increased rather than decreased. AWT was, however, successful to decrease chlorine consumption. The chlorine reduction was related to the change in raw water characteristics and AWT introduction. Pre-ozonation failed to decrease coagulant consumption. The dosage increased rather than decreased. AWT was, however, successful to decrease chlorine consumption. The chlorine reduction was related to the change in raw water characteristics and AWT introduction, Both operation of pre-ozonation and reduced ammonia loading were responsible for the reduction. AWT increased the operation cost. Maintenance, raw water, and power cost increased, while labor and chemical cost decreased. Manpower reduction resulting form automation caused the decrease of labor cost. The reduction of chlorine consumption caused the decrease of chemical cost.

  • PDF

Pre-ozonation for removal of algal organic matters (AOMs) and their disinfection by-products (DBPs) formation potential

  • Jing Wang;Se-Hyun Oh;Yunchul Cho
    • Membrane and Water Treatment
    • /
    • v.14 no.2
    • /
    • pp.77-83
    • /
    • 2023
  • As a result of algal bloom, algal organic matters (AOMs) are rapidly increased in surface water. AOMs can act as precursors for the formation of harmful disinfection by-products (DBPs), which are serious problems in water treatment and human health. The main aim of this study is to characterize the formation of DBPs from AOMs produced by three different algae such as Oscillatoria sp., Anabaena sp., and Microcystis aeruginosa under different algal growth phases. In an effort to examine formation of DBPs during chlorination, chloroform (TCM), dichloroacetic acid (DCAA) and trichloroacetic acid (TCAA) were determined under various CT (product of disinfectant concentration and contact time, mg·min/L) values. Generally, the amounts of DBPs tended to increase with increasing CT values at the most growth phases. However, there was a significant difference between the amounts of DBPs produced by the three algal species at different growth phases. This result is likely due to the chemical composition variability of AOM from different algae at different growth phases. In addition, the effect of pre-ozonation on coagulation for the removal of AOMs from three algal species was investigated. The pre-ozonation had a positive effect on the coagulation/flocculation of AOMs.

Effect of Pre-ozonation on the Trans-membrane Pressure of Ceramic Membrane (전오존이 세라믹 막의 차압에 미치는 영향)

  • Bae, Byung-Uk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.9
    • /
    • pp.656-661
    • /
    • 2011
  • The performance of a domestic ceramic membrane with pore size of $0.1{\mu}m$ was evaluated to produce drinking water. A pilot-scale ceramic membrane filtration plant with a capacity of $1m^3/d$ was operated at the filtration flux of $3.0m^3/m^2{\cdot}d$ to investigate the effect of both backwash interval and pre-ozonation on TMP (trans-membrane pressure) increasing rate. The TMP increased with increasing the backwash interval. However, the application of pre-ozonation reduced the TMP increasing rate remarkably. When 1 mg/L of ozone was dosed with contact time of 5 min, TMP increasing rate at the backwash interval of 1 hr was reduced by 30%. This result indicated that pre-ozonation was very effective in reducing membrane fouling. There was almost no change in TMP increasing rate when the ozone contact time was maintained in the range of 5 to 15 min. Increasing ozone concentration up to 3 mg/L showed beneficial effect on TMP increasing rate.

Effect of Ozonation on Removal of Dissolved Organic Matter by Granular Activated Carbon Process (오존공정이 입상활성탄공정에서 용존유기물질의 제거에 미치는 영향)

  • Ahn, Hyo-Won;Chae, Seon-Ha;Wang, Chang-Keun;Lim, Jae-Lim
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.601-608
    • /
    • 2008
  • The objective of this study was to evaluate the effect of ozonation as pretreatment on the removal of dissolved or biodegradable organic matter(DOM or BOM), the variance of DOM fractionation, and microbial regrowth by pilot-scale granular activated carbon processes in which adsorption and biodegradability was proceeding due to long time operation. Regardless of point of ozonation applied, GAC processes with ozonation(i.e., Ozonation combined with GAC Filter-adsorber; Pre O$_3$ + F/A, Ozonation combined with GAC adsorber; Post O$_3$ + GAC) compared with GAC processes without ozonation(i.e., GAC Filter-adsorber; F/A, GAC adsorber; GAC) removed approximately 10 to 20% more of DOC, hydrophilic DOM(HPI), BDOC and AOC after long period of operation that biological activity was assumed to happen. Ozonation was not found to have a significant effect on the removal of DOC, but caused the decrease of AOC by approximately 20%. It was found that the fixed bacterial biomass on GAC media did not show a significant difference between the GAC with ozonation and GAC without ozonation as pre-treatment, whereas the HPC of column effluent was more biostable at Post O$_3$ + GAC compared with F/A or GAC.

오존 전처리 공정이 생물활성탄 공정의 효율에 미치는 영향

  • Lee, Sang-Hun;Mun, Sun-Sik;Sin, Jong-Cheol;Choe, Gwang-Geun;Park, Dae-Won;Sim, Sang-Jun;Lee, Jin-Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.361-364
    • /
    • 2002
  • BAC (biological activated carbon) process is a combination of biodegradation and active carbon adsorption. Pre-ozonation of raw water increased in biodegradable organic fraction. This study is to investigate the enhancement of dissolved organic matter removals by pre-ozonation process combined with BAC process at a semi-pilot scale. By biodegradation improvement in pre-ozonation process. the charge of adsorption was reduced and the life of biological activated carbon is extended. And, 48 % of total DOC was remove in the upper compartment of BAC column. The removal of the nitrogen-ammonia shows a considerably high removal ratio with 75.9 %.

  • PDF

Comparisons of Physical and Chemical Methods for Dealing with Biologically Pre-Treated Livestock Wastewater as a Post-Treatment (축산폐수 생물학적 처리수의 후처리를 위한 물리·화학적 단위 공정 비교)

  • Choi, Yong-Su;Hong, Seok-Won;Kwon, Gi-han;Jung, Il-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.2
    • /
    • pp.110-119
    • /
    • 2004
  • The combination of biological and physical/chemical technologies is a promising technique to reduce highly concentrated pollutants in livestock wastewater. It is suggested to treat livestock wastewater efficiently as follows: firstly, biodegradable organic matters, nitrogen and some of phosphorus should be removed by a biological treatment process and then residual non-biodegradable organic matters, color and phosphorus be eliminated by physicochemical technologies. In this study, therefore, the integrations of chemical coagulation, activated carbon adsorption, Fenton oxidation and ozonation were evaluated to provide appropriate post-treatment processes for biologically pre-treated livestock wastewater. After chemical coagulation followed by ozonation or Fenton oxidation process, the quality of treated wastewater could meet the discharge limit in Korea. However, a yellowish brown color still remained in the treated wastewater after a single method such as coagulation and Fenton oxidation was applied. The ozonation was found to be the most effective technology for the decolorization. Neither simple biological nor physicochemical treatment provides adequate decolorization and sufficient depletion of organics in livestock wastewater so far. Consequently, the integration of Fenton oxidation and ozonation with a biological treatment process is recommended to treat livestock wastewater in terms of removal efficiency.

The Removal of Algae by Pre-oxidation (전산화 공정을 이용한 조류제거)

  • Son, Hee-Jong;Jung, Chul-Woo;Bae, Sang-Dae;Choi, Young-Ik;Kang, Lim-Seok
    • Journal of Environmental Science International
    • /
    • v.18 no.3
    • /
    • pp.289-298
    • /
    • 2009
  • The blue-green algae which caused odor problem in the tap water are difficult to precipitate in sedimentation basin and clogged the filter void rapidly. The studies of this paper were not only oxidation, coagulation and sedimentation processes for effectively removing blue-green algae but yellow clay and polyamine for verification as coagulants aids. The results of this research are summarized as follows: Higher ozone dose(C) and longer contact time(T) were needed for a high degree of removing blue-green algae efficiency. the removal rate of blue-green algae was proportional to the $C\times T$ value. The removal percent of chlorophyll-a by sedimentation and filter without pre-ozonation was about 75% but 1 mg/L pre-ozonation could increase the removal percent of chlorophyll-a to 99% and more pre-ozonation could remove completely. Though the removal efficiency of turbidity could increased by high dose of chlorination, the dissolved organic carbon was increased. More chlorine dose from 4 to 10 mg/L dissolved organic carbon was decreased. Using yellow clay as coagulant aids increased density of floc so the settling velocity of floc become rising but polyamine could not increase settling velocity of floc though it could formated large floc.

An Application of Toxicity Test to Water Management and Water Treatment (수질관리와 수처리에의 독성시험의 응용)

  • Kim, Berm-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.639-646
    • /
    • 2005
  • In this research, we tried to develop the application method to water management and treatment using toxicity test method. When we measure the toxicity of environmental samples, we have to decide whether we take some countermeasures to reduce the toxicity or not. The first issue is how to set these action levels in each bioassays. A new idea was attempted to authorize indirect approach of each bioassays through the response characteristics against mixture of chemicals in water quality standard. The significant response in the cell-growth-inhibition bioassay was detected for standards-mixture(STDs). For acute toxicity assay, STDs-based implicit correlation between risks to humans and bioassay data showed a rational approach to set action levels in practical management. A simple model was proposed to describe and predict the changes in the total toxicity based on the concentrations of toxic-controlling chemicals during the ozonation of landfill leachates. On the basis of this simple model, toxicity reduction was predicted for pre-aggregation treatment before ozonation and ozone concentration during the ozonation. The method proposed in this study would be useful in optimizing water treatment processes and their running conditions in terms of the toxicity reduction efficacy.