펌프 베어링하우징에서 베어링과 오일의 과열 및 오일수명 예측 (Prediction of Oil Lifetime due to Overheating of Oil and Bearing Housing in a Pump)

  • 한상규;강병하;이봉주
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.408-413
    • /
    • 2004
  • An experimental study has been carried out to investigate overheating of oil and bearing housing during pump operation. This problem is of particular interest in the pre diction of lifetime and failure of pump. Transient variation of oil temperature as well as bearing housing temperature is measured to study the effect of oil viscosity, oil amount, and discharge flow rate of pump. It is found that optimal oil quantity as well as proper viscosity of oil is required to keep the safe temperature level of oil and bearing housing in a pump. The oil temperature at steady state is almost not affected by discharge flow rate in the range of discharge flow rates considered in the present study.

곡류의 유동층 건조에 관한 연구 (1) (Study on the Fluidized Bed Drying of Grains (1) - Fluidization charcteristics of Rough Rice -)

  • 허종화;서길덕
    • 대한설비공학회지:설비저널
    • /
    • 제13권3호
    • /
    • pp.168-182
    • /
    • 1984
  • For the purpose of drying high moisture rough rice effectively, from the view point of pre-drying, some basic experiments of fluidized bed drying of rough rice were carried out. The minimum fluidization velocities $(U_{mf})$ for both rough rice and glass bead were analyzed to find out fluidizing characteristics. The main results obtained were as follows ; 1) Minimum fluidization velocity of rough rice and glass bead were 2.01m/s and 4.07m/s, respectively, when using the distributor with $16\%$ opening ratio. 2) $U_{mf}$ calculated by Shirai's empirical equation and that calculated by Wen's modified equation were inconsistent with experimental data, while $U_{mf}$ calculated by Ergun's equation was consistent with the experimental data. 3) The following equations, on the basis of Leva's equation, were obtained. $$C_{mf}=1.19\times10^{-4}(Re_p)^{-0.0318)\;(rough rice)$$ $$C_{mf}=1.02imes10^{-4}(Re_p)^{-0.0047)\;(glass bead)$$

  • PDF

스마트 스페이스를 위한 난방, 환기 및 공기조화 시스템의 지능형 디지털 제어 (Intelligent Digital Control of Heating, Ventilating, and Air Conditioning System for Smart Space)

  • 김도완;박진배;주영훈
    • 제어로봇시스템학회논문지
    • /
    • 제13권4호
    • /
    • pp.365-370
    • /
    • 2007
  • This paper studies an automation problem of a heating, a ventilating, and an air conditioning (HVAC) for the development of smart space. The HVAC system is described by the fuzzy system for the stability analysis and the controller design. The linear matrix inequalities (LMIs) conditions are derived for the stabilization problem of the closed-loop system under the analog control. Also, it is required to digitally redesign the pre-designed the analog HVAC control system in order to accomplish the remote control via web. It is shown the this digital redesign problem can be converted to the convex optimization problem with the LMI constraints. An example is provided to show the effectiveness of the proposed method.

학교건물의 에너지 성능개선에 관한 연구 (A Study on the Improvement of Energy Performance in School Buildings)

  • 박진철
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.54-61
    • /
    • 2004
  • The purpose of this study is to improve of energy performance in school buildings. Many building renovations have mainly focused on commercial buildings and houses, but school buildings have no attention in this field although there are many buildings that show degraded energy performance and there are many old fashioned buildings which need renovation. This study was carried out through the survey, field study, energy simulation and life cycle cost analysis. The results of this study can be summarized as follows: In model building, large amount of heat were lost at the building envelope, such as non-insulated skins, window-sills and window-frame joints. According to the simulation result, about 15% of heating energy is saved by the insulating works compared to pre-renovation condition. Also, LCC analysis revealed to be more effective to select a exteria wall insulation such as a dryvit system.

흡습 냉각 원리를 이용한 소형 냉각 패드에 관한 연구 (Conceptual Development of a Subminiature Cool Pad Applying Sorption Cooling Effect)

  • 황용신;이대영;김우승
    • 설비공학논문집
    • /
    • 제16권2호
    • /
    • pp.121-127
    • /
    • 2004
  • This paper describes conceptual development and idea-verification of a sub-miniature portable cooler which dose not necessitate any pre-cooling nor any external energy supply. The basic principle of the cooling mechanism is the vaporization of water and sub-sequent cooling due to the evaporative latent heat loss. In this work, the vaporization of the water is stimulated by desiccant material to improve the cooling effect. The evaporative cooling caused by the desiccant is modeled and analyzed considering the sorption characteristics of the desiccant. In addition, the portable cooler is fabricated in the shape of a thin pad, and its cooling characteristics are tested and compared with the analytic results.

흡습 냉각 패드에서의 열 및 물질전달에 관한 연구 (Theoretical Analysis on the Heat and Mass Transfer in a Sorption Cool Pad)

  • 황용신;이대영;박봉철
    • 설비공학논문집
    • /
    • 제16권2호
    • /
    • pp.167-174
    • /
    • 2004
  • A sorption cool pad brings cooling effect without any pre-cooling, nor any external energy supply. It uses evaporative cooling effect stimulated by the desiccative sorption. In this paper, heat and mass transfer in the sorption cool pad are investigated theoretically. The evaporative cooling process caused by the desiccant is modeled and analyzed considering the sorption characteristics of the desiccant. Two nondimensional parameters are found to dominate the cooling process: one is related to the psychrometric characteristics and the other is to the sorption capacity of the desiccant. The former decides the time to reach the lowest temperature and the later controls the time duration of the cooling effect being sustained.

사계절 외기 전용 공조기에 대한 실험적 연구 (An Experimental Study on Four-season Dedicated Outdoor Air Handling Unit)

  • 박승태;김종천;홍영주;김영일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.577-582
    • /
    • 2008
  • The present study has been conducted to study the performance of Dedicated outdoor air handling unit. Dedicated outdoor air handling unit consists of pre-cooler, dehumidification and after cooler. By combining dedicated outdoor air-conditioning and heat pump, a new four-season dedicated outdoor air handling unit has been developed. Amount of energy saved and condition when this new system is superior to conventional vapor-compression cooling system has been presented.

  • PDF

원형 세관내 대류비등열전달에 관한 실험적 연구 (An Experimental Study of Flow Boiling Heat Transfer inside Small-Diameter Round Tubes)

  • 추원호;방광현
    • 설비공학논문집
    • /
    • 제16권8호
    • /
    • pp.748-755
    • /
    • 2004
  • Flow boiling heat transfer in small-diameter round tubes has been experimentally studied. The experimental apparatus consisted mainly of refrigerant pump, condenser, receiver, test section of a 1.67 mm inner-diameter round tube and pre-heater for control of refrigerant quality at the inlet of test section. To investigate the effect of bubble nucleation site characteristics of different tube materials, three different tubes of copper, aluminum and brass were used. The ranges of the major experimental parameters were 5∼30 ㎾/$m^2$ of the wall heat flux, 0.0∼0.9 of the inlet vapor quality and the refrigerant mass flux was fixed at 600 kg/$m^2$s. The experimental results showed that the flow boiling heat transfer coefficients in small tubes were affected only by heat flux, but independent of mass flux and vapor quality. The effect of tube material on flow boiling heat transfer was observed small.

고압용 분기배관의 사용압력에 관한 연구 (A Study on the Working Pressure of TBP Used in High Pressure)

  • 이성호
    • 설비공학논문집
    • /
    • 제22권11호
    • /
    • pp.781-787
    • /
    • 2010
  • To improve the efficiency of piping, recently the pre-fabrication piping system has been introduced, and much attention has been paid to TBPs which can replace Tee-joint. Forming and forming analysis on TBPs made from Carbon steel pipes for pressure service(KS D 3562 Sch40) and Stainless steel pipes(KS D 3576 20S) have been conducted to determine working pressure. Forming and forming analysis objects are $32A{\times}25A$, $40A{\times}25A$, $40A{\times}32A$, $50A{\times}25A$, $50A{\times}32A$, $50A{\times}40A$ TBPs.

알루미늄 호일의 친수코팅 성능 개선에 관한 실험적 연구 (Experimental study on the hydrophilic performance of pre-coated aluminum foil)

  • 김영생;길용현;박환영;윤백;김자수소;김병열
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.725-732
    • /
    • 1999
  • It is usual to use hydrophilic-coated aluminum foil for evaporator fin of air-conditioners to reduce air flow resistance caused by the water droplets condensed on the fin surface. The major effect of a hydrophilic coating is to reduce the contact angle of the condensate and prevent bridging of the condensate between the adjacent fins. The performance of hydrophilic coating generally tends to be degraded as it is used since the coating material is washed down by the condensate. In the present work, several types of hydrophilic coatings were evaluated in terms of durability of hydrophilicity, corrosion resistance and heat resistance. Results showed that an improved hydrophilic coating of resin type presented superb qualify in terms of durability and corrosion resistance while having almost the same level of qualify in heat resistance compared with the others.

  • PDF