• Title/Summary/Keyword: Pre-calibration

Search Result 162, Processing Time 0.025 seconds

The Off-Axis Properties of Solar X-Ray Telescopes: I. Evaluation of the Vignetting Effect

  • Shin, Jun-Ho;Sakurai, Takashi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.35.1-35.1
    • /
    • 2011
  • The solar X-ray telescopes, the Yohkoh SXT and the Hinode XRT, have observed for a couple of decades a variety of coronal structures in the range of wide field-of-view (FOV) covering the full solar disk. It has been emphasized that the optical structure of solar telescopes should be designed with care for improving the uniformity over the full FOV. The vignetting effect is one of the important optical characteristics for describing the performance of a telescope, which reflects the ability of collecting the incoming light at different locations and different photon energies. The correction of this vignetting effect would be an important calibration step that should be performed in advance, especially when the observed images are to be used for photometric purposes. Since the vignetting effect of solar X-ray telescopes shows wavelength dependence, a special care should be taken when, for example, performing the temperature analyses with thin and thick filters for flaring activities observed at the periphery of the full FOV. The results of analysis of pre-launch calibration data for the evaluation of vignetting effect will be introduced in detail.

  • PDF

Submillimeter continuum variability in Planck Galactic cold clumps using the JCMT-SCOPE survey

  • Park, Geumsook;Kim, Kee-Tae;Johnstone, Doug
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.48.3-48.3
    • /
    • 2019
  • In the early stages of star formation, a protostar is deeply embedded in an optically thick envelope such that it is not directly observable. Variations in the protostellar accretion rate, however, will cause luminosity changes that are reprocessed by the surrounding envelope and are observable at submillimeter wavelengths. We searched for submillimeter flux variability toward 12 Planck Galactic Cold Clumps detected by the James Clerk Maxwell Telescope (JCMT)-SCUBA-2 Continuum Observations of Pre-protostellar Evolution (SCOPE) survey. These observations were conducted at 850 ㎛ using the JCMT/SCUBA-2. Each field was observed three times over about 14 months between 2016 April and 2017 June. We applied a relative flux calibration and achieved a calibration uncertainty of ~3.6% on average. We identified 136 clumps across 12 fields and detected four sources with flux variations of ~30%. For three of these sources, the variations appear to be primarily due to large-scale contamination, leaving one plausible candidate.

  • PDF

Study on Arching Characteristics of a Grand-Section Tunnel with Pre-Steel-Rib Nail Reinforcement (대단면 터널의 선지보네일 보강에 따른 아칭특성 연구)

  • Seo, Donghyun;Cheun, Seungyul;Lee, Seungho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.6
    • /
    • pp.79-88
    • /
    • 2009
  • In this study, it was studied on arching characteristics of a grand section tunnel with pre-steel-rib nail reinforcement. In this study, we examine the adaptation of tunnel plan and the case which is based on the strengthening method for preexistence tunnel and other pre-steel-rib nail while the upper part of cover depth is low or soil condition is bad. When the pre-steel-rib nail as new technology and method reinforces the foundation placed of grand section tunnel, it is much better in strengthening effect, safety and effectiveness than the conventional one. After investigation about the plan pre-steel-rib nail method, construction case and calibration data, it was confirmed and examined about the upper part of tunnel for strengthening the pre-steel-rib nail thereby arching characteristics of grand section tunnel using MIDAS/GTS finite element program. Moreover we present the method that could upgrade the accurate installation interval and adaptation method for strengthening effect to adapt the pre-steel-rib nail method in a foundation placed over a tunnel.

  • PDF

Uniformity of Large Gypsum-cemented Specimens Fabricated by Air Pluviation Method (낙사법으로 조성된 대형 석고 고결시료의 균질성)

  • Lee, Moon-Joo;Choi, Sung-Kun;Choo, Hyun-Wook;Cho, Yong-Soon;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.1
    • /
    • pp.91-99
    • /
    • 2008
  • The method to prepare the large cemented sand specimen for calibration chamber test by air-pluviation is investigated in this study. The uniformity of cemented specimen is evaluated by performing the CPTs, DMTs, and bender element tests in the calibration chamber. The sand particles, pre-wetted with 0.5% water content, are mixed with gypsum to provide the homogeneous coating of gypsum particles on the grain surface. It was shown that the pre-wetting of particle surface is effective to minimize the potential for segregation between sands and gypsum during air-pluviation. It was observed that the extreme void ratios ($e_{max}\;and\;e_{mix}$) of the mixture of pre-wetted sand and gypsum powder increase at lower gypsum content while those of the mixture of dry sand and gypsum decrease with increasing gypsum content. It was also shown from the test results that large cemented specimens reconstituted in calibration chamber by rainer system are quite uniform in vertical and horizontal directions.

Evaluation of Chemical Composition in Reconstituted Tobacco Leaf using Near Infrared Spectroscopy (근적외선 분광분석법을 이용한 판상엽 화학성분 평가)

  • Han, Young-Rim;Han, Jungho;Lee, Ho-Geon;Jeh, Byong-Kwon;Kang, Kwang-Won;Lee, Ki-Yaul;Eo, Seong-Je
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.35 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • Near InfraRed Spectroscopy(NIRS) is a quick and accurate analytical method to measure multiple components in tobacco manufacturing process. This study was carried out to develop calibration equation of near infrared spectroscopy for the prediction of the amount of chemical components and hot water solubles(HWS) of reconstituted tobacco leaf. Calibration samples of reconstituted tobacco leaf were collected from every lot produced during one year. The calibration equation was formulated as modified partial least square regression method (MPLS) by analyzing laboratory actual values and mathematically pre-treated spectra. The accuracy of the acquired equation was confirmed with the standard error of prediction(SEP) of chemical components in reconstituted tobacco leaf samples, indicated as coefficient of determination($R^2$) and prediction error of sample unacquainted, followed by the verification of model equation of laboratory actual values and these predicted results. As a result of monitoring, the standard error of prediction(SEP) were 0.25 % for total sugar, 0.03 % for nicotine, 0.03 % for chlorine, 0.16 % for nitrate, and 0.38 % for hot water solubles. The coefficient of determination($R^2$) were 0.98 for total sugar, 0.97 for nicotine, 0.96 for chlorine, 0.98 for nitrate and 0.92 for hot water solubles. Therefore, the NIRS calibration equation can be applicable and reliable for determination of chemical components of reconstituted tobacco leaf, and NIRS analytical method could be used as a rapid and accurate quality control method.

Design and Characteristic Measurement of 8000 mm Large Aperture Integrating Sphere

  • Zhang, Zhao;Wan, Zhi;Li, Xiansheng;Liu, Hongxing;Sun, Jingxu;Liu, Zexun;Wang, Yamin;Ren, Jianwei;Ren, Jianyue
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.500-509
    • /
    • 2016
  • Integrating spheres play a central role in the radiometric calibration of remote sensors. With the development of the wide field of view (FOV) remote sensors, aperture diameters of remote sensors are becoming larger and larger. To satisfy the radiometric calibration requirements of full FOV and full aperture, an 8000mm diameter large aperture integrating sphere uniform source with a variable exit port was designed and manufactured. This integrating sphere will be used for pre-launch test and radiometric calibration of remote satellites. In this paper, optical theories were used to design the output spectral radiance. The LightTools software based on ray-tracing simulation method was used to determine the best combination and distribution of inner light sources. A spectral experiment was made to verify the spectral radiance design. To reduce the influence of longtime power-on, a new characteristic measurement method was developed to obtain the radiation characteristic of the integrating sphere, which could greatly improve the measuring efficiency. This method could also be applied to measure other large aperture uniform sources. The obtained results indicate that the spatial uniformity is 98.35%, and the angular uniformity at center position is 98.78%.

Ocean Scanning Muti-spectral Imager (OSMI) Pre-Launch Solar Calibration Radiometric Response Analysis (Ocean Scanning Muti-spectral Imager (OSMI) 발사전 태양광 보정의 복사 응답 분석)

  • 조영민
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.198-199
    • /
    • 2000
  • 다목적 실용위성 (KOMPSAT) 1호기에 탑재되는 해양관측카메라 Ocean Scanning Multi-spectral Imager (OSMI)는 해양 결상계의 노화에 따른 성능 변화 감지 및 보정을 위해 태양광 보정을 궤도운영 중 수행한다. 태양광 보정의 구조 및 광학적 특성을 분석하고 OSMI 주요 관측파장대역별로 태양광 보정계의 출력신호량을 예측하였다. 이 분석은 OSMI 센서보정 계획 및 영상 품질 이해에 유용할 것이다. (중략)

  • PDF

Experimental and numerical studies toward the implementation of shape memory alloy ties in masonry structures

  • Casciati, Sara;Hamdaoui, Karim
    • Smart Structures and Systems
    • /
    • v.4 no.2
    • /
    • pp.153-169
    • /
    • 2008
  • The use of pre-tensioned shape memory alloy (SMA) wires to retrofit historic masonry structures is investigated. A small wall, serving as a prototype masonry specimen, is constructed to undergo a series of shaking-table tests. It is first studied in its original state, and its dynamic characteristics (in terms of modal frequencies) are extracted from the recorded signals. The results are then compared with those obtained when an increasing number of couples of pre-stressed SMA wires are introduced in the specimen to link the bricks together. A three-dimensional finite element model of the specimen is developed and calibrated according to the modal parameters identified from each experimental test (with and without SMA wires). The calibration process is conducted by enhancing the masonry mechanical behaviour. The results and the effectiveness of the approach are presented.

Analysis of biodiesel quality based on infrared spectroscopy and multivariate statistics (적외선 분광분석과 다변량 통계에 기반한 바이오디젤 품질분석)

  • Kim, Hye-Sil;Cho, Hyun-Woo;Liu, J. Jay
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.214-222
    • /
    • 2012
  • ASTM (American Society for Testing and Materials) D6751-10 suggests analytical methods as well as specifications for biodiesel quality. However, it is expensive and time-consuming to follow the ASTM testing methods to analyze biodiesel and various impurities. This paper develops a quantitative analysis system for biodiesel and impurities based on Infrared spectroscopy and a multivariate statistical method, PLS (partial least squares). In addition, four different pre-processing techniques were compared for spectrum correction and noise reduction. Savitzky-Golay pre-processing showed the best performance.

Implementation and Verification of Linear Phase filter with Variable Cutoff Frequency for PCM/FM transmission (PCM/FM 전송을 위한 가변 컷오프 주파수 특성의 선형위상 필터 구현 및 검증)

  • Lee Sang-Rae;Ra Sung-Woong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.7C
    • /
    • pp.713-724
    • /
    • 2006
  • The purpose of this study is to design, implement and verify the pre-modulation filter with the variable -3dB cutoff frequency and linear phase response for bandlimiting the allocation of radio frequency bandwidth for PCM/FM transmission. For the design of this required filter, the digital FIR filter, DAC system and tuneable 2nd order LPF have been constructed and simulated according to the attenuation characteristic requirement of the amplitude frequency response by each stage. From these results, we have implemented the filter and verified the analog conversion hardware part which is composed of DAC system and tuneable 2nd order LPF for the interpolation of the discrete sequences. Especially this paper proposes and carries out the verification processes using the tone generator and the calibration procedures for more precise frequency response of the filter.