레이저 섬광법에 의한 열확산계수 측정시 적외검출소자에서 실시간 온도보정이 미치는 영향 (Effects of the in-process calibration from IR detector for thermal diffusivity measurement by laser flash method)

  • 이원식;배신철
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.795-802
    • /
    • 1998
  • For measuring the thermal diffusivity by laser flash method, raw data have to be calibrated using temperature data. We have developed in-process calibration method and polynomial calibration in which thermal diffusivity can be calibrated during measuring, This method is different from existing temperature pre-process calibration method and exponential calibration having various source of error. Using this new calibration method, measurement accuracy was improved about 1∼2% compare to the value by the existing method. We also studied more accurate fitting curve as in Figure 4 was shown the result of measuring output characteristics of IR radiometer with temperature. As illustrated in data, in-process calibration method and polynomial calibration equation is proper than pre-process calibration method and exponential calibration.

  • PDF

Characteristics of COMS MI Radiometric Calibration

  • Cho, Young-Min
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.71-74
    • /
    • 2006
  • Communication Ocean Meteorological Satellite (COMS) is planned to be launched onto Geostationary Earth Orbit in 2008. The meteorological imager (MI) is one of COMS payloads and has 5 spectral channels to monitor meteorological phenomenon around the Korean peninsular intensively and of Asian-side full Earth disk periodically. The MI has on-board radiometric calibration capabilities called 'blackbody calibration' for infrared channels and 'space look' for infrared/visible channels, and radiometric response stability monitoring device called 'albedo monitor' for visible channel. Additionally the MI has on-board function called 'electrical calibration' for the check of imaging path electronics of both infrared and visible channels. The characterization of MI performance is performed to provide the pre-launch radiometric calibration data which will be used for in-orbit radiometric calibration with the on-board calibration outputs. The radiometric calibration of the COMS MI is introduced in the view point of instrument side in terms of in-orbit calibration devices and capabilities as well as the pre-launch calibration activities and expected outputs.

  • PDF

드론 탑재 복합센서의 매핑 정확도 분석: 데이터 취득 환경에 따른 사전 캘리브레이션 여부를 중심으로 (Analysis on Mapping Accuracy of a Drone Composite Sensor: Focusing on Pre-calibration According to the Circumstances of Data Acquisition Area)

  • 전일서;함상우;이임평
    • 대한원격탐사학회지
    • /
    • 제37권3호
    • /
    • pp.577-589
    • /
    • 2021
  • 드론 매핑 시스템은 재난 피해 조사, 국토 환경 모니터링, 건설 공정 모니터링 등 여러 분야에 응용 가능하다. 드론에 장착된 다양한 개별 센서를 통합하여 활용하려면 시간동기화 등 여러가지 절차가 필요했다. 최근, 영상 센서와 GPS/INS가 함께 내장된 복합센서가 다수 출시되었다. 복합센서는 여러 가지 센서 데이터를 내부적으로 통합하여, 위치/자세를 영상 파일에 바로 태깅하여 제공한다. 이러한 복합센서를 드론 매핑 시스템에 활용하려면 매핑 정확도를 확인해 볼 필요가 있다. 이에 본 연구에서는 다양한 데이터 취득 환경과 사전 캘리브레이션 여부를 중심으로 복합센서의 매핑 정확도를 확인하였다. 첫째, 매핑 정확도가 지상기준점의 개수에 따라 어떻게 변하는지 살펴보았다. 지상기준점 개수가 2개일 때부터 총 RMSE가 1 m 이상에서 약 60 cm로 40 cm가량 줄어드는 것을 확인할 수 있었다. 둘째, 데이터 취득 상황과 사전 캘리브레이션 여부에 따른 매핑 정확도를 확인하였다. 지상기준점이 있는 경우에는 개수가 적을지라도 사전 캘리브레이션의 영향이 크지 않은 것을 확인할 수 있었다. 영상의 중복도가 충분하지 않을 때는 사전 캘리브레이션 하는 것이 정확도 개선에 영향을 주는 것을 확인할 수 있었다. 지상기준점이 없는 경우에는 카메라, 탑재체 모두 사전 캘리브레이션 하는 것이 정확도를 개선시키는데 영향이 있음을 확인하였다. 본 연구를 기반으로, 향후 복합센서를 이용한 드론 매핑 수행 시 데이터 취득 조건에 따라 지상기준점 측량과 캘리브레이션 과정을 효율화 하는데 기여할 것으로 기대한다.

DRAM bus system을 위한 analog calibration 적용 Pre-emphasis Transmitter

  • 박정준;차수호;유창식;기중식
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.653-654
    • /
    • 2006
  • A Pre-emphasis transmitter for DRAM bus system has achieved 3.2Gbps/pin operation at 1.8V supply voltage with 0.18um CMOS process. The transmitter has 800MHz PLL to generate 4 phase clocks. The 4 phase clocks are used for input clock of PRBS and multiplexing. One tap pre-emphasis is used to reduce inter symbol interference (ISI) caused by channel low pass effects. The analog calibration makes the optimized driver impedance independent with the PVT variation.

  • PDF

고차 다항식 변환 기반 카메라 캘리브레이션을 이용한 웨이퍼 Pre-Alignment 시스템 (A Wafer Pre-Alignment System Using a High-Order Polynomial Transformation Based Camera Calibration)

  • 이남희;조태훈
    • 반도체디스플레이기술학회지
    • /
    • 제9권1호
    • /
    • pp.11-16
    • /
    • 2010
  • Wafer Pre-Alignment is to find the center and the orientation of a wafer and to move the wafer to the desired position and orientation. In this paper, an area camera based pre-aligning method is presented that captures 8 wafer images regularly during 360 degrees rotation. From the images, wafer edge positions are extracted and used to estimate the wafer's center and orientation using least squares circle fitting. These data are utilized for the proper alignment of the wafer. For accurate alignments, camera calibration methods using high order polynomials are used for converting pixel coordinates into real-world coordinates. A complete pre-alignment system was constructed using mechanical and optical components and tested. Experimental results show that alignment of wafer center and orientation can be done with the standard deviation of 0.002 mm and 0.028 degree, respectively.

MU-MIMO를 위한 동적 Pre-coding을 적용한 TDD LTE-Advanced 테스트베드의 구현 (Implementation of TDD LTE-Advanced Testbed adopted Dynamic Pre-coding for MU-MIMO)

  • 한상욱;이정혁;최승원
    • 디지털산업정보학회논문지
    • /
    • 제18권2호
    • /
    • pp.27-37
    • /
    • 2022
  • In this paper, we presents a Multiple User Multiple Input Multiple Output (MU-MIMO) test-bed system for Time Division Duplex (TDD) Long Term Evolution-Advanced (LTE-A). Using two parameters, the condition number of the channel matrix and the path gain, the MU-MIMO system could switch pre-coder to maintain target Bit Error Rate (BER) level. This paper also introduces a calibration procedure for compensating error of Radio Frequency (RF) paths of the antennas and RF transceivers. From experimental measurements, dynamic pre-coding scheme could maintain target BER, set to 10-3, with the pre-coder set configured with Zero Forcing (ZF), Tomlinson Harashima Pre-coding (THP), Lattice Reduction (LR). The simplest pre-coder ZF is adopted in stable channel, and when path gain become less than 0.25, LR is adopted. Lastly, when condition number of channel matrix become larger than 7, THP is adopted.

저 Reynolds 수 영역에서 Reynolds 수가 5공 프로우브의 보정에 미치는 영향 (The Effect of Reynolds Number on the Calibration of a Five-Hole Probe at Low Reynolds Numbers)

  • 이상우;전상배
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.193-199
    • /
    • 2000
  • The effects of Reynolds number on the non-nulling calibration of a cone-type five-hole probe in low-speed flows have been investigated at the Reynolds numbers of $2.04{\times}10^3,\;4.09{\times}10^3$, and $6.13{\times}10^3$. The calibration is conducted at the pitch and yaw angles in ranges between -35 degrees and 35 degrees with an angle interval of 5 degrees. The result shows that each calibration coefficient, in general, is a function of the pitch and yaw angles, so that the pre-existing calibration data in a nulling mode are not enough in accounting for the full non-nulling calibration characteristics. Due to the interference of the probe stem, the calibration coefficients have more Reynolds number sensitivity at positive pitch angles than at negative ones.

  • PDF

적외채널 기본 복사보정 결과를 이용한 기하보정 처리의 정확도 분석 (Analysis of Geometric Calibration Accuracy using the Results from IR Channel Nominal Radiometric Calibration)

  • 서석배;권은주;진경욱
    • 항공우주기술
    • /
    • 제12권2호
    • /
    • pp.147-155
    • /
    • 2013
  • 천리안위성 기상탑재체 적외채널의 복사보정에서는 기본 복사보정식을 기반으로 다섯 개의 알고리즘이 추가되어 있다. 일반적으로 기하보정은 복사보정 이후 수행하므로, 복사보정 완료시각은 기하보정 처리의 시작시각을 결정한다. 본 논문에서는 기하보정 처리의 시작시각을 앞당기는 방법을 제안하기 위해서, 기본 복사보정 및 정밀 복사보정(기본 복사보정에 다섯 개의 알고리즘 추가) 결과를 입력으로 수행한 기하보정 처리의 정확도를 비교 분석한 내용을 정리하였다. 처리 속도가 빠른 기본 복사보정의 결과와 정확한 복사보정 값을 포함하는 정밀복사보정의 결과를 입력으로 각각의 기하보정 처리의 정확도를 분석하는 실험을 수행하였고, 두 경우 모두 기하보정 정확도 요구사항을 만족시킴을 검증하였다. 따라서 기하보정 처리 속도를 향상시키기 위해서, 기본 복사보정식으로 생성된 결과를 기하보정 처리의 입력으로 사용할 수 있음을 확인하였다.

천리안위성 기하보정 시스템의 궤도상 시험 (COMS Geometric Calibration System and Its In-Orbit Functional and Performance Tests)

  • 진경욱;서석배;김한돌;주광혁;양군호
    • 대한원격탐사학회지
    • /
    • 제27권4호
    • /
    • pp.495-506
    • /
    • 2011
  • 천리안 위성의 궤도상 시험이 위성발사 직후인 2010년 7월부터 2011년 1월까지 약 7개월에 걸쳐 성공적으로 수행되었으며, 과학탑재체인 기상 및 해양탑재체 자료는 2011년 4월부터 공식적으로 배포되고 있다. 이 논문에서는 천리안위성의 궤도상 시험 중 핵심적인 요소인 탑재체 자료의 보정 과정 중 최종 단계인 기하보정의 궤도상 테스트 내용에 중점을 두고 있다. 천리안위성 기하보정 알고리즘의 구조와 내용을 간략하게 소개하였으며, 위성발사 후 행해진 기하보정시스템의 기능 및 검증 테스트의 단계별 과정들과 그 결과를 분석 정리하였다. 실시간 위성자료 전처리 시스템을 통해 확보한 자료들을 이용한 천리안 기하보정알고리즘의 최종 성능테스트는 요구 조건을 만족하는 우수한 정확도를 보여 주었다.

2차원 격자 오차 데이터 기반의 선형 보정 함수들을 이용한 적외선 레인지 파인더 PBS-03JN의 보정 (alibration of Infra-red Range Finder PBS-03JN Using Piecewise Linear Function Based on 2-D Grid Error)

  • 김진백;김병국
    • 제어로봇시스템학회논문지
    • /
    • 제17권9호
    • /
    • pp.922-931
    • /
    • 2011
  • An efficient calibration algorithm for mobile robot localization using infrared range finder is proposed. A calibration is important to guarantee the performance of other algorithms which use sensor data because it is pre-process. We experimentally found that the infrared range finder PBS-03JN has error characteristics depending on both distance and scan angle. After obtaining 2-D grid error characteristic data on distance and scan angle, we proposed a simple and efficient calibration algorithm with a 2-D piecewise linear function set. The performance of our proposed calibration algorithm is verified by experiments and simulation.