Abstract
The nominal radiometric calibration equation and additional five algorithms are applied in the infrared channel radiometric calibration for the COMS (Communication, Ocean, Meteorological Satellite) MI (Meteorological Imager). The processing end time of the radiometric calibration is directly related with the start time of geometric calibration processing since the geometric calibration processing is followed by that of the radiometric calibration. This paper describes comparison and analysis results for geometric calibration processing using two types of the radiometric calibration results, outputs from only the nominal radiometric calibration equation and outputs from the complete one (the nominal radiometric calibration equation with additional five algorithms), to propose a method with the earlier start time of the geometric calibration processing. Experimental results show that both of radiometric calibration results, from the nominal radiometric calibration equation with a fast processing speed and from the complete one with accurate radiometric values, can be used in the geometric calibration as the appropriate inputs because those processing results satisfied the requirements of geometric calibration processing accuracy. Thus the radiometric calibration results from the nominal radiometric calibration equation can be used to improve geometric calibration processing time.
천리안위성 기상탑재체 적외채널의 복사보정에서는 기본 복사보정식을 기반으로 다섯 개의 알고리즘이 추가되어 있다. 일반적으로 기하보정은 복사보정 이후 수행하므로, 복사보정 완료시각은 기하보정 처리의 시작시각을 결정한다. 본 논문에서는 기하보정 처리의 시작시각을 앞당기는 방법을 제안하기 위해서, 기본 복사보정 및 정밀 복사보정(기본 복사보정에 다섯 개의 알고리즘 추가) 결과를 입력으로 수행한 기하보정 처리의 정확도를 비교 분석한 내용을 정리하였다. 처리 속도가 빠른 기본 복사보정의 결과와 정확한 복사보정 값을 포함하는 정밀복사보정의 결과를 입력으로 각각의 기하보정 처리의 정확도를 분석하는 실험을 수행하였고, 두 경우 모두 기하보정 정확도 요구사항을 만족시킴을 검증하였다. 따라서 기하보정 처리 속도를 향상시키기 위해서, 기본 복사보정식으로 생성된 결과를 기하보정 처리의 입력으로 사용할 수 있음을 확인하였다.