• 제목/요약/키워드: Pre-Pressure

검색결과 1,198건 처리시간 0.023초

Pressure Control of SR Driven Hydraulic Oil-Pump Using Data based PID Controller

  • Lee, Dong-Hee;Kim, Tae-Hyoung;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.800-808
    • /
    • 2009
  • This paper presents a practical method of pressure control for a hydraulic oil-pump system using an SR (Switched Reluctance) drive. For a 6Mpa grade hydraulic oil-pump, a 2.6kW SR drive is developed. In order to get high performance pressure dynamics in actual applications, a data based PID control scheme is proposed. The look-up table from a pre-measured data base produces an approximate current reference based on motor speed and oil-pressure. A PID controller can compensate for the pressure error. With the combination of the two references, the proposed control scheme can achieve fast dynamics and stable operation. Furthermore, a suitable current controller considering the nonlinear characteristics of an SRM (Switched Reluctance Motor) and practical test methods for data measuring are presented. The proposed control scheme is verified by experimental tests.

스풀형 압력제어밸브의 동특성 해석 (An Analysis of the Dynamic Characteristics of a Spool Type Pressure Control Valve)

  • 문강현;허준영
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권4호
    • /
    • pp.61-66
    • /
    • 2018
  • Almost every hydraulic system is equipped with a pressure relief valve, to maintain working pressure of the system at a pre-determined level. Thus, dynamic characteristics of such a relief valve, in conjunction with other hydraulic components, are important in designing the hydraulic control system. The single stage pressure relief valve is dynamically undesirable, due to relatively low viscous damping, that causes high frequency oscillations. This problem is overcome by introducing orifices in the inner pilot line, and drain line. In this study, for the single stage spool type pressure relief valve, the system equations were derived through an adequate linearisation and several simplifications were made, to use the transfer function formulation technique. All coefficients were evaluated and used, to make some results by using Matlab software. Results of analysis are compared with experimental results. In this study, parameters affecting stability of valve design are determined and suggested relative to the design.

SPH 기법을 활용한 Type 4 복합재료 압력용기 낙하 충격 해석 (Fall Impact Analysis of Type 4 Composite Pressure Vessels Using SPH Techniques)

  • 송귀남;김한상
    • 한국수소및신에너지학회논문집
    • /
    • 제32권3호
    • /
    • pp.172-179
    • /
    • 2021
  • The drop impact analysis was carried out on Type 4 pressure containers, and the degree of damage to the falling environment was predicted and determined using smoothed particle hydrodynamics (SPH) techniques. The purpose of the design and the optimization process of the winding pattern of the pressure vessel of the composite material is to verify the safety of the container in actual use. Finally, an interpretation process that can be implemented in accordance with domestic test standards can be established to reduce the cost of testing and containers through pre-test interpretation. The research on the fall analysis of pressure vessels of composite materials was conducted using Abaqus, and optimization was conducted using ISIGHT. As a result, the safety of composite pressure vessels in the falling environment was verified.

증기열 전처리공정을 이용한 유기성 슬러지의 건조 및 성형연료화 (Dehydration and RDF Production of Organic Sludge with Hydrothermal Pre-treatment Process)

  • 박세준;최용성;이경섭
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.526-531
    • /
    • 2009
  • This paper suggests the dehydration and RDF(Refuse Derived Fuel) production of organic sludge, livestock manure and sewerage sludge causing environmental problems, with hydrothermal pre-treatment process. The renewable technology from the organic wastes must involve short treatment time required, reusable energy source, anti-odor and viruses, low cost for the treatment, and well-fertilization. The hydrothermal pre-treatment process promotes to evaporate moisture in the sludge after being shortly treated in a reactor, which is supplied steam and heat by an external boiler, due to the pressure with steam breaks the cell walls of the sludge, so this process removes the internal moisture of the cell. Then, the treated sludge(solid-state) is mixed with waste vinyls called RDF(6,706kcal/kg).

CVD 절연막을 이용한 3C-SiC기판의 직접접합에 관한 연구 (A Study on Direct Bonding of 3C-SiC Wafers Using PECVD Oxide)

  • 정연식;류지구;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.164-167
    • /
    • 2002
  • SiC direct bonding technology is very attractive for both SiCOI(SiC-on-insulator) electric devices and SiC-MEMS applications because of its application possibility in harsh environments. This paper presents on pre-bonding according to HF pre-treatment conditions in SiC wafer direct bonding using PECVD oxide. The characteristics of bonded sample were measured under different bonding conditions of HF concentration, and applied pressure. The 3C-SiC epitaxial films grown on Si(100) were characterized by AFM and XPS, respectively. The bonding strength was evaluated by tensile strength method. Components existed in the interlayer were analyzed by using FT-IR. The bond strength depends on the HF pre-treatment condition before pre-bonding (Min : 5.3 kgf/$\textrm{cm}^2$∼Max : 15.5 kgf/$\textrm{cm}^2$).

  • PDF

중국의 병원 전 응급의료체계 개선방안 (Improvement of the pre-hospital emergency medical service system in China)

  • ;최은숙
    • 한국응급구조학회지
    • /
    • 제16권2호
    • /
    • pp.53-66
    • /
    • 2012
  • Purpose : Emergency medical services in China are increase in demand by people and under the greater pressure than ever before. So it is, necessary to advance the pre-hospital system in order to promote the development of emergency medical services. Methods : This is based on China-related articles, books, journals, reports, statistical data and other literature. Results : First, pre-hospital emergency medical care with the introduction of specialist training program should be established. Second, to strengthen pre-hospital emergency services and to develop the EMS guidelines. Third, the "120" reporting systems unification and awareness activation. Fourth, the preparation of the EMS facilities equipment system. Fifth, the rapid transport system establishment to the selected medical institutions. Conclusion : It is necessary to strengthen the emergency medical personnel at the scene, rapid transport, rapid patient triage and to improve the survival rate of the patients.

Modeling the Influence of Gas Pressure on Droplet Impact Using a Coupled Gas/liquid Boundary Element Method

  • Park, Hong-Bok;Yoon, Sam S.;Jepsen Richard A.;Heister Stephen D.
    • 한국분무공학회지
    • /
    • 제11권2호
    • /
    • pp.89-97
    • /
    • 2006
  • An inviscid axisymmetric model capable of predicting droplet bouncing and the detailed pre-impact motion, influenced by the ambient pressure, has been developed using boundary element method (BEM). Because most droplet impact simulations of previous studies assumed that a droplet was already in contact with the impacting substrate at the simulation start, the previous simulations could not accurately describe the effect of the gas compressed between a failing droplet and the impacting substrate. To properly account for the surrounding gas effect, an effect is made to release a droplet from a certain height. High gas pressures are computationally observed in the region between the droplet and the impact surface at instances just prior to impact. The current simulation shows that the droplet retains its spherical shape when the surface tension energy is dominant over the dissipative energy. When increasing the Weber number, the droplet surface structure is highly deformed due to the appearance of the capillary waves and, consequently, a pyramidal surface structure is formed; this phenomenon was verified with our experiment. Parametric studies using our model include the pre-impact behavior which varies as a function of the Weber number and the surrounding gas pressure.

  • PDF

연약지반처리와 개량효과 평가사례 (GROUND TREATMENT CASE HISTORY OFR SOFT CLAY LAYER AND EVALUATION OF ITS IMPROVEMENT)

  • 이영남;이형주;심동현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1992년도 가을학술발표회 논문집
    • /
    • pp.113-120
    • /
    • 1992
  • The construction of container terminal at Brani, Singapore required the improvement of soft clay layer having the thickness of about 6.5m, average moisture content of 79.4%, liquid limit of 90.4%, plastic limit of 21.8%, field vane strength of 10 to 25 KPa, pre-consolidation pressure of 225 to 60 KPa and compression index of 0.4 to 1.0. For the improvement of this layer, Colbon drains of 1.3m spacing in triangular pattern were installed to the bottom of the layer and surcharge of more than 11.25m high sand fill was later applied to the treated area. The settlement and lateral displacement of the ground were measured and the speed of surcharge filling was controlled, based on these readings. The removal of surcharge was determinied using the estimated time for the 90% degree of consolidation under the design pressure of 180KPa. The field and laboratory test results show that the soft clay layer has been improved substantially in its strength and consolidation characteristics: increase in strength of about 50KPa and pre-consolidation pressure and decrease in void ratio and compression index.

  • PDF

One-step형 친수무공형 폴리우레탄 수지 합성과 코팅 처리한 의류용 직물의 물성 (The Synthesis of One-step Type Hydrophilic Non-porous Polyurethane Resin and the Physical Property of its Coated Fabric for the Garment)

  • 양성용;김현아;김승진
    • 한국염색가공학회지
    • /
    • 제23권2호
    • /
    • pp.131-139
    • /
    • 2011
  • This study surveyed on the synthesis of one-step type hydrophilic non-porous PU resin and the physical property of the coated fabric for the garment. Three kinds of chain extender such as MEG, 1,4-BD and NPG were used for the preparation of one-step type hydrophilic non-porous PU resin in order to examine the effect of chain extender on the physical properties of PU-coated fabric. And the effects of isocyanate on the physical properties of PU coated fabric were surveyed by mixing with various TDI and MDI ratios. In addition, the physical properties of the coated fabric treated with one-step type hydrophilic non-porous PU resin were examined according to the pre-treatment conditions such as cire finishing. Finally, the washing durability of the coated fabrics was assessed. The coated fabrics treated with PU resin synthesized with PEG1000, MEG and TDI/MDI (6/4) showed the best physical properties. Considering the pre-treatment conditions, best performance of hydraulic pressure, water vapor permeability, and water repellency were obtained with top roller rotation ratio of 150% under 50 ton pressure at $170^{\circ}C$.