• Title/Summary/Keyword: Pre-Distortion

Search Result 179, Processing Time 0.047 seconds

Error analysis on factorization and the effect of online individualization classes (인수분해에 대한 오류 분석과 온라인 개별화 수업의 효과)

  • Choi, Dong-won;Heo, Haeja
    • Journal of the Korean School Mathematics Society
    • /
    • v.24 no.1
    • /
    • pp.83-105
    • /
    • 2021
  • In this paper, we analyzed the misconceptions and errors incurred during factorization learning. We also examined whether online individualization classes had a positive effect on students' mathematical achievement. The experiment was conducted for 4 weeks (16 times in total) on middle school juniors in rural areas of Gyeonggi Province, where the influence of private extra education was small. In the class, the 'Google Classroom' was used as a LMS, the video lecture was uploaded to YouTube, and the teacher interacted with the students through "Zoom" and "Facetalk". In the online class situation, students' assignments and test answers were checked in real time through 'Google Classroom', and immediate feedback was provided to the experimental class group's students. However, for the control group students, feedback was provided only to those who desired. A total of 7 achievement evaluations were conducted in the order of pre-test, formative evaluation (5 times), and post-test to confirm the change in students' ability improvement and achievement. Through the formative evaluation analysis, it was possible to grasp the types of errors and misconceptions that occured during the factorization process. Students' errors were divided into four types: theorem or definition distortion error, functional errors such as calculation, operation, and manipulation, errors that do not verify the solution, and no response. As a result of ANCOVA, the two groups did not show any difference from the 1st to 4th formative assessment. However, the 5th formative assessment and post-test showed statistically significant differences, confirming that online individualization classes contributed to improvemed achievement.

Evaluation of Operational Options of Wastewater Treatment Using EQPS Models (EQPS 모델을 이용한 하수처리장 운전 평가)

  • Yoo, Hosik;Ahn, Seyoung
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.401-408
    • /
    • 2018
  • EQPS (Effluent Quality Prediction System, Dynamita, France) was applied to analyze the appropriateness of the design of a bioreactor in A sewage treatment plant. A sewage treatment plant was designed by setting the design concentration of the secondary clarifier effluent to total nitrogen and total phosphorus, 10 mg/L and 1.8 mg/L, respectively, in order to comply with the target water quality at the level of the hydrophilic water. The retention time of the 4-stage BNR reactor was 9.6 hours, which was 0.5 for the pre-anoxic tank, 1.0 for the anaerobic tank, 2.9 for the anoxic tank, and 5.2 hours for the aerobic tank. As a result of the modeling of the winter season, the retention time of the anaerobic tank was increased by 0.2 hours in order to satisfy the target water quality of the hydrophilic water level. The default coefficients of the one step nitrification denitrification model proposed by the software manufacturer were used to exclude distortion of the modeling results. Since the process modeling generally presents optimal conditions, the retention time of the 4-stage BNR should be increased to 9.8 hours considering the bioreactor margin. The accurate use of process modeling in the design stage of the sewage treatment plant is a way to ensure the stability of the treatment performance and efficiency after construction of the sewage treatment plant.

Comparison of shaping ability using various Nickel-Titanium rotary files and hybrid technique (다양한 전동 니켈 티타늄 파일과 혼합사용법에 의한 근관 성형 효율 비교)

  • Kim, Jung-Won;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.530-541
    • /
    • 2007
  • Currently, various Nickel-Titanium rotary files are used in endodontic treatment, but there is no one perfect system that can be applied to any clinical situation. Therefore, the combined uses of various file systems which can emphasize the advantages of each system are introduced as hybrid instrumentation. The ProTaper system is efficient in body shaping and apical pre-enlargement but is reported to have more possibility of transportation and produce more aberrations and deformation in more or less severe curved canals. Recently, new ProTaper system(ProTaper Universal) with different configuration and cross-sectional design to overcome the week points of ProTaper have been marketed. The purpose of this study was to compare and evaluate the shaping abilities of ProTaper, ProTaper Universal system, and two hybrid methods using S-series of ProTaper Universal and Hero Shaper or ProFile. The time lapses for instrumentation were measured and the used files were inspected for distortion. The pre- and post-instrumented root canals were scanned and superimposed to evaluate the aberrations and reduction of root canal curvature and change of radius of canal curvature. The increased canal width and apical centering ratio were calculated at 1, 2, 3, 4 and 5 mm levels from apical foramen. Under the conditions of this study, the ProTaper Universal seems to have better shaping ability than ProTaper in terms of instrumented width and instrumentation time. It may be suggested that the ProTaper Universal system is efficient as much as hybrid instrumentation using ProTaper and other constant-tapered NiTi file systems in highly experienced operators.

Nonlinear Vector Alignment Methodology for Mapping Domain-Specific Terminology into General Space (전문어의 범용 공간 매핑을 위한 비선형 벡터 정렬 방법론)

  • Kim, Junwoo;Yoon, Byungho;Kim, Namgyu
    • Journal of Intelligence and Information Systems
    • /
    • v.28 no.2
    • /
    • pp.127-146
    • /
    • 2022
  • Recently, as word embedding has shown excellent performance in various tasks of deep learning-based natural language processing, researches on the advancement and application of word, sentence, and document embedding are being actively conducted. Among them, cross-language transfer, which enables semantic exchange between different languages, is growing simultaneously with the development of embedding models. Academia's interests in vector alignment are growing with the expectation that it can be applied to various embedding-based analysis. In particular, vector alignment is expected to be applied to mapping between specialized domains and generalized domains. In other words, it is expected that it will be possible to map the vocabulary of specialized fields such as R&D, medicine, and law into the space of the pre-trained language model learned with huge volume of general-purpose documents, or provide a clue for mapping vocabulary between mutually different specialized fields. However, since linear-based vector alignment which has been mainly studied in academia basically assumes statistical linearity, it tends to simplify the vector space. This essentially assumes that different types of vector spaces are geometrically similar, which yields a limitation that it causes inevitable distortion in the alignment process. To overcome this limitation, we propose a deep learning-based vector alignment methodology that effectively learns the nonlinearity of data. The proposed methodology consists of sequential learning of a skip-connected autoencoder and a regression model to align the specialized word embedding expressed in each space to the general embedding space. Finally, through the inference of the two trained models, the specialized vocabulary can be aligned in the general space. To verify the performance of the proposed methodology, an experiment was performed on a total of 77,578 documents in the field of 'health care' among national R&D tasks performed from 2011 to 2020. As a result, it was confirmed that the proposed methodology showed superior performance in terms of cosine similarity compared to the existing linear vector alignment.

The Standard of Judgement on Plagiarism in Research Ethics and the Guideline of Global Journals for KODISA (KODISA 연구윤리의 표절 판단기준과 글로벌 학술지 가이드라인)

  • Hwang, Hee-Joong;Kim, Dong-Ho;Youn, Myoung-Kil;Lee, Jung-Wan;Lee, Jong-Ho
    • Journal of Distribution Science
    • /
    • v.12 no.6
    • /
    • pp.15-20
    • /
    • 2014
  • Purpose - In general, researchers try to abide by the code of research ethics, but many of them are not fully aware of plagiarism, unintentionally committing the research misconduct when they write a research paper. This research aims to introduce researchers a clear and easy guideline at a conference, which helps researchers avoid accidental plagiarism by addressing the issue. This research is expected to contribute building a climate and encouraging creative research among scholars. Research design, data, methodology & Results - Plagiarism is considered a sort of research misconduct along with fabrication and falsification. It is defined as an improper usage of another author's ideas, language, process, or results without giving appropriate credit. Plagiarism has nothing to do with examining the truth or accessing value of research data, process, or results. Plagiarism is determined based on whether a research corresponds to widely-used research ethics, containing proper citations. Within academia, plagiarism goes beyond the legal boundary, encompassing any kind of intentional wrongful appropriation of a research, which was created by another researchers. In summary, the definition of plagiarism is to steal other people's creative idea, research model, hypotheses, methods, definition, variables, images, tables and graphs, and use them without reasonable attribution to their true sources. There are various types of plagiarism. Some people assort plagiarism into idea plagiarism, text plagiarism, mosaic plagiarism, and idea distortion. Others view that plagiarism includes uncredited usage of another person's work without appropriate citations, self-plagiarism (using a part of a researcher's own previous research without proper citations), duplicate publication (publishing a researcher's own previous work with a different title), unethical citation (using quoted parts of another person's research without proper citations as if the parts are being cited by the current author). When an author wants to cite a part that was previously drawn from another source the author is supposed to reveal that the part is re-cited. If it is hard to state all the sources the author is allowed to mention the original source only. Today, various disciplines are developing their own measures to address these plagiarism issues, especially duplicate publications, by requiring researchers to clearly reveal true sources when they refer to any other research. Conclusions - Research misconducts including plagiarism have broad and unclear boundaries which allow ambiguous definitions and diverse interpretations. It seems difficult for researchers to have clear understandings of ways to avoid plagiarism and how to cite other's works properly. However, if guidelines are developed to detect and avoid plagiarism considering characteristics of each discipline (For example, social science and natural sciences might be able to have different standards on plagiarism.) and shared among researchers they will likely have a consensus and understanding regarding the issue. Particularly, since duplicate publications has frequently appeared more than plagiarism, academic institutions will need to provide pre-warning and screening in evaluation processes in order to reduce mistakes of researchers and to prevent duplicate publications. What is critical for researchers is to clearly reveal the true sources based on the common citation rules and to only borrow necessary amounts of others' research.

EFFECT OF DECALCIFIED FREEZE-DRIED ALLOGENEIC BONE GRAFT(DFDB) ON THE JAW DEFECTS AFTER CYST ENUCLEATION (낭종 적출후 악골 결손부 치유에 관한 동종골 이식 효과에 관한 연구)

  • Lee, Dong-Keun;Min, Seung-Ki;Kwon, Kyung-Hwan;Sung, Hun-Mo;Park, Hwa-Kyu;Kang, Mun-Jeong;Sin, Ki-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.4
    • /
    • pp.360-365
    • /
    • 1999
  • This study was aimed to suggest to better treatment method of jaw cyst that the maximum diameter was wider than 3cm, using different treatment and clinical and radiographic result. We divided the 60 patients into three groups, group A(20 patients) were treated with cyst enucleation and Decalcified Freeze-Dried Allogeneic Bone(DFDB) graft, group B(20 patients) were treated with cyst enucleation and autogenous bone graft, group C(20 patients) were treated with only cyst enucleation. Each group was evaluated with panoramic radiograph and clinical sign & symptom at pre-op and post-op(immediate, 6, 12, 24, 36 month). Bone density was evaluated with disital densitometer. The result was as follows : 1. Post-Op infection was higher in group C(4 pts.) than in group A(1 pt.) and B(1 pt.) 2. Post-Op gingival recession was higher in group C(3 Pts.) than in group A(1 pt.) and B(1 pt.) 3. Anatomic distortion was higher in group C(3 Pt.) than in group A(1 Pt.), and B(1 pt.) 4. Reoperation was done in two patients who were in group C 5. There were donor site morbidity in two patients 6. There was no significant difference between group A and B in their bony density in their follow up period(p>0.05). 7. There were significant differences between group A, B and group C in their bony density until post-op 24 months but a little differences at post-op 36 months(P<0.01)

  • PDF

Relative efficacy of three Ni-Ti file systems used by undergraduates (학생들이 사용한 세 종류 Ni-Ti file systems의 근관성형 효율 비교)

  • Kim, Hyeon-Cheol;Park, Jeong-Kil;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.38-48
    • /
    • 2005
  • The purpose of this study was to compare and evaluate the shaping ability of the three different Ni-Ti file systems used by undergraduate students. Fifty undergraduate students prepared 150 simulated curved root canals in resin blocks with three Ni-Ti file systems - $ProFile^{(R)}$ (PF), Manual $ProTaper^{(R)}$ (MPT), Rotary $ProTaper^{(R)}$ (RPT). Every student prepared 3 simulated root canals with each system respectively. After root canal preparation, the Ni-Ti files were evaluated for distortion or breakage Assessments were made according to the presence of various types of canal aberrations. The pre- and post-instrumented canal images were attained and superimposed. The instrumented root canal width were measured and calculated for the net transportation (deviation) and the centering ratio. Under the condition of this study, both $ProTaper^{(R)}$ systems allowed significantly more removal of root canal wall than the $ProFile^{(R)}$ system. In the important other aspects such as the centering ratio, there was no significant differences between the systems. Novice dental students were able to prepare curved root canals with any kinds of Ni-Ti file systems with little aberration and great conservation of tooth structure. Students want to learn effective methods and at the same time simple rotary procedures. The rotary $ProTaper^{(R)}$ systems were one of the most compatible to these students from the point of view of cutting ability The $ProFile^{(R)}$ system was also compatible in safe and gentle shaping.

EFFECT OF ROTATIONAL SPEED OF PROTAPERTM ROTARY FILE ON THE CHANCE OF ROOT CANAL CONFIGURATION (ProTaperTM로 근관성형시 회전 속도 변화가 근관형태에 미치는 영향)

  • Seo, Min-Chul;Jeon, Yoon-Jeong;Kang, In-Chol;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.3
    • /
    • pp.179-185
    • /
    • 2006
  • This study was conducted to evaluate canal configuration after shaping by $ProTaper^{TM}$ with various rotational speed in J-shaped simulated resin canals. Forty simulated root canals were divided into 4 groups, and instrumented using by $ProTaper^{TM}$ at the rotational speed of 250, 300, 350 and 400 rpm. Pre-instrumented and post-instrumented images were taken by a scanner and those were superimposed. Outer canal width, inner canal width, total canal width, and amount of transportation from original axis were measured at 1, 2, 3, 4, 5, 6, 7 and 8 mm from apex. Instrumentation time, instrument deformation and fracture were recorded. Data were analyzed by means of one-way ANOVA followed by Scheffe's test. The results were as follows 1. Regardless of rotational speed, at the $1{\sim}2mm$ from the apex, axis of canal was transported to outer side of a curvature, and at 3~6 mm from the apex, to inner side of a curvature. Amounts of transportation from original axis were not sienifcantly different among experimental groups except at 5 and 6 mm from the apex. 2. Instrumentation time of 350 and 400 rpm was significantly less than that of 250 and 300 rpm (p<0.01). In conclusion the rotational speed of $ProTaper^{TM}$ files in the range of $250{\sim}400rpm$ does not affect the change of canal configuration, and high rotational speed reduces the instrumentation time. However appearance of separation and distortion of Ni-Ti rotary files can occur in high rotational speed.

RPC Correction of KOMPSAT-3A Satellite Image through Automatic Matching Point Extraction Using Unmanned AerialVehicle Imagery (무인항공기 영상 활용 자동 정합점 추출을 통한 KOMPSAT-3A 위성영상의 RPC 보정)

  • Park, Jueon;Kim, Taeheon;Lee, Changhui;Han, Youkyung
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.1135-1147
    • /
    • 2021
  • In order to geometrically correct high-resolution satellite imagery, the sensor modeling process that restores the geometric relationship between the satellite sensor and the ground surface at the image acquisition time is required. In general, high-resolution satellites provide RPC (Rational Polynomial Coefficient) information, but the vendor-provided RPC includes geometric distortion caused by the position and orientation of the satellite sensor. GCP (Ground Control Point) is generally used to correct the RPC errors. The representative method of acquiring GCP is field survey to obtain accurate ground coordinates. However, it is difficult to find the GCP in the satellite image due to the quality of the image, land cover change, relief displacement, etc. By using image maps acquired from various sensors as reference data, it is possible to automate the collection of GCP through the image matching algorithm. In this study, the RPC of KOMPSAT-3A satellite image was corrected through the extracted matching point using the UAV (Unmanned Aerial Vehichle) imagery. We propose a pre-porocessing method for the extraction of matching points between the UAV imagery and KOMPSAT-3A satellite image. To this end, the characteristics of matching points extracted by independently applying the SURF (Speeded-Up Robust Features) and the phase correlation, which are representative feature-based matching method and area-based matching method, respectively, were compared. The RPC adjustment parameters were calculated using the matching points extracted through each algorithm. In order to verify the performance and usability of the proposed method, it was compared with the GCP-based RPC correction result. The GCP-based method showed an improvement of correction accuracy by 2.14 pixels for the sample and 5.43 pixelsfor the line compared to the vendor-provided RPC. In the proposed method using SURF and phase correlation methods, the accuracy of sample was improved by 0.83 pixels and 1.49 pixels, and that of line wasimproved by 4.81 pixels and 5.19 pixels, respectively, compared to the vendor-provided RPC. Through the experimental results, the proposed method using the UAV imagery presented the possibility as an alternative to the GCP-based method for the RPC correction.