• Title/Summary/Keyword: Practical dynamic load

Search Result 109, Processing Time 0.028 seconds

Design Parameter Study on the Isolation Performance of the HSLDS Magnetic Vibration Isolator (HSLDS 마그네틱 진동절연체의 절연성능에 대한 설계 파라미터 분석)

  • Shin, Ki-Hong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.1
    • /
    • pp.92-97
    • /
    • 2010
  • In general, the softer the stiffness of a linear vibration isolator the better the performance of isolation can be achieved. However, the stiffness of the isolator cannot be made too soft because it needs a sufficient stiffness to hold the load. This is the most critical limitation of a linear vibration isolator. Recently, a HSLDS(high-static-low-dynamic-stiffness) magnetic vibration isolator was proposed to overcome this fundamental limitation. The suggested isolator utilizes two pairs of attracting magnets that introduces negative stiffness. Previously, this new type of vibration isolator was merely introduced and showed a possibility of practical use. In this paper, detailed dynamics of the HSLDS magnetic isolator are studied using computer simulations. Then, the isolation performance is examined for various design parameters to aid the practical use.

Study of Static/Dynamic Load Model by measurement (실측에 의한 Static/Dynamic 부하모델 개발 연구)

  • Choi, H.K.;Moon, Y.H.;Yoon, J.Y.;Jeon, J.H.;Choo, J.B.;Yun, Y.B.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.58-60
    • /
    • 2000
  • This paper presents the modeling methods to analyze the static and dynamic performances for practical power system loads using field measurement data. Also, it is included that the several modeling techniques using EMTDC program and field measuring method for real static dynamic loads. As a result of this study, through the comparisons between simulation results and measurement data, typical parameters of static and dynamic loads according to the variation of system voltage and frequency are given.

  • PDF

Dynamic Analysis of Gear System Using G.U.I. Program (G.U.I. 프로그램을 이용한 기어 시스템의 동적 해석)

  • 박왕준;윤구영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.857-860
    • /
    • 1996
  • The area of gear dynamics has recently been the focus of many studies. A new tooth profile modification was proposed by author for reducing vibration and noise of involute gears. A comparative dynamic analysis of the gear drive with the involute tooth and the modified tooth profile(using cubic splines) is performed to the unuformal transmission error reduces the gear vibration and noise due to less dynamic tooth load variation during the meshing cycle. This work also include a gear design process by the meaning of a practical approach, such as Win95 based simulation program with all using basic geardesign variables. Especially this program enables gear designers to dynamic analysis based on G.U.I.

  • PDF

Determination of optimal unit commitment and load dispatch for thermal power system by DP method (DP법에 의한 화력계통의 최적병렬치수 결정 및 부하배분)

  • 양흥석;이문호
    • 전기의세계
    • /
    • v.21 no.2
    • /
    • pp.34-40
    • /
    • 1972
  • This paper describes the problem of the shortange-economic-scheduling for unit commitment and load dispatching in thermal power system. For economic operation of thermal system, the optimum time of startup and shoutdown of the generating unit must be determined so as to minimize the sum of generating and starting fuel cost over a given period. The above problems are analyzed for the purpose of the application of Dynamic Programing Method. Also the technique of Dynamic Programming is applied to the problems. For the illustative purpose, a case study was made on a model system composed of eight units and the computing time was about 190 seconds by IBM 360-40 system. Therefore, one can utilize this suggested method on any of the practical power systems.

  • PDF

On the Analysis of Dynamic Characteristics of Pipe Supporting Hydraulic Snubber in Electric Power Plant with State-space Model and Impulse Testing (상태공간 모델과 임펄스 시험에 의한 발전소 배관지지용 유압완충기의 동특성 해석)

  • Lee, Jae-Cheon;Im, Mun-Hyeok;Hwang, Tae-Yeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.10
    • /
    • pp.130-138
    • /
    • 2002
  • This paper presents the modeling and analysis of dynamic characteristics of hydraulic snubber in electric power plant. The nonlinear state-space model of 14th order to describe the dynamics of the snubber was established by Simulink. The simulation results show that the hydraulic snubber reacts as like the conventional shock absorbers against the high pulse shock load. The snubber also shows the peculiar characteristics to the small step load, which temporarily lock the control valves up, however maintain same steady-state pressures of all internal chambers in the long run. Two case studies for the analysis of the snubber were addressed. Practical pulse testing method was also proposed to identify the frequency response characteristics of the snubber.

On the Analysis of Dynamic Characteristics of Pipe Supporting Hydraulic Snubber in Electric Power Plant with State-space Model and Impulse Testing (상태공간 모델과 임펄스 시험에 의한 발전소 배관지지용 유압완충기의 동특성 해석)

  • Lee, Jae-Cheon;Hwang, Tae-Yeong
    • 연구논문집
    • /
    • s.31
    • /
    • pp.89-99
    • /
    • 2001
  • This paper presents the modeling and analysis of dynamic characteristics of hydraulic snubber in electric power plant. The nonlinear state-space model of 14th order to describe the dynamics of the snubber was established by Simulink. The simulation results show that the hydraulic snubber reacts as like the conventional shock absolvers against the high pulse shock load. The snubber also shows the peculiar characteristics to the small step load, which temporarily lock the control valves up, however maintain same steady-state pressures of all internal chambers in the long run. Two case studies for the analysis of the snubber are addressed. Practical pulse testing method was also proposed to identify the frequency response of the snubber.

  • PDF

Proof Load Test and Integrity Assessment of Segmental PC Box-girder Bridges (Segmental PC 박스거더교의 검증재하시험 및 건전성평가)

  • 조효남;임종권;옥승범;지광습
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.10a
    • /
    • pp.132-141
    • /
    • 1995
  • This study is intended to propose practical but systematic and rational approaches for proof load test and integrity assessment of segmental PC box-girder bridges. The proposed models cover the whole range of field tests and assessment of such as inspections, nondestructive tests, static and dynamic load tests, structural analysis, and integrity assessment for the evaluation of load carrying capacity, serviceability, and durability of PC box-girder bridges. They are applied to a newly constructed precast segmental PC box-girder bridge which is a part of the Seoul interior circuit elevated expressway.

  • PDF

An Analytical Review of the Dynamic Interactions between Tilting Train and Welded Plate Girder Bridges (틸팅차량과 용접형 판형교의 동적 상호작용에 관한 해석적 고찰)

  • Lee Hee Up;Um Ju Hwan;Ku Su Hwan;Go Dong Choon
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.596-601
    • /
    • 2003
  • After the development of practical technology for tilting system, tilting trains are operated on conventional lines of KORAIL. As the running speed of trains is increased, it is very important to investigate the dynamic characteristics of plate girder bridges with direct track fixation. Therefore, this paper reviews the dynamic interactions between tilting train and welded plate girder bridges designed by L-22, a standard load type of KORAIL. The span lengths of plate girder analyzed here are 6.6m, 9.7m, 12.9m, 16.0m, 19.2m, 22.3m, 25.4m and 31.1m. Using 2-D dynamic analysis, the critical velocity of tilting train, vertical deflection ratios of plate girder and maximum accelerations of car body are calculated. And the analytical results are compared with those of design criteria.

  • PDF

A new conjugate gradient algorithm for solving dynamic load identification

  • Wang, Lin J.;Deng, Qi C.;Xie, You X.
    • Structural Engineering and Mechanics
    • /
    • v.64 no.2
    • /
    • pp.271-278
    • /
    • 2017
  • In this paper, we propose a new conjugate gradient method which possesses the global convergence and apply it to solve inverse problems of the dynamic loads identification. Moreover, we strictly prove the stability and convergence of the proposed method. Two engineering numerical examples are presented to demonstrate the effectiveness and speediness of the present method which is superior to the Landweber iteration method. The results of numerical simulations indicate that the proposed method is stable and effective in solving the multi-source dynamic loads identification problems of practical engineering.

Soft-Switched PWM DC-DC High-Power Converter with Quasi Resonant-Poles and Parasitic Reactive Resonant Components of High-Voltage Transformer (부분 공진형 소프트 스위칭 PWM DC-DC 고전압 컨버터)

  • 김용주;신대철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.384-394
    • /
    • 1999
  • This paper deals with a fixed frequency full-bridge inverter type DC-DC high-power converter with high frequency high voltage(HFHV) transformer-coupled stage, which operates under quasi-resonant ZVS transition priciple in spite of a wide PWM-based voltage regulation processing and largely-changed load conditions. This multi-resonant(MR) converter topology is composed of a series capacitor-connected parallel resonant tank which makes the most of parasitic circuit reactive components of HFHV transformer and two additional quasi-resonant pole circuits incorporated into the bridge legs. The soft-switching operation and practical efficacy of this new converter circuit using the latest IGBTs are actually ascertained through 50kV trially-produced converter system operating using 20kHz/30kHz high voltage(HV) transformers which is applied for driving the diagnostic HV X-ray tube load in medical equipments. It is proved from a practical point of view that the switching losses of IGBTs and their electrical dynamic stresses relating to EMI noise can be considerably reduced under a high frequency(HF) switching-based phase-shift PWM control process for a load setting requirements.

  • PDF