• Title/Summary/Keyword: Pps

Search Result 400, Processing Time 0.022 seconds

Development of 3.6 MW, 4 ${\mu}s$, 200 pps Pulse Modulator for a High power magnetron (고출력 마그네트론 구동용 3.6 MW, 4 ${\mu}s$, 200 pps 펄스모듈레이터 개발)

  • Son, Y.G.;Jang, S.D.;Oh, J.S.;Cho, M.H.;NamKang, W.;Lee, H.K.;Bae, Y.S.;Lee, K.T.;Son, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1778-1780
    • /
    • 2004
  • Microwave heating system of KSTAR consists of ECH and LHCD. ECH and LHCD offer the reliability of operation in the beginning of plasma formation and non-inductive current drive for long time steady state operation with maintaining MHD stability, respectively. LHCD demands 5 GHz of frequency and consists of c-band waveguide, 4-port circuitor, dry dummy load, dual directional coupler, E-bend, arc detector. Our system is a lineup type pulse modulator that has 45 kV of output pulse voltage, 90 A of pulse current, 4 us of pulse width. 1:4 step-up pulse transformer, 7 stages of PFN and thyratron tube (E2V, CX1191D) are used in this modulator. The purpose of this paper is to show the modulator design and experimental result.

  • PDF

A study on the logistics effectiveness in the receptacles & bottles manufacturers by introducing Packing resource Pool System (포장자재 풀시스템 도입을 통한 제관(CAN병).제병(PET병)업계 물류효율화에 관한 연구)

  • Park, In-Sul;Kwon, An-Sik;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.3
    • /
    • pp.63-71
    • /
    • 2007
  • Recently, many companies knock themselves out to reduce logistics costs. However, they have reached the limit on cost reducing by improving the manufacturing process. In addition, Customers are growing more and more particular about the quality. Also the firms, which provide foods & beverages manufacturer with vacant receptacles and bottles, make zealous efforts to save costs. They have tried to seek for the resolution by own investment and improving system, but they haven't found certainly substitutions. In this study, we analyze problems of the vacant receptacles manufacturers and present introduction of pool system by standardization of Packing Resource. This PPS(Packing resource Pool System) will enable to reduce logistics cost that is challenge for the receptacles & bottles manufacturers, be helpful reducing environmental disruption which are the pollution of alien substances, wasted paper sheets because the system cleans retrieved Packing resources and reuses them.

Sterilization of Escherichia coli Based on Nd: YAG Resonator with a Pulsed Xenon Flashlamp

  • Kim, Hee-Je;Kim, Dong-Jo;Hong, Ji-Tae;Xu, Guo-Cheng;Lee, Dong-Gil
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.275-279
    • /
    • 2011
  • Sterilization of Escherichia coli (E. coli) is examined using a unique pulsed ultra-violet (UV) elliptical reactor based on Nd:YAG laser resonator, UV radiation from a pulsed xenon flashlamp. The light from the discharge has a broadband emission spectrum extending from the UV to the infrared region with a rich UV contained. Sterilization method by using the UV light is fast, environment-friendly and it does not cause secondary pollution. A Nd:YAG laser resonator having elliptical shape has advantage of concentrating the radiation of the UV light at two foci as the quart sleeve filled with E. coli. The primary objective of this research is to determine the important parameters such as pulse per second (pps), the applied voltage for sterilizing E. coli by using an UV elliptical reactor. From the experiment result, the sterilization effect of UV elliptical reactor is better than that of UV cylindrical reactor, and it can be 99.9% of sterilization at 800V regardless of the pps within 10 minutes.

Research on the Multi - purpose Nd:YAG Laser Power System using LLC Converter (LLC 공진형 컨버터를 사용한 다용도 Nd:YAG 레이저 전원장치 설계)

  • Zheng, Tao;Kim, Hee-Je;Lee, Jae-cheol;Xu, Guo-Cheng
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.6
    • /
    • pp.885-890
    • /
    • 2015
  • LLC resonant converter has been widely used because of its high efficiency and high energy density. In this paper, we designed a LLC resonant converter as the main power supply of the Nd:YAG pulse laser. First harmonic approximation (FHA) is used to model the LLC resonant converter. FHA equivalent circuit model and the transfer function of the LLC resonant converter is proposed. Soft start technology is also used to suppress the surge current. The laser output simulation test result is identical with the practical test, the laser energy of every pulse can reach up to 2.5J, and the pulse per second (PPS) can be adjusted from 6 to 18. The power system is verified stable and reliable by both of the simulation and experiment results.

Design and Operation Characteristics of 2.4MJ Pulse Power System for Electrothermal-Chemical (ETC) Propulsion (II) (전열화학추진용 2.4MJ 펄스파워전원의 설계와 동작특성(II))

  • Jin, Y.S.;Lee, H.S.;Kim, J.S.;Whang, D.W.;Kim, J.S.;Chu, J.H.;Jung, J.W.;Moon, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1603-1605
    • /
    • 2001
  • Eight 300kJ modularized capacitor-banks have been constructed. These modules have been installed and assembled to make a 2.4MJ pulse power system (PPS). This 2.4MJ PPS was developed to be used as a driver of an electrothermal-chemical (ETC) gun. Each capacitor bank has six 22kV, 50kJ capacitors connected in parallel. A triggered vacuum switch (TVS-43) was adopted as a main pulse power-closing switch in each module. The module also contains a crowbar circuit made of three high-voltage diode-stacks, a multi-tap inductor and an energy-dumping resistor. Various current shapes have been formed by a sequential firing of multiple capacitor banks. Resistive dummy load has been used and various combinations of experimental parameters, such as charging voltage, trigger time and inductance, were tested to make flexible current shapes.

  • PDF

Design of SOI CMOS image sensors using a nano-wire MOSFET-structure photodetector (나노 와이어 MOSFET 구조의 광검출기를 가지는 SOI CMOS 이미지 센서의 픽셀 설계)

  • Do, Mi-Young;Shin, Young-Shik;Lee, Sung-Ho;Park, Jae-Hyoun;Seo, Sang-Ho;Shin, Jang-Kyoo;Kim, Hoon
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.387-394
    • /
    • 2005
  • In order to design SOI CMOS image sensors, SOI MOSFET model parameters were extracted using the equation of bulk MOSFET model parameters and were optimized using SPICE level 2. Simulated I-V characteristics of the SOI NMOSFET using the extracted model parameters were compared to the experimental I-V characteristics of the fabricated SOI NMOSFET. The simulation results agreed well with experimental results. A unit pixel for SOI CMOS image sensors was designed and was simulated for the PPS, APS, and logarithmic circuit using the extracted model parameters. In these CMOS image sensors, a nano-wire MOSFET photodetector was used. The output voltage levels of the PPS and APS are well-defined as the photocurrent varied. It is confirmed that SOI CMOS image sensors are faster than bulk CMOS image sensors.

A Study on the Improvement of Accuracy of Close-Range Photogrammetry Analysis by Using Non-metric Camera (비측량용(非測量用) 사진기(寫眞機)에 의(依)한 근접사진(近接寫眞) 해석(解析)의 정확도(正確度) 향상(向上)에 관(關)한 연구(研究))

  • Kang, Joon Mook;Oh, Won Jin;Han, Seung Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.151-159
    • /
    • 1992
  • In close-range photogrammetry, to employ non-metric camera especially for the purpose of precise measurement, systematic errors must, first of all, be corrected as they have a great influence on accuracies of results. For it, fiducial marks was built in non-metric camera and the factors such as PPS, PPA, EFL, CFL, and radial lens distortion coefficients for each quadrant were calibrated through collimator test. Also, the coefficients of both radial and tangential lens distortion were calibrated from analytical plumb line method and therefore main systematic errors could be effectively corrected. Using the calibrated non-metric camera, close-range photogrammetry could be successfully accomplished and accuracies could be improved sharply.

  • PDF

A Study on the Characteristics of the Hybrid Carbons Filled Poly(Phenylene Sulfide) Composite Bipolar Plates of Fuel Cell (하이브리드카본이 충전된 Poly(Phenylene Sulfide) 복합재 연료전지 분리판 특성 연구)

  • Kim, Nam-Hoon;Park, Ok-Kyung;Lee, Chang-No;Lee, Joong-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.172-175
    • /
    • 2009
  • A bipolar plate is an important component in a fuel cell in the sense of cost and weight. This study aimed at developing highly conductive, lightweight, and low cost bipolar plates. Hybrid carbons filled poly(phenylene sulfide)(PPS) composite bipolar plates were prepared by using the compression molding technique. Various types and amounts of conducting carbon fillers such as graphite, carbon black, carbon fibers, and carbon nanotubes (CNTs) were adopted for the composites. Electrical conductivity and mechanical properties of the composites were measured in order to investigate effects of each components of fillers. When the graphite is only used as a conducting filler, the electrical conductivity of the composites increases with increasing the content, but the flexural strength decreases dramatically. However, for CNTs and carbon fibers, the flexural strength initially increases and then decreases with increasing the amount of the conducting fillers. The amount of graphite corresponding to the peak of flexural strength was moved to lower content with increasing the amount of CNTs or carbon fiber. When hybrid conducting fillers such as fibrous and particulate fillers were used, the synergy effect in mechanical and electrical properties was observed.

  • PDF

Relation between Body Mass Index and Pattern Identification in Obese Adolescents (비만 청소년에서 체질량지수와 한의변증의 상관성)

  • Park, Jang-Kyung;Kim, Kyeong Han
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.21 no.2
    • /
    • pp.55-60
    • /
    • 2017
  • Objectives : This study was conducted to analysis correlation of pattern identification and body mass index (BMI) in obese adolescents. Methods : A total of 228 middle school students, 226 students were agreed and included study and two were excluded because of disagreement. It was conducted cold-heat pattern questionnaire, phlegm pattern questionnaire and after height and weight were measured. Firstly, out of 24 who did not respond to all of questionnaires. Secondary, out of 159 who are normal range on international obesity standard(BMI < $30kg/m^2$) Results : The average height and weight of 43 subjects was $159.65{\pm}9.45cm$, $70.10{\pm}8.47kg$ respectively. The average score of pattern identification was cold pattern score(CPS) was $2.70{\pm}1.61$, heat pattern score(HPS) was $3.30{\pm}1.99$, phlegm pattern score(PPS) was $3.95{\pm}5.02$. There was no significant correlation with BMI and CPS, HPS, PPS. Conclusions : In this study, there was no significant correlation of pattern identification and BMI in obese adolescents.