• Title/Summary/Keyword: Power-Saving

Search Result 1,284, Processing Time 0.03 seconds

Study of the Characteristic and Optimization of Induction Lamp according to Gas Pressure and Amalgam Type (고출력 무전극램프의 가스압 및 아말감종류에 따른 특성분석 및 최적화에 관한 연구)

  • Chung, Young-Il;Jung, Dae-Chul;Kim, Yong-Kab;Park, Dae-Hee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.1
    • /
    • pp.23-30
    • /
    • 2017
  • Currently, road lightings are installed with less than 400W of existing metal halide lamps. These road lightings are being replaced by energy-saving lightings. Induction lamps are expected to be more actively replaced with targets for tunnel lighting and high ceiling lighting. Therefore, it is necessary to develop high efficiency, high power induction lamps system. In this study, the gas type & pressure, amalgam type were designed for the high power of the induction lamps. And induction lamp system was optimized through electrical, optical characteristics analysis. It is optimized to the gas pressure 300~350 [mmHg] for the discharge tube of high power induction lamp and ferrite core. The driving circuit matching was completed with a induction lamp using indium amalgam. The rated power consumption of the induction lamp was optimized with 250 W (rated ${\pm}10%$)

Simulated Optimum Substrate Thicknesses for the BC-BJ Si and GaAs Solar Cells

  • Choe, Kwang-Su
    • Korean Journal of Materials Research
    • /
    • v.22 no.9
    • /
    • pp.450-453
    • /
    • 2012
  • In crystalline solar cells, the substrate itself constitutes a large portion of the fabrication cost as it is derived from semiconductor ingots grown in costly high temperature processes. Thinner wafer substrates allow some cost saving as more wafers can be sliced from a given ingot, although technological limitations in slicing or sawing of wafers off an ingot, as well as the physical strength of the sliced wafers, put a lower limit on the substrate thickness. Complementary to these economical and techno-physical points of view, a device operation point of view of the substrate thickness would be useful. With this in mind, BC-BJ Si and GaAs solar cells are compared one to one by means of the Medici device simulation, with a particular emphasis on the substrate thickness. Under ideal conditions of 0.6 ${\mu}m$ photons entering the 10 ${\mu}m$-wide BC-BJ solar cells at the normal incident angle (${\theta}=90^{\circ}$), GaAs is about 2.3 times more efficient than Si in terms of peak cell power output: 42.3 $mW{\cdot}cm^{-2}$ vs. 18.2 $mW{\cdot}cm^{-2}$. This strong performance of GaAs, though only under ideal conditions, gives a strong indication that this material could stand competitively against Si, despite its known high material and process costs. Within the limitation of the minority carrier recombination lifetime value of $5{\times}10^{-5}$ sec used in the device simulation, the solar cell power is known to be only weakly dependent on the substrate thickness, particularly under about 100 ${\mu}m$, for both Si and GaAs. Though the optimum substrate thickness is about 100 ${\mu}m$ or less, the reduction in the power output is less than 10% from the peak values even when the substrate thickness is increased to 190 ${\mu}m$. Thus, for crystalline Si and GaAs with a relatively long recombination lifetime, extra efforts to be spent on thinning the substrate should be weighed against the expected actual gain in the solar cell output power.

Development of High Efficiency Contactless Power Supply System for Stocker System (Stocker 시스템에 적용한 고효율 비접촉 전원시스템 개발)

  • Hwang, Gye-Ho;Kim, Won-Gon;Yun, Jong-Bo;Moon, In-Ho;Lee, Bong-Seob;Min, Byung-Jae;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.77-85
    • /
    • 2010
  • Recently, As increasing cleanroom size, Stocker system is trending the large size and long distance for LCD material transfer system In order to rise a rate of production, the manufacturer are on the decrease of total tact time with Stocker system And the manufacturer are requested to high speed of next generation Stocker system Also manufacturers for the high oil prices through energy-saving conservation to minimize plant operating costs are required. Therefore, this paper propose optimal design of high efficiency Contactless Power Supply(CPS) system about high speed and energy savings of next generation Stocker system This paper proposes CPS system is applied in the long distance and straight section with Stocker system for energy savings. The test results of input!output characteristic and efficiency of CPS system on operating pattern of Stocker system were analyzed, and proved the applicability on commercial use.

The Analysis of Energy Cost Adopting an Electric Residence using Historical Energy Consumption Data (에너지소비 데이터를 이용한 전전화 주택 도입시 에너지 사용량 분석)

  • Lee, Jun-Kyu;Shin, Hee-Sang;Cho, Sung-Min;Lee, Hee-Tae;Jang, Sung-Kyu;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.131-137
    • /
    • 2010
  • Change of the energy used in a house can be separated from LNG, and electric power. The electric power consumption of a house is more increasing than LNG. The interest for electric houses is rising due to energy saving and low carbon emission. Accordingly, the amount of energies and cost are analyzed consumed in a house using cumulative energy consumption. The result of analysis, amount of electric power, is more increase. In comparison, the use volume of city gas is more decrease. In this paper, the use volume of energy resource is analyzed using historical energy consumption data in the past 25 years. In addition, expected electrical power and heating energy is analysed adopting an Electric Residence.

Optimization of Lace Tube with Gray Theory and Design of Experiment (회색 관계 이론과 실험계획을 이용한 Lance Tube Nozzle 최적화)

  • Jeong, Ilkab;Lee, Dongmyung;Lee, Sangbeom;Lim, Jintaek
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1001-1006
    • /
    • 2016
  • As consumption of energy is increasing rapidly, energy saving is emphasized in nowadays. Thermal power plant occupies a large proportion in various type of power plant. Major causes of decreased power generation efficiency on thermal power stations is deposition of fly ash. Soot Blower is a facility to remove the ash which is deposited outside of tube by steam blowing on boiler. Residual stream which caused by lance tube in soot blower cannot be discharged steam effectively in lance tube causes reducing the thickness of lance tube. On the contrary, increasing discharge ratio of steam, lance tube cannot sustain proper pressure to remove ash on tube. This study suggests increasing discharge ratio of steam with proper pressure to remove ash on tube by optimization on shape of lance tube nozzle. To optimize shape of nozzle, discharge ratio and maximum blowing pressure on nozzle is selected as object functions. Diameter of nozzle, distance between nozzles, angle of nozzle and gap between nozzle is selected as design parameters. Then the design of experiment (DOE) with an orthogonal array is performed to analyze the effect of design parameters. And grey relational analysis and analysis of mean (ANOM) is performed to optimize shape of lance tube.

Numerical Analysis of the Energy-Saving Tray Absorber of Flue-Gas Desulfurization Systems (배연탈황설비의 에너지 절약형 트레이 흡수탑에 대한 수치 해석적 연구)

  • Hwang, Jae-Min;Choi, Ssang-Suk;Chung, Jin-Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.8
    • /
    • pp.775-782
    • /
    • 2010
  • This study is performed to study the effect of the tray in the absorber of a flue-gas desulphurization (FGD) system by using a computational fluid dynamic (CFD) technique. Stagnant time of slurry and the pressure drop in the FGD absorber increase when a tray is used in the absorber. Stagnant time of slurry results in an increase in the desulfurization effect and a decrease in the power of the absorber recirculation pump; however, increased pressure drop requires more power of booster fan in the FGD system should be increased. The gas and slurry hydrodynamics inside the absorber is simulated using a commercial CFD code. The continuous gas phase has been modeled in an Eulerian framework, while the discrete liquid phase has been modeled by adopting a Lagrangian approach by tracking a large number of particles through the computational domain. It was observed that the power saved upon increasing the stagnant time of slurry was more than increased power with pressure drop.

Improving of propulsion performance of 24 ton class squid jigging vessel (오징어 채낚기 어선의 추진기 개선을 통한 성능향상)

  • JEONG, Seong-Jae;AHN, Heui-Chun;KIM, In-Ok;CHA, Bong-Jin;KOO, Myung-Sung;LEE, Kyounghoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.4
    • /
    • pp.347-355
    • /
    • 2016
  • In this study, a new designed propeller was applied on 24 ton class squid jigging vessel to reduce of fuel consumption. The selected squid jigging boat was under construction at the shipyard to determine the resistance of the hull through the model experiment. The propeller design was carried out by using the experimental data and ITTC procedures. Sea trials were performed by measuring the speed and the horsepower required by the condition of five power levels of engine load, namely 70%, 80%, 90%, MCR and maximum engine power. The speed and delivered horse power were compared between the conventional propeller and the new design propeller. Delivered horse power by installing the new propeller takes 90% engine load at start-up conducted by decreased 9.06%. The measuring speed is increased up to the 0.6 knots in the low-speed range to high range. This study showed that only the design and installation of a new propeller can improve the propulsion efficiency of the boats; furthermore, reduce fuel costs can be achieved at the same time by improving the increased cruising speed.

Analysis of Temperature and Power Generation Characteristics of Bifacial BIPV System Applied into Curtain Wall (양면형 BIPV 시스템의 커튼월 적용에 따른 온도 및 발전특성 분석)

  • Kang, Jun-Gu;Kim, Yong-Jae;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.4
    • /
    • pp.57-66
    • /
    • 2015
  • BIPV system not only produces electricity at building, but also acts as a material for building envelope. Thus, it can increase the economical efficiency of PV system by saving the cost for building materials. Bifacial solar cell can convert solar energy to electrical energy from both sides of the cell. In addition, it is designed as 3 busbar layout which is the same with ordinary mono-facial solar cells. Therefore, many of the module manufacturers can easily use the bifacial solar cells without changing their manufacturing equipments. Moreover, bifacial PV system has much potential in building application by utilizing glass-to-glass structure of PV module. However, the electrical generation of the bifacial PV module depends on the characteristics of the building surface which faces the module, as well as outdoor environment. Therefore, in order to apply the bifacial PV module to building envelope as BIPV system, its power generation characteristics are carefully evaluated. For this purpose this study focused on the electrical performance of the bifacial BIPV system through the comparative outdoor experiments. As a result, the power generation performance of the bifacial BIPV system was improved by up to 21% compared to that of the monofacial BIPV system. Therefore, it is claimed that the bifacial BIPV system can replace the conventional BIPV system to improve the PV power generation in buildings.

Analysis of Development Situation of Korean and Foreign Street Furnitures Using Alternative Energy (대체에너지를 이용한 국·내외 가로시설물 개발 유형 분석)

  • Kim, Ja Kyung;Park, Hyung Jin
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.33-44
    • /
    • 2010
  • These days, the use of alternative energy is recognized as one of countermeasures to rising oil prices and climate-change agreements. Especially, it is regarded as a main element to realize 'Low-Carbon Green Growth', one of the key policies of MB government. However, though alternative energy, renewable energy, is a main policy issue of the present administration, there are many problems to solve: the lack of recognition of its energy, the low level of its technology, its expert's shortage, and its limited application fields. Therefore, to stimulate the use of alternative energy in Korea and to change the recognition of this energy, it is needed to utilize it to urban street furniture that many people visit and use. In particular, if alternative energy is first applied to street furniture that needs energy for its management, the effect of publicity and energy saving will be so great. In this study, for the basic research to introduce and promote various alternative energy sources such as solar power, wind power, small hydro power, and human power, we analyzed the present condition of development of Korean and foreign street furniture items. Furthermore, we evaluated the level of development of these street furniture products and the design types of them and from these evaluations suggested the design direction that can solve problems in development and improve the possibility of application of these energy sources to these street furniture items. Through these analyses, this study aims to enhance the image of future environment-friendly city and make new index for the application of alternative energy.

Analysis of the Disaster Sites using Power-assisted Devices for Rescue (인명구조용 근력지원장치의 적용가능한 재난현장 분석)

  • Lee, Minsu;Park, Chan;Kim, Jingi;Lee, Dongeun
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.3
    • /
    • pp.273-278
    • /
    • 2016
  • In this study, we set the need, purpose, and the direction of developments in life-saving devices and analyzed the disaster sites where power-assisted devices are to be applied. For this purpose, we classified the disaster in accordance with the Basic Law for on Disaster and Safety Management and analyzed the common disaster sites where power-assisted devices are available. As a result, 13 disaster sites were classified into three categories. Firstly, 8 sites of social disaster accidents, fire(suppression), fire(rescue), collapse, traffic accidents, explosion, CBR(chemical, biological, and radiological), environment pollution, and other safety accidents, were defined. Secondly, 4 disaster accidents, earthquake, flood, typhoon and other natural disasters, were classified. Finally, other disaster sites were taken into account.