• Title/Summary/Keyword: Power transportation capacity

Search Result 80, Processing Time 0.021 seconds

A Study on the Urban Air Mobility(UAM) Operation Pilot Qualification System

  • Kim, Su-Ro;Cho, Young-Jin;Jeon, Seung-Mok
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.201-208
    • /
    • 2022
  • As around the world, ground and underground transportation capacity is reaching its limit, centering on urban areas. As urban traffic becomes congested, time and cost are astronomical, and environmental destruction caused by urban pollution is becoming increasingly serious. As a way to solve this problem, the means of flying over the air are in the spotlight as the next generation of future transportation, and the concept of urban air mobility (UAM, Urban Air Mobility) is defined as systematic planning. The development of an electric-powered vertical take-off (eVTOL) aircraft that obtains electric power through a battery using a personal aerial vehicle (PAV) as a means of transportation has accelerated. As the aircraft development of new technology aircraft in the evtol method is actively carried out, the need to prepare systems such as aircraft certification standards, pilot qualification systems, and qualification management is emerging. The Federal Aviation Administration (FAA) and the European Union Aviation Safety Agency (EASA), which lead international standards, announced new special technical conditions and temporary regulations SCVTOL-01, respectively. However, the pilot qualification system for operating the uam aircraft has not yet been clearly announced. Therefore, this paper analyzes the recently announced FAA regulations and EASA regulations to identify differences and directions in perspectives on UAMs and study the existing vertical take-off and landing aircraft (VTOL) pilot qualification system to present directions for qualification classification.

Improvement of System for Grain Drying, Storing , and Processing in Rural Area (농촌의 주곡 건조.저장.가공 작업체계 개선확립)

  • 서상용;이승규;김용환
    • Journal of Biosystems Engineering
    • /
    • v.3 no.1
    • /
    • pp.33-46
    • /
    • 1978
  • To get the goal of self-supply of food grain, improvement of post-harvest grain operations in rural area is under consideration as an important task of agriculture in Korea. This is study is focused on elimination of losses and deteriorations of grain and reduction of labour requirements and funds for post-harvest grain operations. The purpose of this study are presentation of basic data referring to conventional post-harvest grain operations in rural area and suggestion of improving methods for the operations, and also finding out reasonable operating processes of the operations. The result of this study are follows; 1. Grain drying in-the-filed which is performed before threshing has major factors of grain loss during drying, and so should be restrained as possible. Combine harvesting system is recommended among other king of mechanized harvesting systems for restraining in-the-field drying and securing available labors for drying. 2. It is predicted that mechanical grain drying could be prevalent when combine harvesting is taken place. Recommended grain drier for pre-combine harvesting system and for combine harvesting system is batch-type drier and circulating -type drier, respectively. 3. As existing farm storages for grain have insufficient spaces and offer poor conditions for grain storing , it is greatly needed to build up new storage which store only grains. And it is concluded that storing grain in community common storages in desirable. 4. Power supplying system for milling machinery in local milling plants, that a large capacity prime mover supplies power to 4 to 6 kinds of milling machinery simultaeously, should be converted to a system of several small capacity prime movers supplying power to each machiner y for the purpose of reducing extra consumption of energy. 5. Governmental grain, of which Korean farms produced, should be milled and stored in the local milling plant successively for the purpose of reducing transportation fee and stroing facilities. 6. Furture post-havest grain operations-drying, storing and milling should be periormed successively in he community common plant. And average optimum processing capacity of the plant is estimated about 300 metric ton of grain every year.

  • PDF

Thermal Characteristics Analysis of Upper Arm Hybrid Structure of Lightweight Pantograph Considering Heat Source by Collecting Current (집전전류에 의한 열원을 고려한 경량 판토그래프 상부암 혼성구조체의 열 특성 분석 연구)

  • Park, Chan-Bae;Jeong, Geochul
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.4
    • /
    • pp.466-473
    • /
    • 2017
  • Recently, domestic railway related institutes are developing pantographs for high speed trains; to lighten the upper arm, this device has a composite structure of CFRP (Carbon Fiber Reinforced Plastic) and aluminum instead of conventional steel. In the case of KTX-Sancheon, the pantograph must have a large current capacity because this system is of power-car type, supplying all necessary power for the train through a single pantograph. If the thickness of the pipe is arbitrarily increased in order to increase the current carrying capacity, without analyzing the thermal characteristics of the aluminum pipe, the increase in the weight of the upper arm may cause degradation of the current collecting performance. Therefore, in this paper, using the thermal analysis technique, we analyze the temperature change characteristics of the aluminum pipe of the upper arm over time, while receiving power at the stationary state of the KTX-Sancheon; we also examine the adequacy of the minimum thickness of the aluminum pipe in accordance with the proposed pantograph flow capacity.

A wireless monitoring system for monocrystalline PV system

  • Kelebekler, Ersoy;Ergun, Riza Emre
    • Advances in Energy Research
    • /
    • v.7 no.2
    • /
    • pp.123-134
    • /
    • 2020
  • Photovoltaic systems are progressively attached importance and their installed capacity increases day by day because of their reliability, decremented installation and operating cost and simple construction structure. Generated power obtained from a photovoltaic system changes depending upon regional distinctness, and It can be estimated approximately by taking into consideration mean global radiation amount, temperature and humidity. However, there may be different regional negative or positive factors like dust, air pollution, desert powder which affect generated power. The best reliable data for a region can be obtained from the existing photovoltaic system in the region. For this purpose, a monitoring system for 1000W monocrystalline photovoltaic system constructed at Kocaeli University Uzunciftlik Nuh Cimento Vocational High Scholl is prepared. The installed monitoring system shows and records real values generated from the photovoltaic system and environmental data. In the study, Instantaneous data obtained from the monitoring system for October 2018 and 7th October 2018 is given within figures. Additionally, daily and monthly total energy productions of the photovoltaic system are given for October 2018 and date interval between July 2018 and March 2018, respectively.

A Study on Technology Development of High Capacity PWM Converter for Electric Vehicle (전기철도용 대용량 PWM 컨버터 기술개발에 관한 연구)

  • Han, Young-Jae;Jo, Jeong-Min;Bae, Chang-Han;Lee, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1729-1734
    • /
    • 2018
  • Recently, interest in environmentally friendly transportation systems has been increasing, and study on railway systems has been aggressively conducted. Therefore, lots of studies have been done in railway advanced countries to improve performance of PWM converter. The research on the PWM converter for railway vehicle was mainly carried out on the converter mounted on railway vehicle such as the high-speed railway and metropolitan railway. In also, a lot of study has been carried out to improve converter performance installed in the ground. The high-capacity transform used in this paper converted from AC 22.9kV to AC 590V. The converter changed from AC 590V to DC 950V. In general, in the case of rectifier, the DC power supply system has a negative impact on inverter control characteristics because it can not avoid the pulsating component. In this study, it was performed current control for high-capacity converter using Matlab Simulink. The PWM converter is normally performed through the voltage and current at starting mode, powering mode, and braking mode. In the light-load test and the on-line test, we have studied for the PWM converter characteristics. Using this research, we have founded that the converter has excellent performance.

Flexural bearing capacity and stiffness research on CFRP sheet strengthened existing reinforced concrete poles with corroded connectors

  • Chen, Zongping;Song, Chunmei;Li, Shengxin;Zhou, Ji
    • Structural Monitoring and Maintenance
    • /
    • v.9 no.1
    • /
    • pp.29-42
    • /
    • 2022
  • In mountainous areas of China, concrete poles with connectors are widely employed in power transmission due to its convenience of manufacture and transportation. The bearing capacity of the poles must have degenerated over time, and most of the steel connectors have been corroded. Carbon fiber reinforced polymer (CFRP) offers a durable, light-weight alternative in strengthening those poles that have served for many years. In this paper, the bearing capacity and failure mechanism of CFRP sheet strengthened existing reinforced concrete poles with corrosion steel connectors were investigated. Four poles were selected to conduct flexural capacity test. Two poles were strengthened by single-layer longitudinal CFRP sheet, one pole was strengthened by double-layer longitudinal CFRP sheets and the last specimen was not strengthened. Results indicate that the failure is mainly bond failure between concrete and the external CFRP sheet, and the specimens fail in a brittle pattern. The cross-sectional strains of specimens approximately follow the plane section assumption in the early stage of loading, but the strain in the tensile zone no longer conforms to this assumption when the load approaches the failure load. Also, bearing capacity and stiffness of the strengthened specimens are much larger than those without CFRP sheet. The bearing capacity, initial stiffness and elastic-plastic stiffness of specimen strengthened by double-layer CFRP are larger than those strengthened by single-layer CFRP. Weighting the cost-effective effect, it is more economical and reasonable to strengthen with single-layer CFRP sheet. The results can provide a reference to the same type of poles for strengthening design.

ANALYSIS OF THE TRANSPORTATION LOGISTICS FOR SPENT NUCLEAR FUEL IN KOREA

  • Lee, Hyo-Jik;Ko, Won-Il;Seo, Ki-Seok
    • Nuclear Engineering and Technology
    • /
    • v.42 no.5
    • /
    • pp.582-589
    • /
    • 2010
  • As a part of the back-end fuel cycle, transportation of spent nuclear fuel (SNF) from nuclear power plants (NPPs) to a fuel storage facility is very important in establishing a nuclear fuel cycle. In Korea, the accumulated amount of SNF in the NPP pools is troublesome since the temporary storage facilities at these NPP pools are expected to be full of SNF within ten years. Therefore, Korea cannot help but plan for the construction of an interim storage facility to solve this problem in the near future. Especially, a decision on several factors, such as where the interim storage facility should be located, how many casks a transport ship can carry at a time and how many casks are initially required, affect the configuration of the transportation system. In order to analyze the various possible candidate scenarios, we assumed four cases for the interim storage facility location, three cases for the load capacity that a transport ship can carry and two cases for the total amount of casks used for transportation. First, this study considered the currently accumulated amount of SNF in Korea, and the amount of SNF generated from NPPs until all NPPs are shut down. Then, how much SNF per year must be transported from the NPPs to an interim storage facility was calculated during an assumed transportation period. Second, 24 candidate transportation scenarios were constructed by a combination of the decision factors. To construct viable yearly transportation schedules for the selected 24 scenarios, we created a spreadsheet program named TranScenario, which was developed by using MS EXCEL. TranScenario can help schedulers input shipping routes and allocate transportation casks. Also, TranScenario provides information on the cask distribution in the NPPs and in the interim storage facility automatically, by displaying it in real time according to the shipping routes, cask types and cask numbers that the user generates. Once a yearly transportation schedule is established, TranScenario provides some statistical information, such as the voyage time, the availability of the interim storage facility, the number of transported casks sent from the NPPs, and the number of transported casks received at the interim storage facility. By using this information, users can verify and validate a yearly transportation schedule. In this way, the 24 candidate scenarios could be constructed easily. Finally, these 24 scenarios were compared in terms of their operation cost.

A Study on Energy Usage Monitoring and Saving Method in the Sewage Treatment Plant (공공하수처리시설에서 에너지 사용현황 및 절감방안 연구)

  • Kim, Jongrack;Rhee, Gahee;You, Kwangtae;Kim, Dongyoun;Lee, Hosik
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.535-545
    • /
    • 2020
  • This study aims to conserve and monitor energy use in public sewage treatment plants by utilizing data from the SCADA system and by controlling the aeration rate required for maintaining effluent water quality. Power consumption in the sewage treatment process was predicted using the equipment's uptime, efficiency, and inherent power consumption. The predicted energy consumption was calibrated by measured data. Additionally, energy efficiency indicators were proposed based on statistical data for energy use, capacity, and effluent quality. In one case study, a sewage treatment plant operated via the SBR process used ~30% of energy consumed in maintaining the bioreactors and treated water tanks (included decanting pump and cleaning systems). Energy consumption analysis with the K-ECO Tool-kit was conducted for unit processing. The results showed that about 58.7% of total energy consumed was used in the preliminary and biological treatment rotating equipment such as the blower and pump. In addition, the energy consumption rate was higher to the order of 19.2% in the phosphorus removal process, 16.0% during sludge treatment, and 6.1% during disinfection and discharge. In terms of equipment energy usage, feeding and decanting pumps accounted for 40% of total energy consumed following 27% for blowers. By controlling the aeration rate based on the proposed feedback control system, the DO concentration was reduced by 56% compared pre-controls and the aeration amount decreased by 28%. The overall power consumption of the plant was reduced by 6% via aeration control.

Antioxidant Activities of Extracts from Different Parts of the Pine Tree (소나무 부위별 추출물의 항산화 활성)

  • Ryu, Beom-Seok;Choi, Hee-Eun;Choi, Won-Seok;Lee, Nan-Hee;Choi, Ung-Kyu
    • The Korean Journal of Food And Nutrition
    • /
    • v.30 no.6
    • /
    • pp.1133-1139
    • /
    • 2017
  • This study was conducted to investigate the antioxidant activities of extracts from various parts of the pine tree, which is known as a good source of functional food material. While ethanol extraction yields of pine bud and cone were higher than water extraction yields of pine bud and cone, water extraction yield of pine needle was higher than ethanol extraction yield of the pine needle. The content of polyphenols in the pine cone ethanol extract was 5 times higher than that in the pine bud and needle. Further, the content of flavonoids in the pine cone ethanol extract was 8 times higher than that in the pine bud and needle. DPPH radical scavenging effect of the pine cone ethanol extract was 3~5 times higher that of the pine bud and needle extract. Regardless of the extraction solvents, trolox equivalent antioxidant capacity (TEAC) and ferric reducing antioxidant power (FRAP) of the pine cone were stronger than those of the other parts of the pine tree. Taken together, it can be expected that the pine cone can be practically used as an antioxidant substance in food and beauty industries.

Optimal Design of Urban MICROGRID using Economical Analysis Program (경제성분석 프로그램을 이용한 도심형 마이크로그리드 최적 설계)

  • Seung-Duck, Yu;SungWoo, Yim;Youseok, Lim;SungWook, Hwang;JuHak, Lee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.69-72
    • /
    • 2022
  • This paper actually investigates the load on major large-scale buildings in the downtown area, examines the economic feasibility of installing PV and ESS in a microgrid target building, and evaluates whether an electric vehicle capable of V2G through two buildings is effective as an economical analysis program (HOMER) was analyzed using. It is economical to install a mixture of ESS rather than using the whole PV, and it is shown that if there is an electric vehicle using the V2G function of EV, there is an economic effect to replace the PV. So that Incentives and policies are needed to replace a large area of PV and utilize the existing parking lot to lead EV as a resource of the microgrid. Currently, P2X technology that stores power as ESS or converts it to other energy to control when surplus renewable energy occurs in large-capacity solar power plants and wind farms, etc. This is being applied, and efforts are being made to maintain the stability of the system through the management of surplus power, such as replacing thermal energy through a heat pump. Due to the increase in electric vehicles, which were recognized only as a means of transportation, technologies for using electric vehicles are developing. Accordingly, existing gas stations do not only supply traditional chemical fuels, but electricity, and super stations that also produce electricity have appeared. Super Station is a new concept power plant that can produce and store electricity using solar power, ESS, V2G, and P2G. To take advantage of this, research on an urban microgrid that forms an independent system by tying a large building and several buildings together and supplies power through a super station around the microgrid is in full swing.