• Title/Summary/Keyword: Power transformers

Search Result 720, Processing Time 0.029 seconds

The Criteria and Results of the Power Transformer DGA (전력용 변압기 유중가스분석의 기준과 적용결과)

  • Cho, Sung-Min;Shin, Hee-Sang;Kim, Jae-Chul;Kweon, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.166-168
    • /
    • 2007
  • The DGA (Dissolved Gases Analysis) technique has been widely using for fault diagnosis of the power transformers. This technique has a high reliability than other techniques. KEPCO (Korea Electric Power Cooperation) has been using DGA technique since KEPCO established the criteria of DGA in 1985. In this paper, we introduce the DGA criteria of KEPCO and analyze the result of DGA. Also we introduce the cases of thoroughgoing inspection of the power transformers caused by DGA and compare the judgment of DGA with the result of throughgoing inspection.

  • PDF

A Study on the Diagnosis of Power Transformers by Analysis of Insulating Oil (절연유의 분석에 의한 변압기 진단에 관한 연구)

  • Kim, Kyeongsook;Lim, Chunsik;Park, Hyunjoo;Lee, Taewon;Yang, Seungran
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.166-172
    • /
    • 2000
  • The life expectation of power transformers is basically dependent on the aging deterioration of insulating paper which can not be obtained from operating transformers. Therefore, it will be very useful if we can manage transformers by indirect analysis of degradation products. "Furan derivatives" are known the decomposition products which are generated by the degradation of cellulose in insulating paper. We proved that 2-furfural is the only measurable product from our transformers, and determined easily the concentration of 2-furfural by HPLC without any specific pretreatments, Compared to concentration of $CO_2$ and CO by GC, the concentration of 2-furfural by HPLC can estimate more accurately aging characteristics of transformers. We expect that these results can be utilized to predict the aging characteristics and life diagnosis of power transformers.

  • PDF

Development of Diagnostic Algorithm and Expert System to diagnose Power Transformers by the methods of Gas Analysis (가스분석기법을 이용한 전력용 변압기 내부 이상진단을 위한 진단 알고리즘 및 전문가시스템 개발)

  • 최인혁;정길조;권동진;신명철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.68-74
    • /
    • 2001
  • This paper describes the new algorithm method for detecting abnormal causes within power transformers. Generally, the gas analysis has been proved the most confident method of many transformer diagnostics. The proposed algorithm is adapted to the international codes of IEC, Dornenburg, Gas Pattern including the DEPCO´s gas analysis method for the improvement of diagnostic efficiency. Specially, this algorithm is programmed by the tool of Element Expert developed Neuron DATA Inc. in USA. Also, it was confirmed that the developed algorithm is proved the confidence by the use of real data in fault power transformers.

  • PDF

Selection of Transformer for the Augmentation of an Existing AIS EHV Substation in Hilly Terrain at 3000m+ Altitude

  • Kim, Kwang-Soo;Kang, Byoung-Wook;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.28-36
    • /
    • 2012
  • Augmentation of existing EHV substations located in hilly terrain and at high altitude require many different considerations as compared to substations located in plain areas and at lower altitude. Owing to high altitude and steep terrain, meticulous engineering and preparations are required, considering the actual available space at the existing substation. Historical fault events too must be considered to enhance reliability and performance of the substation equipment. This paper proposes ways to augment the existing 2 banks of 20MVA, 220/66kV power transformers ($3{\times}6.67MVA$, single-phase) to $2{\times}50$/63MVA, 220/66kV power transformers to meet continuously increasing demand of the capital city over the next 20 years. Upgrading and augmentation of existing substations, especially the main transformers and associated equipment, require replacement with minimum or no disturbance to the existing power supply system. Considerations should also be made during engineering and design, the operational flexibilities, maintenance aspects, future expandability and value addition, in terms of reliability and space usage of the existing substation.

Isolated Multi-level Inverter Using 3-Phase Transformers (3상 변압기를 이용한 절연형 멀티레벨 인버터)

  • Kim, Tae-Jin;Park, Sung-Jun;Kim, Cheul-U;Song, Sung-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.139-148
    • /
    • 2007
  • In this paper, we proposed the isolated multi-level inverter using 3-phase transformers. It makes possible to use a single DC power source due to employing low frequency transformers. In this inverter, the number of transformer could be reduced comparing with an exiting 3-phase multi-level inverter using single phase transformer. Also, using phase angle control method with switching frequency equal to output fundamental frequency, harmonics component of output voltage and switching losses can be reduced. Finally, we made a prototype inverter to clarify the proposed electric circuit and reasonableness of control signal.

Power Loss Calculation of High Frequency Transformers

  • Choi Geun-Soo;Yoon Shin-Yong;Baek Soo-Hyun;Kim Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.338-342
    • /
    • 2006
  • This paper analyzed the power loss of transformers considering the magnetic component. For this, each winding strategy and the effect of air gap between the ferrite core have been an important variable for optimal parameter calculation. Inductors are very well known design rules to devise, but the performance of the flyback converter as a function of transformer winding strategy has not been fully developed. The transformer analysis tool used was PExpert. The influence of the insulator thickness, effect of the air gap, how the window height and variation of the capacitive value effects the coil and insulator materials are some of parameters that have been analyzed in this work. The parameter analysis is calculated to a high frequency of 48[kHz]. Therefore, the final goal of this paper was to calculate and adjust the parameters according to the method of winding array and air gap minimizing the power loss.

The investigation of field condition on flood protection of substation and underground power equipment (pad-mounted transformers & switches) (수변전실 및 지중 배전기기의 침수 방지 관련 현장 조사 분석)

  • Kim, Gi-Hyun;Choi, Myeong-Il;Bae, Suk-Myong;Lee, Jae-Yong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.327-331
    • /
    • 2007
  • Inundation of substation and underground power equipment(pad-mounted transformers & switches) breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. In case inundation of substation and underground power equipment, it occurs a great economic loss owing to recovery time and events of electric shock occur by inundation electrical facility. So we search the damage situation and installation situations. Therefore we propose the necessity of protection of flood at low-lying downtown and low-tying shore. This paper will be used to present a reform proposal of electrical related law about flood protection of existing power equipment.

  • PDF

Expert System for Fault Diagnosis of Transformer

  • Kim, Jae-Chul;Jeon, Hee-Jong;Kong, Seong-Gon;Yoon, Yong-Han;Choi, Do-Hyuk;Jeon, Young-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.7 no.1
    • /
    • pp.45-53
    • /
    • 1997
  • This paper presents hybrid expert system for diagnosis of electric power transformer faults. The expert system diagnose and detect faults in oil-filled power transformers based on dissolved gas analysis. As the preprocessing stage, fuzzy information theory is used to manage the uncertainty in transformer fault diagnosis using dissolved gas analysis. The Kohonen neural network takes the interim results by applying fuzzy informations theory as inputs, and performs the transformer fault diagnosis. The Proposed system tested gas records of power transformers from Korea Electric Power Corporation to verify the diagnosis performance of transformer faults.

  • PDF

The effectiveness of noise reduction devices for transformer noise control of Power Plants (발전소 변압기 소음저감 대책의 유효성)

  • Kim, Yeon-Whan;Kim, Hee-Soo;Bae, Yong-Chae;Lee, Hyun;Kim, Sung-Hwi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1823-1828
    • /
    • 2000
  • Power transformers, air-intakes, stacks in a combined thermal power plant are the main noise sources. Power transformer noise among them has being get a target of public complaint due to 480Hz component of its pure tone. The source is mainly magnetostrictive vibration of the transformer core. The first countermeasures was installing sound barrier on the front of transformer. However, 500Hz, center of the frequency is not reduced. This paper includes the measurements of noise level at the near resident apartment, the identification of noise transfer and the countermeasures for noise sources. Cavity resonance type of noise reduction devices was installed on enclosuring wall of transformers. As a result, the noise level from transformer is reduced about 3dB.

  • PDF

Uniform Current Distribution among Conductor Layers in HTS Cables Using Inter-Phase Transformers (Inter-Phase Transformers를 이용한 고온 초전도 케이블의 층간 전류 등분배 방안)

  • 최용선;황시돌;현옥배;임성우;박인규
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.144-148
    • /
    • 2004
  • Uniform current distribution among conductor layers in HTS cables using IPTs (inter-phase transformers) was investigated. Conventional methods for current distribution, in which resistors are inserted to conductor layers, causes additional loss. In contrast, IPTs, which use magnetic coupling, make it possible that the current in parallel circuits is distributed uniformly with any load, and minimize the loss. In this study, IPTs were designed and fabricated for examination of uniform current distribution in the conductor layers of HTS cables. The ITP was designed through calculation of its impedance that can cancel the inductance of the conduction layers. The experimental setup consisted of four IPTs and four inductors that simulate the conductor layer inductance. Each layer was designed to feed 10 A. We examined the behavior of current distribution with IPTs for various layer inductances.

  • PDF