• 제목/요약/키워드: Power transformer

검색결과 2,517건 처리시간 0.022초

변압기철손 측정시스템의 측정 불확도 (Review of the measurement uncertainty of Tr no-load loss measuring system)

  • 강택수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.139-141
    • /
    • 2005
  • For the reliable evaluation of the distribution and power transformer no-load loss measurement, measurement uncertainty of the transformer measuring system, consisted of current transformer, potential transformer and power metering equipment is required. In this paper, we describe the uncertainty of transformer measuring system based on ANSI/IEEE C57.12.90.

  • PDF

전력용변압기 유지보수와 예방진단에 관한 소고 (A study for power transformer maintenance and preventive diagnostics)

  • 김동현;이옥배;주병수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.915-918
    • /
    • 2000
  • This paper presents the maintenamce method of transmission power transformer by Korea Electric Power Corporation. Also, this paper presents preventive diagnostics method for power transformer and introduce the new preventive diagnostics method for power transformer.

  • PDF

콘덴서 제어회로를 이용한 배전용 변압기의 역률 개선에 관한 연구 (A Study for Improving the Power Factor of Distribution Transformer using Condenser Control Circuit)

  • 이광직
    • 조명전기설비학회논문지
    • /
    • 제28권4호
    • /
    • pp.21-28
    • /
    • 2014
  • Daily use characteristics of apparent power supplied to distribution transformer can be separated into two different time zone of waking hours and sleeping hours. In sleeping hours, using amount of power is decreasing. The actual curve of power seemed to be quite similar to this kind of separation. Inserting a condenser into a circuit in each different time zone led to maximize power factor of the transformer. The compensating condenser's on/off time is controlled by hysteresis circuit utilizing op amp and power factor of the transformer was improved from 0.945 to 0.999. As a result, the average of current reduction was 2.53A per hour of transformer.

Intuitionistic Fuzzy Expert System based Fault Diagnosis using Dissolved Gas Analysis for Power Transformer

  • Mani, Geetha;Jerome, Jovitha
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2058-2064
    • /
    • 2014
  • In transformer fault diagnosis, dissolved gas analysis (DGA) is been widely employed for a long period and numerous methods have been innovated to interpret its results. Still in some cases it fails to identify the corresponding faults. Due to the limitation of training data and non-linearity, the estimation of key-gas ratio in the transformer oil becomes more complicated. This paper presents Intuitionistic Fuzzy expert System (IFS) to diagnose several faults in a transformer. This revised approach is well suitable to diagnosis the transformer faults and the corresponding action to be taken. The proposed method is applied to an independent data of different power transformers and various case studies of historic trends of transformer units. It has been proved to be a very advantageous tool for transformer diagnosis and upkeep planning. This method has been successfully used to identify the type of fault developing within a transformer even if there is conflict in the results of AI technique applied to DGA data.

단상 NPC Module- 3직렬 Cascade 구성 방식의 75KVA급 단상 지능형 변압기 개발 (Single Phase NPC Module - Development of 75KVA Single Phase Smart Transformer with 3 Serial Cascade Configuration)

  • 박주영;니이테게카;조경식;김명룡;박가우
    • 전력전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.118-125
    • /
    • 2017
  • In this paper, we propose a smart transformer for a smart transformer miniature model, which can replace a 60 [Hz] single-phase transformer installed in an electric vehicle. The proposed smart transformer is lighter than a conventional transformer, can control instantaneous voltage, and can be expected to improve power quality through harmonic compensation. The proposed intelligent transformer consists of an incoming part, an AC/DC converter, and a dual active bridge. Only the incoming part and the AC/DC converter are described in this paper. The proposed intelligent transformer has 75 kVA 3.3 kV input and 750 V DC output, which are verified by simulation and experiment.

A Study on Novel Power Supply for Microwave Oven Using HVC Embedded High Frequency Transformer

  • Cho Jun-Seok;Park Kang-Hee;Jeong Byung-Hwan;Mok Hyung-Soo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.581-585
    • /
    • 2001
  • This paper describes novel high voltage capacitor(HVC) embedded high frequency transformer and novel inverter power supply topology for driving magnetron in microwave oven. This transformer is used to achieve down­sizing, low-cost and efficiency improvement. Proposed transformer has HVC in its secondary winding. Therefore, this transformer does not need external high voltage capacitor which used in conventional power supply. As use of this transformer, output voltage is shifted from ground to above 2000[V] and efficiency of microwave oven can be improved. The weight of proposed transformer is about one sixth of conventional one and efficiency is improved by seven percent compared to the efficiency of the conventional system.

  • PDF

웨이블렛 변환을 이용한 변압기 보호계전 알고리즘 (Protective Relaying Algorithm for Transformer Using Wavelet Transform)

  • 홍동석;이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권2호
    • /
    • pp.134-141
    • /
    • 2003
  • The power transformer is one of the very important electric facilities in power systems. Recently, current differential relay is widely used to protect such power transformer But if inrush occurs in transformer, relay can be tripped by judging like internal fault. Therefore the correct discrimination between internal winding fault, inrush and overexcitation should be performed. This paper presents a new protective relaying algorithm which discriminates inrush, internal faults and overexcitation of transformer modelled using BCTRAN and HYSDAT of EMTP. Discrimination between internal winding fault and inrush is revealed in simulation within 1/2 cycle after fault. Accordingly, it is evaluated that the proposed algorithm has better discrimination characteristics in various cases thin the current relaying for protection of transformer.

절연유 내 변압기 Turn간 결함에 의한 부분방전의 극초단파 전자기파 신호 특성 (Characteristics of Ultra High Frequency Partial Discharge Signals of Turn to Turn Defect in Transformer Oil)

  • 윤진열;주형준;구선근;박기준
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.2000-2004
    • /
    • 2009
  • In general, for the condition monitoring of a power transformer using the UHF PD measuring technique, detection of any partial discharge, identifying the defect in the transformer and locating the insulation defect are necessary. In this paper one of the most frequent detects which can result in turn to turn fault in power transformer was examined for identifying the defect. In order to model the defect, as a discharge source, a partial discharge cell was used for experimental activity. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and phase resolved partial discharge signals were measured and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the occurrence of transformer faults.

배전용 변압기의 실시간 고조파 분석 알고리즘 개발 (The Development of Real-Time Harmonic Analysis Algorithm in Distribution Transformer)

  • 박철우
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.43-49
    • /
    • 2013
  • Recently harmonics flowing into power system is increasing as the usage of semiconductor equipments and switching mode power equipments are increasing. Harmonics cause problems such as heat increasing and reduction in capacity of transformers, especially the harmonics flowing into a distribution transformer can lead to the lifetime reduction of transformer. In this paper, we are about to develop a device that can monitor harmonics in real-time as it is affixed to a distribution transformer. Unlike the existing expensive harmonic analysis device, a new harmonic analysis algorithm is proposed in order to implement low-cost equipment. The real-time harmonic analysis algorithm proposed in this paper allows implementation on low performance microcontrollers, thus it can monitor the harmonic in real-time as it is individually affixed to the transformer. Therefore, it would improve the reliability of the transformer and stable power system operation would be possible as it can prevent the transformer accidents in advance.

하수처리장 변압기 설치사례 연구를 통한 전력손실 저감방안 (Case Studies on the Electric Power Loss Reducing Methodology for Transformer Installation in Sewage Treatment Plant)

  • 김주영;최창규
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.70-77
    • /
    • 2011
  • Sewage treatment plants, consuming 1,756[GWh] which is 0.53[%] of national wide electricity consumption, is one of the electricity consuming facilites. At the research of electricity consumption and power quality analysis on sewage treatment plants, average utilization of transformer was less than 40[%] because peak load was very lower than its capacity due to excess capacity. So reduction of power loss can be achieved by transformer design optimization. The achievement in this research, is to meet reduction of power loss through optimizing the capacity and to improve as high efficiency-low loss transformer while the transformer is operating.