• Title/Summary/Keyword: Power system reliability evaluation

Search Result 352, Processing Time 0.026 seconds

LOLE(Loss of Load Expctatiom) Evaluation using Fuzzy Set Theory (퍼지 집합 이론을 이용한 공급지장 기대치의 산정)

  • 심재홍;정현수;김진오
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.9
    • /
    • pp.1055-1063
    • /
    • 1999
  • This paper present a conceptual possibilistic approach using fuzzy set theory to manage the uncertainties in the given reliability input date of the practical power system. In this paper, an algorithm is introduced to calculate the possibilstic reliability indices according to the degree of uncertainty in the given data. The probability distribution function can be transformed into an appropriate possibilstic representation using the probability-Possibility Consistency principle(PPCP) algorithm. In this the algorithm, the transformation is performation by making a compromise between the transformation consistency and the human updating experience. Fuzzy classifcation theory is applied to reduced the number of load data. The fuzzy classification method determines the closeness of load data points by assigning them to various clusters and then determening the distance between the clusters. The IEEE-RTS with 32-generating units is used to demonstrate the capability of the proposed algorithm.

  • PDF

A Study on the Outage Cost Assessment by using Macro Approach (거시적인 접근방법을 통한 공급지장비 추정에 관한 연구)

  • Park, Young-Shin;Jeon, Dong-Hoon;Park, Jeong-Je;Oh, Tae-Gon;Cho, Kyeong-Hee;Choi, Jae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1703-1711
    • /
    • 2010
  • Electric power utilities are facing increasing uncertainties regarding the economic, political, societal, environmental constraints under they operate and plan their future systems. The utilities have to integrate consumers' interruption cost representing reliability worth of electricity into the process of determining the optimum investment level. In order to do so, the estimated outage cost must be included into quantitative index corresponding to system capital and operation investment cost to establish an optimal expansion plan. This paper is a study on the outage cost assessment by using macro approach for calculating IEAR(Interrupted Energy Assessment Rates) and the TRELSS(Transmission Reliability Evaluation for Large-Scale Systems) program was used to calculate EENS(Expected Energy Not Served).

Evaluation of Reliability Indices for Power Systems using Genetic Algorithm and Complex Method (유전알고리즘과 Complex Method를 이용한 전력시스템의 신뢰도 지수 산정)

  • 유현호;김진오
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.583-591
    • /
    • 1999
  • this paper proposes a new approach for calculating the reliability indices of generation system, such as interruption frequency and duration, by using the moment matching technique Two separate expressions are derived, one for the loss of load expectation(LOLE) and the other for the loss of load frequency (LOLF). These expressions are combination of exponentials and are therefore easily integrable and can be readily evaluated. In this paper, the parameters of the distribution functions of the LOLE and LOLF are evaluated by using Genetic Algorithm and Complex Method, and the proposed approach is quite comparable with the other methods at the aspect of accuracy and efficiency.

  • PDF

Optical coupling coefficients and packaging of optical transmitter module for optical subscriber (광가입자용 수동광정렬형 광송신 모듈에 대한 광결합 효율 및 패키징)

  • 김상곤;송민규
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.3
    • /
    • pp.179-186
    • /
    • 2000
  • Optical coupling coefficients and misalignment tolerance of 155 Mbps optical transmitter module of passive alignment technology, to be usable in ATM system, B-NT (Broadband Network Termination) system, and 10 G transmission system for information super-highway networks, were calculated, compaired with it's engineer samples, and discussed. These engineer samples of -4.5 dBm maximum output power were packaged in the method of butt coupling of flat-fiber and tested reliability evaluation. Hence the cheap packaging method of optical transmitter module was researched. rched.

  • PDF

Development of a Computer Code for Low-and Intermediate-Level Radioactive Waste Disposal Safety Assessment

  • Park, J.W.;Kim, C.L.;Lee, E.Y.;Lee, Y.M.;Kang, C.H.;Zhou, W.;Kozak, M.W.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.1
    • /
    • pp.41-48
    • /
    • 2004
  • A safety assessment code, called SAGE (Safety Assessment Groundwater Evaluation), has been developed to describe post-closure radionuclide releases and potential radiological doses for low- and intermediate-level radioactive waste (LILW) disposal in an engineered vault facility in Korea. The conceptual model implemented in the code is focused on the release of radionuclide from a gradually degrading engineered barrier system to an underlying unsaturated zone, thence to a saturated groundwater zone. The radionuclide transport equations are solved by spatially discretizing the disposal system into a series of compartments. Mass transfer between compartments is by diffusion/dispersion and advection. In all compartments, radionuclides ate decayed either as a single-member chain or as multi-member chains. The biosphere is represented as a set of steady-state, radionuclide-specific pathway dose conversion factors that are multiplied by the appropriate release rate from the far field for each pathway. The code has the capability to treat input parameters either deterministically or probabilistically. Parameter input is achieved through a user-friendly Graphical User Interface. An application is presented, which is compared against safety assessment results from the other computer codes, to benchmark the reliability of system-level conceptual modeling of the code.

Development of a New Numerical Analysis Method for Nodal Probabilistic Production Cost Simulation (각 부하지점별 확률론적 발전비용 산정을 위한 수치해석적 방법의 개발)

  • Kim, Hong-Sik;Mun, Seung-Pil;Choe, Jae-Seok;No, Dae-Seok;Cha, Jun-Min
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.9
    • /
    • pp.431-439
    • /
    • 2001
  • This Paper illustrates a new numerical analysis method using a nodal effective load model for nodal probabilistic production cost simulation of the load point in a composite power system. The new effective load model includes capacities and uncertainties of generators as well as transmission lines. The CMELDC(composite power system effective load duration curve) based on the new effective load model at HLll(Hierarchical Level H) has been developed also. The CMELDC can be obtained from convolution integral processing of the outage capacity probabilistic distribution function of the fictitious generator and the original load duration curve given at the load point. It is expected that the new model for the CMELDC proposed in this study will provide some solutions to many problems based on nodal and decentralized operation and control of an electric power systems under competition environment in future. The CMELDC based on the new model at HLll will extend the application areas of nodal probabilistic production cost simulation, outage cost assessment and reliability evaluation etc. at load points. The characteristics and effectiveness of this new model are illustrated by a case study of MRBTS(Modified Roy Billinton Test System).

  • PDF

Motion planning of a steam generator mobile tube-inspection robot

  • Xu, Biying;Li, Ge;Zhang, Kuan;Cai, Hegao;Zhao, Jie;Fan, Jizhuang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1374-1381
    • /
    • 2022
  • Under the influence of nuclear radiation, the reliability of steam generators (SGs) is an important factor in the efficiency and safety of nuclear power plant (NPP) reactors. Motion planning that remotely manipulates an SG mobile tube-inspection robot to inspect SG heat transfer tubes is the mainstream trend of NPP robot development. To achieve motion planning, conditional traversal is usually used for base position optimization, and then the A* algorithm is used for path planning. However, the proposed approach requires considerable processing time and has a single expansion during path planning and plan paths with many turns, which decreases the working speed of the robot. Therefore, to reduce the calculation time and improve the efficiency of motion planning, modifications such as the matrix method, improved parent node, turning cost, and improved expanded node were proposed in this study. We also present a comprehensive evaluation index to evaluate the performance of the improved algorithm. We validated the efficiency of the proposed method by planning on a tube sheet with square-type tube arrays and experimenting with Model SG.

Safety Review Experience of Computerized Logic System for YGN 3 and 4

  • Yun, Won-Young;Kim, Dae-Il;Koh, Jong-Soo;Kim, Bok-Ryul;Oh, Sung-Hun;Lim, Jang-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.602-607
    • /
    • 1995
  • This article presents safety review experience of microprocessor-based Interposing Logic System(ILS) of Engineering Safety Feature Actuation System(ESFAS). The ILS is the first application of computerized logic design to safety system in Korean nuclear power plants without verification of the system reliability by proven technology concept. As a result of evaluation for the ILS, Korea Institute of Nuclear Safety(KINS) concluded that the microprocessor-based ILS is not acceptable in some features detailed enough to defend against software common mode failures(CMF). Therefore, we required licensee to install hardwired interlock signal configuration and a Hardwired Backup Panel to control safety-related equipment. We believe that the microprocessor-based ILS with the hardwired backup panel and inter-connection of interlock signal by hardwired configuration will improve the plant safety.

  • PDF

The Study on Reliability Improvement in Eddy Current Inspection by Signal Characteristic Optimization of Multi-coil Array Probe (다중센서 신호특성 최적화를 통한 와전류검사 신뢰성 개선연구)

  • Ahn, Y.S.;Gil, D.S.;Park, S.G.
    • Journal of Power System Engineering
    • /
    • v.14 no.2
    • /
    • pp.60-64
    • /
    • 2010
  • This paper introduces reliability improvement and time saving in eddy current inspection by signal characteristic optimization of multi-coil eddy current array probe. In the past, Multi-coil array probe and single probe were used for the gas turbine rotor surface inspection & defect evaluation. The multi-coil array probe was used for the broad area inspection. But the signal deviations among multi-coil array probe are maximum 28% in commercial probe. This differences were considered to impedance differences among coils, so it is very difficult to evaluate exact defect size. The signal deviations among multi-coil array probe are maximum 28% in commercial probe. So, single coil inspection was used for exact defect sizing. The purpose of this study is to improve signal deviations of multi-coil array probe. The introduced new technology can improves this deviation by adjusting input voltage in each coil. At first, apply same voltage in each coil and collect signal amplitude of each coil. And calculate new input voltage based on signal amplitude of each coil. If the signal amplitude deviation is within 5% among multi-coil array probe, the signal amplitude of multi-coil array probe is reliable. The proposed technology gives 2% signal deviation among multi-coil array probe. The proposed new technology gives reliability improvement and inspection time saving in eddy current inspection.

Evaluation of communication reliability of a test-bed networked to the home appliances with PLC modems for the Internet accessed home automation

  • Ahn, Nam-Ho;Chang, Tae-Gyu;Kim, Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.591-594
    • /
    • 2002
  • This paper presents a systematic method of probing channel characteristics and communication reliabilities of home power line communication network applied to the Internet accessed control of home appliances. The effects of the three performance deteriorating factors, i.e., additive noise, channel attenuation, and intersymbol interference, can be systematically measured by applying the channel probing waveform in the frequency range from 100㎑ to 450㎑. Probability of bit error is derived with the probed channel parameters of the signal attenuation, noise and signal-to-interference ratio read in the frequency domain. The agreement between the derived probability of bit ewer and the measured probability of bit error support the validity of the proposed approach of probing home power line channel characteristics. The experimental results performed with the constructed test-bed applying the Proposed channel probing method and the operation reliability measurement of the overall networked system also support the feasibility of commercially deploying the PLC modem installed home appliances and their services for the Internet accessed home automation in densely populated residential apartment complexes.

  • PDF