• Title/Summary/Keyword: Power system operation

Search Result 5,497, Processing Time 0.041 seconds

정보통신용 다병렬 운전의 모듈식 무정전전원장치 (Module UPS of multi-parallel operation for use in information & telecommunication systems)

  • 구태근;류지수;배상규;박근갑
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.390-393
    • /
    • 2007
  • The reliability as well as the power capability of the UPS system can be increased by replacing a single UPS unit with multiple small UPS units in parallel, resulting in a so-called module UPS. This module UPS system allows that a new module can be added or replaced while maintaining power to loads, which is a hot-swappable operation. In addition, it has desirable features such as ease of output power expandability, convenience of maintenance and repair, and high reliability. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. 5kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the module UPS system has a high power factor, a low distortion of output voltage and input current, hot-swappable operations and good load sharing characteristics.

  • PDF

FRTU 시뮬레이터를 이용한 차세대 배전지능화시스템 네트워크 성능검증 (Network Performance Verification for Next-Generation Power Distribution Management System Using FRTU Simulator)

  • 여상욱;손성용
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.523-529
    • /
    • 2020
  • 배전선로계통의 효율적인 관리와 운영을 위해서 배전지능화시스템은 필수적이다. 배전지능화시스템은 IT를 기반으로 배전망을 통합관리하는 시스템으로 전력산업의 발전과 더불어 진화해 오고 있다. 현재의 배전지능화시스템은 주장치 단위의 독립운전을 기준으로 상대적으로 낮은 네트워크 전송속도로 운영되도록 설계되어있다. 하지만 최근 급속히 보급이 증가하고 있는 태양광이나 에너지 저장장치와 같은 분산자원으로 인하여 미래 배전환경의 운영은 보다 복잡해 지고 있으며 다양한 정보의 실시간 수집이 필요하다. 본 연구에서는 기존의 배전지능화의 한계를 극복하기 위해 차세대 배전지능화 시스템의 요구사항을 도출하였으며, 이를 기반으로 배전계통에 필요한 통신네트워크 체계와 성능요건을 정의하였다. 배전지능화시스템과 같은 대규모 시스템의 현장 도입에는 과도한 시간과 비용이 소요되므로 설계된 시스템의 성능 검증을 위하여 소프트웨어 기반의 단말장치 시뮬레이터를 개발하였다. 시뮬레이터를 활용하여 실제 운영과 유사한 시험환경을 구축하고, 단말장치를 1,000대 까지 증가시켰을 때 제시된 시스템의 네트워크 점유는 최대 10% 이하로 차세대 배전지능화시스템의 기능을 지원하기 위한 네트워크 요구사항을 충족함을 보였다.

수소주거모델의 전력 거래 참여 방안 고찰 (A Study on Power Trading Methods for in a Hydrogen Residential Model )

  • 정기석;정태영
    • 한국수소및신에너지학회논문집
    • /
    • 제34권2호
    • /
    • pp.91-99
    • /
    • 2023
  • Participation in power trading using surplus power is considered a business model active in the domestic energy trade market, but it is limited only if the legal requirements according to the type, capacity, and use of the facilities to be applied for are satisfied. The hydrogen residential demonstration model presented in this paper includes solar power, energy storage system (ESS), fuel cell, and water electrolysis facilities in electrical facilities for private use with low-voltage power receiving system. The concept of operations strategy for this model focuses on securing the energy self-sufficiency ratio of the entire system, securing economic feasibility through the optimal operation module installed in the energy management system (EMS), and securing the stability of the internal power balancing issue during the stand-alone mode. An electric facility configuration method of a hydrogen residential complex demonstrated to achieve this operational goal has a structure in which individual energy sources are electrically connected to the main bus, and ESS is also directly connected to the main bus instead of a renewable connection type to perform charging/discharging operation for energy balancing management in the complex. If surplus power exists after scheduling, participation in power trading through reverse transmission parallel operation can be considered to solve the energy balancing problem and ensure profitability. Consequentially, this paper reviews the legal regulations on participation in electric power trading using surplus power from hydrogen residential models that can produce and consume power, gas, and thermal energy including hybrid distributed power sources, and suggests action plans.

태양광발전시스템의 실증연구를 통한 운용효율 분석 (Using Demonstration PV System for Operation Efficiency Analysis)

  • 박정민;김성결;정병호;조금배;백형래
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.244-246
    • /
    • 2003
  • This paper presents experimental operation with utility invertactive 3kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for Demonstration Complex. The status of photovoltaic generation system components and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for Demonstration Complex.

  • PDF

PSS/E를 이용한 제주계통의 DFIG 풍력발전단지 및 HVDC 동적모델 개발 (Development of Dynamic Models for DFIG Wind Farms and HVDC in Jeju Power System Using PSS/E)

  • 남순열;강상희;남해곤;최준호
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2183-2189
    • /
    • 2011
  • Since main portion of the required electric power in Jeju Island is provided from the mainland through two HVDC lines, Jeju HVDC has a most significant impact on Jeju power system. Average wind speed of Jeju Island is the highest among several candidates in South Korea. So, Jeju Island has been a suitable site for the construction of wind farms where several wind farms are now operating and several others to be sited. Since the large-scale wind generation could have adverse impacts on the stable operation of Jeju power system, wind power is also important for the stability of Jeju power system. Therefore, accurate modeling of Jeju HVDC and wind farms is required for stability analysis of Jeju power system. In this paper, PSS/E-based dynamic modeling of Jeju HVDC and DFIG wind farms is proposed. Model-writing technique of PSS/E is used to develop USRAUX model and USRMDL model for controlling the frequency of HVDC and imposing an operation limit of wind power, respectively. Dynamic characteristics of Jeju HVDC and DFIG wind farms are analyzed through the dynamic simulations. The simulation results show the effectiveness of the developed models for Jeju power system.

배전계통에 연계된 전지전력저장시스템의 유.무효전력 제어 (Active and Reactive Power Control of the Battery Energy Storage System interconnected with Power Distribution System)

  • 김재철;문선호;최준호;김응상
    • 조명전기설비학회논문지
    • /
    • 제13권4호
    • /
    • pp.127-133
    • /
    • 1999
  • 본 논문은 배전계통에 전지전력저장시스템(Battery Energy Storage System: BESS)를 연계하여 운전하는 경우 BESS의 유.무효전력 제어에 대하여 연구하였다. BESS을 배전계통에 연계하는 경우, 이의 유.무효전력 출력을 제어함으로써 배전계통에 일정 전력을 공급, 첨두 부하를 삭감하고 전압을 보상할 수 있다. 본 논문에서는 배전계통과 전지전력저장시스템을 등가 모델링 하였고 전지전력저장시스템의 유.무효 전력제어를 위한 전력 조류 방정식을 제시하였다. 본 논문에서는 BESS의 유.무효전력을 제어하기 위하여 $P-\delta$와 Q-V 제어를 사용하였고 이를 입증하기 위하여 BESS의 유.무효전력 제어를 PSCAD/EMTDC 프로그램을 이용하여 시뮬레이션 하였다.

  • PDF

Optimal Capacity and Allocation of Distributed Generation by Minimum Operation Cost in Distribution Systems

  • Shim Hun;Park Jung-Hoon;Bae In-Su;Kim Jin-O
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권1호
    • /
    • pp.9-15
    • /
    • 2005
  • In the operation of distribution systems, DGs (Distributed Generations) are installed as an alternative to extension and the establishment of substations, transmission and distribution lines according to the increasing power demand. In the operation planning of DGs, determining optimal capacity and allocation achieves economical profitability and improves the reliability of power distribution systems. This paper proposes a determining method for the optimal number, size and allocation of DGs in order to minimize the operation costs of distribution systems. Capacity and allocation of DGs for economical operation planning duration are determined to minimize total cost composed with power buying cost, operation cost of DGs, loss cost and outage cost using the GA (Genetic Algorithm).

발전소 직류 제어회로 과도현상 분석 및 보조계전기 선정 적합성 검토 (A Analysis of DC Control Circuit Transient and a Study of Auxiliary Relay Design Compatability in the Power Plant)

  • 선현규;홍영희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1948_1949
    • /
    • 2009
  • All the power generating station require dc auxiliary power systems to operate those dc components that must be available if a loss of ac power occur. Some examples of such components are auxiliary motors, circuit breakers, relays and solenoids. The dc source may be one common battery for both power and control or two separate batteries; one for power and another for control. Typically, a dc auxiliary power system is designed as an ungrounded system, instead of grounded system, so that a low-resistance ground fault on one of its two polarities will not affect the operation of the system, thus increasing system reliability and continuity of service. A ground detector should provide a high polarity-to-ground resistance so that a single ground fault occurring on the system will not affect the operation of that system. Sensitive relays have been known to energize momentarily while the cable and capacitive charge to ground shifts[1]. A power station had experienced this kind of incident and performed root cause analysis based on PC based simulation program known as PSpice. This simulation showed adapted relays on the system energize momentarily and design criteria on this relay should be corrected.

  • PDF

전기설비의 고조파 분석을 위한 측정 시스템의 개발 (Development of Measurement System for Harmonic Analysis of Electric Equipment)

  • 유재근;이상익;전정채
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.259-261
    • /
    • 2002
  • Recently, according to the spread of semiconductor applied technology like motor speed control contrivance, power conversion installation and so on, harmonic ingredients occurred in switching operation flow into a distribution system and increase voltage distortion of distribution system and bring on obstacles like damage, lowering of capability, false operation and so on of various electrical installation. So, in order to consider a countermeasure to limit occurrence quantity of harmonic source, harmonic interception and others, precision measurement and analysis on voltage, current, power, power factor, the each ingredient of harmonic order, the percentage of total harmonic distortion and so forth are needed. In this paper monitoring system to measure and analyze power quality connected with power harmonics was developed and it's performance is verified by measuring and analyzing three-phase voltage and current of R, S, T in the three-phase and four-wire system using the developed measurement system.

  • PDF

전력시스템 보호를 위한 웹기반 계전기 정정 프로그램 개발 (Development of Web-based Protection Relay Setting Program in Power System)

  • 복정송;정호성;신명철;조인숙;서희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.246-248
    • /
    • 2001
  • For protection of power system, it is a prerequisite to action characteristics of protective relay about a changing environment in power system and correcting the setting value. A substation operator always reside to correct of a relay, however there are problem of efficiency. Recently, power system operation become manless and supervision and control of incident is required anywhere, introduction of new concept as a intellectual manless protective relay is a recent trend. This paper is the web-based protective relay setting program that a manager make an analysis of operation and incident of power system through the web at a remote place corresponding recent manless of system and approach the protection relay and then can correct the error.

  • PDF