• 제목/요약/키워드: Power system operation

검색결과 5,480건 처리시간 0.029초

전력계통(電力系統) 기상정보(氣象情報)시스템의 도플러레이다 위치(位置) 선정(選定) (Doppler Rader Location of Weather Information System for Power System Operation)

  • 김영한;이효상;김재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.206-210
    • /
    • 1989
  • With the economy expands and the increasing living standard of people, the better quality of electricity which is closely related with weather conditions should be supplied to the customers especially using precised facilities. In this paper, the configuration of the weather information system and its application to the power system operation are generally introduced. And also, a method with test result is presented to find the suitable radar coverage area including the condition of electromagnetic wave shut off.

  • PDF

전력수급 종합시스템 운용현황 및 개선방안 (The Plan to Improve Highly Integrated Total Energy System)

  • 박시우;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.326-329
    • /
    • 2001
  • The main purpose of HITES(Highly Integrated Total Energy System) is to build and develop an integrated energy system for power system operational planning and analysis which consists of load forecast, economic generation schedule, stability analysis and relational database system. The HITES can be utilized to supply a stable electric power and operate KEPCO's power system facilities economically. This system was put into operation in 1999. This paper describes the present condition for operation of HITES and proposes the plan to improve this system after installation.

  • PDF

변동비반영 전시장(CBP)에서의 양수발전기 운영방안 (An Operation Method of Pumped Storage Hydroplants in The Cost Based Pool)

  • 김광인;김두중;박만근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.108-111
    • /
    • 2001
  • The electric power industries in Korea are launched into deregulation by introducing the CBP(Cost Based Pool), where generation sector of KEPCO was divided into six generation companies and the other sectors of KEPCO remains vertically integrated system. In deregulated market, participants are concerned with maximization of their profit rather than minimization of system-wide costs. Consequently, there are difficulties in applying the cost minimization for the scheduling of generation resources to CBP, because of the operation of pumped-storage hydroplants. This paper presents an operation method of pumped storage hydroplants which is helpful for the economic operation of power system considering the market in the CBP.

  • PDF

Integrating Operation of Dispersed Generation to Automation Distribution Center for Distribution Network Reconfiguration

  • Park, Joon-Ho;Kim, Jae-Chul;Moon, Seung-Il
    • KIEE International Transactions on Power Engineering
    • /
    • 제2A권3호
    • /
    • pp.102-108
    • /
    • 2002
  • Due to the many attractive aspects of DG in the future power distribution system, distribution automation will be a center hub of integration of the distribution system and resources to satisfy the various needs of customers in a competitive and deregulated environment. In this paper, operation strategies are presented which use network reconfiguration of the automated distribution systems with DG as a real-time operation tool for loss reduction and service restoration from the view of distribution operation. The algorithms and operation strategies of an automated distribution system with DG are introduced to achieve the positive effects of DG in distribution systems. A simple case study shows the effectiveness of the proposed operation strategies.

라오스 남능강 유역 다중 저수지 시스템의 최적 수력발전 운영규정 곡선 개발 (Development of Multi-Reservoir System Operation Rule Curves for Hydropower Maximization in the Nam Ngum River Basin of Lao PDR)

  • 이현재;장웅철;이일주;이진희
    • 대한토목학회논문집
    • /
    • 제42권6호
    • /
    • pp.803-814
    • /
    • 2022
  • 라오스 정부는 증가할 것으로 예상되는 전기 수요량을 충족하기 위해, 남능강 유역 내에 기존 8개소의 발전소 외에도 발전소 댐을 지속적으로 개발하고 있거나 기존 발전소의 발전 설비용량을 증설하고 있다. 이에 따라 라오스 정부는 발전소를 효율적으로 운영하기 위해 기존 저수지 운영규정 곡선(reservoir operation rule curve)을 갱신할 필요성을 제기하였다. 본 연구는 이를 위해 범용적인 동적 계획법(Dynamic Programming:DP) 프로그램인 CSUDP를 활용하여 발전소에서 생산되는 연간 발전량을 극대화하기 위해 현재의 단독 운영체계 외에 연계 운영체계도 검토하였다. 이의 결과로부터 적절한 운영규정 곡선 형태(URC/LRC, MRC)를 추출하였고, 이를 HEC-ResSim 프로그램의 저수지 운영 세트의 운영기초 자료로 입력하여 연간 발전량을 모의하였다. 모의된 연간 발전량과 기존의 운영규정 곡선, 운영실적, 그리고 현장 운영자의 의견 등을 종합하여, 대상 발전소의 연간 발전량을 최대화하는 최적의 저수지 운영규정 곡선(reservoir operation rule curve)을 개발하였다. 이 경우, 저수지를 연계하여 운영하는 체계가 저수지 단독의 운영체계보다 연계에 따른 시너지 효과로 약 2.5 %의 발전량을 더 생산하는 것으로 모의 되었다.

독립형 신재생발전 시스템의 효율적인 운영을 위한 배터리 용량산정에 관한 연구 (A Study on Sizing of Battery for Effective Operation of Stand-alone Renewable Generation System)

  • 신희상;허재선;윤상윤
    • 전기학회논문지P
    • /
    • 제67권1호
    • /
    • pp.15-20
    • /
    • 2018
  • This paper presents the method of ESS energy capacity calculation for stand-alone renewable energy generation system consisting of photovoltaic energy. There is almost no power from photovoltaic system during sunless days. So this source is very weak in terms of the power supply reliability. To improve problem of power supply, battery is mainly used Energy Storage System(ESS). The number of sunless days and Depth of Discharge(DOD) is important factor to determine energy capacity of battery. However, a many study for economical design is required due to the high cost of ESS. In this paper, we propose the new method of ESS energy capacity calculation by applying different DOD for operation with and without sun. We determine the Battery capacity using higher DOD of operation during sunless day than the DOD of the normal operation. And we carried out an economic analysis of the calculation results.

풍력발전단지의 효율적 운영을 위한 퍼지로직 기반 주파수 제어기 설계 (A Design for a Fuzzy Logic based Frequency Controller for Efficient wind Farm Operation)

  • 김세윤;김성호
    • 제어로봇시스템학회논문지
    • /
    • 제20권2호
    • /
    • pp.186-192
    • /
    • 2014
  • Recently wind energy penetration into power systems has increased. Wind power, as a renewable energy source, plays a different role in the power system compared to conventional power generation units. As long as only single and small wind power units are installed in the power system, wind power does not influence power system operation and can easily be integrated. However, when wind power penetration reaches a significantly high level and conventional power production units are substituted, the impact of wind power on the power system becomes noticeable and must be handled. The connection of large wind turbines and wind farms to the grid has a large impact on grid stability. The electrical power system becomes more vulnerable to and dependent on wind energy production, and therefore there is an increased concern about the large wind turbines impact on grid stability. In this work, a new type of fuzzy logic controller for the frequency control of wind farms is proposed and its performance is verified using SimWindFarm toolbox which was developed as part of the Aeolus FP7 project.

배전계통에서 분산전원 운전가능 범위에 대한 연구 (A Study on Permissible Operation Limit of Distributed Generation System in Distribution System)

  • 정원재;김태응;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.19-21
    • /
    • 2001
  • Nowadays, small scale DGS(Distributed Generation System), as a wind power generation or photovoltaic generation, becomes to be introduced into the power distribution system. But in that case it is difficult to properly maintain the terminal voltage of low voltage customers by using only LDC(Line Drop Compensator). So, it is necessary to determine the permissible operation limit of the introduced DGS for proper voltage in distribution system. In this paper clarifies the relationship between LDC voltage regulation principle and real, reactive power of DGS, and examines the permissible operation limit of the introduced DGS in distribution system which the voltage is controlled by LDC.

  • PDF

A Novel PCCM Voltage-Fed Single-Stage Power Factor Correction Full-Bridge Battery Charger

  • Zhang, Taizhi;Lu, Zhipeng;Qian, Qinsong;Sun, Weifeng;Lu, Shengli
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.872-882
    • /
    • 2016
  • A novel pseudo-continuous conduction mode (PCCM) voltage-fed single-stage power factor correction (PFC) full-bridge battery charger is proposed in this paper. By connecting a freewheeling transistor in parallel with an input inductor, the PFC cell can operate in the PCCM with a constant duty ratio. Thus, the dc/dc stage can be designed using this constant duty ratio and the restriction on the duty ratio of the PFC cell is eliminated. As a result, the input current distortion is less and the dc bus voltage becomes controllable over the wide output power range of the battery charger. Moreover, the operation principle of the dc/dc stage is designed to be similar to that of a conventional phase-shifted full-bridge converter. Therefore, it is easy to implement. In this paper, the operation of the new converter is explained, and the design considerations of the controller and key parameters are presented. Simulation and experimental results obtained from a 1 kW prototype are given to confirm the operation of the proposed converter.

Methodology for Determining of Generator Operation Point for Ensuring Voltage Stability Against Generator Faults in Jeju-Haenam HVDC System

  • Kang, Sang-Gyun;Seo, Sang-Soo;Lee, Byong-Jun;Joo, Joon-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.54-60
    • /
    • 2010
  • This paper presents a new algorithm for determining generator operation point for maintaining stability considering generator faults in Jeju-Haenam HVDC system. As the HVDC system consumes reactive power for the transmission of active power substantially, compensation of reactive power is essential. And the HVDC system is operated on frequency control mode. That is to say, the HVDC system almost manages system frequency. Therefore, we recognized that the Jeju system could be unstable if the reactive power consumed by the HVDC is insufficient when out-of-step occurs with large generators. When the solution of power flow analysis does not converge due to the unstable system phenomenon, we have difficulty in establishing countermeasures as the post-fault information is not available. In this paper, for the purpose of overcoming this difficulty in establishing countermeasures, we introduce the CPF(Continuation Power Flow) algorithm. This paper suggests an algorithm for calculating the output limitation of the generator to maintain the stability in case of generator fault in the Jeju system.