• Title/Summary/Keyword: Power size

Search Result 5,383, Processing Time 0.033 seconds

Performance analysis ofthe improved reverse link closed loop powercontrol with the variable step size for the mobile transmit power (이동국 가변증감량 조정방법에 의한 역방향 폐쇄회로 전력제어 성능개선 연구)

  • 원석호;정인명;임덕채;김환우
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.6
    • /
    • pp.1567-1575
    • /
    • 1996
  • This paper presents a new power control method for compensating the short term fading of the reverse link channel in the CDMA mobile telephone system. The fixed step closed loop power control which is now adopted in IS-95, is very simple in structure. However, the step size in the closed loop power control is too big for the channel with a small variation or too big for the channel with a small variation or too small for the channel with a large variation. The method presented in this paper has a simple structure and shows a new model employing the combination of the fixed step size method and variable step size method which results in compensatingthe disadvantages mentioned above. This paper also evaluates the performance inthe fundamental channel model.

  • PDF

Power Analysis in Experimental Designs with t test Analysis (t 검정 실험 설계 시 표본 크기 결정에 대한 논의)

  • Kang, Jeong-Hee;Bang, Kyung-Sook;Ko, Sung-Hee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.15 no.1
    • /
    • pp.120-127
    • /
    • 2009
  • Purpose: In the literature power analysis in experimental studies is often executed and reported falsely. This descriptive study was done to promote the correct application of the Cohen(1988)'s power analysis method. Method: Articles of experimental studies from a nursing journal were selected and reviewed to examine the uses of and the reports on the power analysis process. Also, the appropriate power analysis process was discussed with an example of the most common experimental design, an independent two-group design with t test analysis plan. Result: Around half the experimental studies examined reported that they carried out power analysis. Cohen's method was the most frequently utilized but with accuracy in question. Conclusion: Power analysis to estimate sample size is the interplay between alpha, power, and effect size, and other factors in the case of t test analysis. Researchers should have a clear understanding of how to apply the Cohen's power analysis method so they do not produce poorly estimated sample sizes.

The Dispersion Stability of $\alpha-Fe_2O_3$ Particulate Soil in the Anionic/Nonionic Mixed Surfactant Solution (음/비이온계 혼합계면활성제 용액에서 $\alpha-Fe_2O_3$ 입자의 분산안정성)

  • 정선영;강인숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.6
    • /
    • pp.854-861
    • /
    • 2004
  • To estimate dispersion stability of particles in anionic and nonionic surfactant mixed solution, suspending power was examined as functions of duration time of suspension, ionic and nonionic surfactant mixed ratio, surfactant concentration, kinds of electrolyte, ionic strength and mole numbers of oxyethylene additions to nonionic surfactant using $\alpha$-Fe$_2$O$_3$ particle as the model of particulate soil. The suspending power of anionic and nonionic surfactant mixed solution was relatively higher than that of anionic and nonionic surfactant single solution regardless of solution concentration. The suspending power was gradually decreased with increasing duration time of suspension. In the absence of electrolyte, the effect of surfactant concentration on suspending power was small but in solution with electrolyte, suspending power was lowest at 1 % surfactant concentration. With 1${\times}$10$^{-3}$ ionic strength and polyanionic electrolyte in solution, the suspending power was high but effects of oxyethylene mole number to nonionic surfactant on suspending power was small. Generally the suspending power was gradually increased with decreasing the particle size. Hence the suspending power was inversely related to the particle size.

Analysis of Determining Factors for Power Size of a Tractor (트랙터의 출력수준 결정에 영향을 미치는 요인 분석)

  • Kim, Byoung-Gap;Lee, Won-Ok;Shin, Seung-Yeop;Kim, Hyeong-Kwon;Kang, Chang-Ho;Rhee, Joong-Yong
    • Journal of Biosystems Engineering
    • /
    • v.34 no.1
    • /
    • pp.8-14
    • /
    • 2009
  • When a farmer buys a tractor, the power size of a tractor is determined by various factors such as farm size, farmer's age, farming type, topographical area of farm. Relationships between tractor selection and these factors were found. Three regression models were developed to analyze the relationship. Those models were an OLS-1 model (based on 567 samples having tractors), an OLS-2 model, and a Tobit model (both based on the 1,941 samples). Regression analysis results showed that farm size and farmer's age affected selection of power size for all models at an 1% significance level. It was also shown that some farming types also had significant relationships with the tractor power size. Upland cultivating farmers and livestock farmers had larger tractors than rice cultivating farmers, while orchard farmers had smaller tractors. As for the topographical area, only middle area had significant difference with plain area. Farmers who had a rice-transplanter or a combine had larger tractors than those who didn't.

Small-size Specimen's Effectiveness That is Used to Mortar Layer of Slab (Heavy-weight Floor Impact Sound) (슬래브 상부 몰탈층에 사용된 작은시편의 유효성 검토(중량충격음을 중심으로))

  • Chung, Jin-Yun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.184-191
    • /
    • 2009
  • This study examined small-size specimen's effectiveness that is used to evaluate floor impact sound performance. Floor impact sound level of small-size specimen is higher than full-size. This is due to excessive impact power of Bang machine. Impact hammer that has small impact power relatively can solve this problem. But, according to the size of specimen, mode shape and frequency that influence to structural borne sound is changed. Slab mode of full-size specimen was changed to frequency design of resilient materials. But in case of small-size specimen, there is no change of vibration mode by resilient materials change, Vibration mode of small-size specimen is the same. Therefore, it is not proper that use small-size specimen in floor impact sound estimation.

The Converter of High Efficiency 48V 400A for Electronic Exchange (전자교환기용 고효율 48V 400A급 전력변환장치의 시작)

  • 박성우;서기영;전중함;김부국;이현우
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.60-63
    • /
    • 1998
  • The widely used power supply (Switched Mode Power Supply : SMPS) as a source in order to stabilize direct current for electronics or communication systems has merits, when it is compared to the existing source for stability, such as high efficiency, small size, light weight by means of switching process of the semiconductor device which controls the flow of power. However, due to existence of inductors and capacitors used for charging energy, the source part in electronic or communication systems hasn't reached the speed, that is supposed to get, for achieving smaller size and lighter weight. In order to get smallness in size, it is necessary to increase switching frequency. And that makes devices for measuring energy smaller. Nevertheless, the rise switching frequency brings increases in switching loss, inductor loss, and power loss. Also, the occurrence of surge and noise caused by high frequency switching is getting higher. The resonant converter has been considered as one of methods that give solutions for the problems of SMPS and that method have been paid attention as a source technology in electronics and communication.

  • PDF

Sputtering of Multifunctional AlN Passivation Layer for Thermal Inkjet Printhead

  • Park, Min-Ho;Kim, Sang-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.50-50
    • /
    • 2011
  • The aluminum nitride films were prepared by RF magnetron sputtering using an AlN ceramic target. The crystallinity, grain size, Al-N bonding and thermal conductivity were investigated in dependence on the plasma power densities (4.93, 7.40, 9.87 W/$cm^2$) during sputtering. High thermal conductivity is important properties of A1N passivation layer for functioning properly in thermal inkjet printhead. The crytallinity, grain size, Al-N bonding formation and chemical composition were observed using X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), fourier transform infrared (FTIR) and X-ray photoelectron spectroscopy (XPS), respectively. The AlN thin film was changed from amorphous to crystalline as the power density was increased, and the largest grain size appeared at medium power density. The near stoichiometry Al-N bonding ratio was acquired at medium power density. So, we know that the AlN thin film had better thermal conductivity with crystalline phase and near stoichometry Al-N bonding ratio at 7.40 W/$cm^2$ power density.

  • PDF

Single Stage PFC Flyback Converter Using Top Switch (Top 스위치를 이용한 단일 전력단 역률개선 플라이백 컨버터)

  • Lim Chang Seob;Kwon Soon Kurl;Lee Hyun Woo;Kim Eun Soo
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.669-672
    • /
    • 2001
  • Generally, previous converter is divided into two categories to get high power factor and good output regulation. These two categories can be combined a category with a main switch. These converter is called Single Stage PFC Converter. This approach has good electrical characteristics of high power factor and fast output voltage regulation. The cost and size are important factor to design the converter in low power system. Even single stage can reduce the size and cost, but this approach needs to have additional circuit like control, PWM circuit. To improve these demerits, Top switch is one of good choice In reduce and size in low power single stage converter. Because it has the ability of current limit, thermal protection, oscillator, control circuit as well as a main switch ability.

  • PDF

Power Estimation and Follow-Up Period Evaluation in Korea Radiation Effect and Epidemiology Cohort Study (원전 코호트 연구의 적정 대상규모와 검정력 추정)

  • Cho, In-Seong;Song, Min-Kyo;Choi, Yun-Hee;Li, Zhong-Min;Ahn, Yoon-Ok
    • Journal of Preventive Medicine and Public Health
    • /
    • v.43 no.6
    • /
    • pp.543-548
    • /
    • 2010
  • Objectives: The objective of this study was to calculate sample size and power in an ongoing cohort, Korea radiation effect and epidemiology cohort (KREEC). Method: Sample size calculation was performed using PASS 2002 based on Cox regression and Poisson regression models. Person-year was calculated by using data from '1993-1997 Total cancer incidence by sex and age, Seoul' and Korean statistical informative service. Results: With the assumption of relative risk=1.3, exposure:non-exposure=1:2 and power=0.8, sample size calculation was 405 events based on a Cox regression model. When the relative risk was assumed to be 1.5 then number of events was 170. Based on a Poisson regression model, relative risk=1.3, exposure:non-exposure=1:2 and power=0.8 rendered 385 events. Relative risk of 1.5 resulted in a total of 157 events. We calculated person-years (PY) with event numbers and cancer incidence rate in the nonexposure group. Based on a Cox regression model, with relative risk=1.3, exposure:non-exposure=1:2 and power=0.8, 136 245PY was needed to secure the power. In a Poisson regression model, with relative risk=1.3, exposure:non-exposure=1:2 and power=0.8, person-year needed was 129517PY. A total of 1939 cases were identified in KREEC until December 2007. Conclusions: A retrospective power calculation in an ongoing study might be biased by the data. Prospective power calculation should be carried out based on various assumptions prior to the study.

Palm-Size-Integrated Microwave Power Module at 1.35-GHz for an Atmospheric Pressure Plasma for biomedical applications

  • Myung, C.W.;Kwon, H.C.;Kim, H.Y.;Won, I.H.;Kang, S.K.;Lee, J.K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.498-498
    • /
    • 2013
  • Atmospheric Pressure Plasmas have pioneered a new field of plasma for biomedical application bridging plasma physics and biology. Biological and medical applications of plasmas have attracted considerable attention due to promising applications in medicine such as electro-surgery, dentistry, skin care and sterilization of heat-sensitive medical instruments [1]. Traditional approaches using electronic devices have limits in heating, high voltage shock, and high current shock for patients. It is a great demand for plasma medical industrial acceptance that the plasma generation device should be compact, inexpensive, and safe for patients. Microwave-excited micro-plasma has the highest feasibility compared with other types of plasma sources since it has the advantages of low power, low voltage, safety from high-voltage shock, electromagnetic compatibility, and long lifetime due to the low energy of striking ions [2]. Recent experiment [2] shows three-log reduction within 180-s treatment of S. mutans with a low-power palm-size microwave power module for biomedical application. Experiments using microwave plasma are discussed. This low-power palm-size microwave power module board includes a power amplifier (PA) chip, a phase locked loop (PLL) chip, and an impedance matching network. As it has been a success, more compact-size module is needed for the portability of microwave devices and for the various medical applications of microwave plasma source. For the plasma generator, a 1.35-GHz coaxial transmission line resonator (CTLR) [3] is used. The way of reducing the size and enhancing the performances of the module is examined.

  • PDF