• Title/Summary/Keyword: Power series method

검색결과 843건 처리시간 0.026초

Prediction of the Radiated Emission(RE)s due to the PCB Power-Bus' Resonance Modes and Mitigation of the RE Levels

  • Kahng, Sung-Tek
    • Journal of electromagnetic engineering and science
    • /
    • 제7권1호
    • /
    • pp.7-11
    • /
    • 2007
  • PCB Power-Bus (comprising power/ground planes) impedance and fields are evaluated by an efficient series expansion method that is suggested in this paper. It is used to investigate the structure's radiated emission(RE) levels and find acceptable ways of loading the power/ground planes such as decoupling capcitor(DeCap)s, balanced feeding and slits, in order to reduce the interferences. Also, the calculations and measurements of a proposed geometry are verified by vector fitting as a analysis model to check the behavior of the slit.

이중 결합 Full-Bridge 방식 직렬 공진형 인버터 (A Double Coupling Full-Bridge Configuration Series Resonant Inverter)

  • 배영호
    • 전력전자학회논문지
    • /
    • 제9권4호
    • /
    • pp.326-333
    • /
    • 2004
  • 본 논문에서는 Power-MOSFET를 통해 L및 C로 링크된 2조의 공진형 Full-bridge 인버터 회로를 다중 결합하여 대용량 전력변환장치의 소자에 인가되는 전압이나 부하전류를 분산 제어하는 기법을 제안하고 있다. 이 방식은 두 조의 인버터가 시분할로 구동되기 때문에 각 인버터의 독립된 출력이 부하단에서 합성되어 전력이 공급된다. 출력제어 기법은 시분할 합성법을 사용하고 이에 따른 인버터의 회로동작 모드를 분석하고 해석하였으며, 시뮬레이션을 통한 이론적 해석결과를 검정하고 이를 실험을 통해 비교 고찰하였다.

Modeling and Control of VSI type FACTS controllers for Power System Dynamic Stability using the current injection method

  • Park, Jung-Soo;Jang, Gil-Soo;Son, Kwang-M.
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권4호
    • /
    • pp.495-505
    • /
    • 2008
  • This paper describes modeling Voltage Sourced Inverter (VSI) type Flexible AC Transmission System (FACTS) controllers and control methods for power system dynamic stability studies. The considered FACTS controllers are the Static Compensator (STATCOM), the Static Synchronous Series Compensator (SSSC), and the Unified Power Flow Controller (UPFC). In this paper, these FACTS controllers are derived in the current injection model, and it is applied to the linear and nonlinear analysis algorithm for power system dynamics studies. The parameters of the FACTS controllers are set to damp the inter-area oscillations, and the supplementary damping controllers and its control schemes are proposed to increase damping abilities of the FACTS controllers. For these works, the linear analysis for each FACTS controller with or without damping controller is executed, and the dynamic characteristics of each FACTS controller are analyzed. The results are verified by the nonlinear analysis using the time-domain simulation.

전력용 커패시터의 전기적 스트레스 해석 (Analysis for Electrical Stress of Power Capacitor)

  • 김종겸;박영진;이은웅;이동주
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.370-376
    • /
    • 2008
  • Power capacitors is widely used for power factor correction and component of passive filter in the user power systems. Recently, application of non-linear load is gradually increased. Non-linear load produces harmonic components of current. There are series resonance and parallel resonance when capacitors are applied in the user electrical application. If this harmonic component matches resonance, voltage and current is magnified and has severely an influences on capacitor. This paper purposes a new method for the magnitude of voltage and current by the frequency scan analysis without equivalent circuit for the actual circuit at the resonance condition.

태양광 시스템의 최대 전력지점 추적(MPPT) 정확도 향상을 위한 모델링 (Improved Model for Maximum Power Point Tracking (MPPT) of Solar System)

  • 이영현;이종환
    • 반도체디스플레이기술학회지
    • /
    • 제21권1호
    • /
    • pp.114-118
    • /
    • 2022
  • The photovoltaic system is affected by various conditions such as temperature and irradiance. Because non-uniform irradiation and partial shading conditions affect the entire string of cells connected in series, a bypass diode is used to bypass the current flow normally. In order to find the maximum power point in partial shade conditions, it is necessary to estimate various methods of maximum power point tracking. In this paper, the hybrid method of MPPT using Lambert W function and perturbation & observation algorithm is proposed under partial shading conditions. The simulation results are obtained using MATLAB/Simulink and shows the improvement of the accuracy of MPPT.

Fatigue performance and life prediction methods research on steel tube-welded hollow spherical joint

  • Guo, Qi;Xing, Ying;Lei, Honggang;Jiao, Jingfeng;Chen, Qingwei
    • Steel and Composite Structures
    • /
    • 제36권1호
    • /
    • pp.75-86
    • /
    • 2020
  • The grid structures with welded hollow spherical joint (WHSJ) have gained increasing popularity for use in industrial buildings with suspended cranes, and usually welded with steel tube (ST). The fatigue performance of steel tube-welded hollow spherical joint (ST-WHSJ) is however not yet well characterized, and there is little research on fatigue life prediction methods of ST-WHSJ. In this study, based on previous fatigue tests, three series of specimen fatigue data with different design parameters and stress ratios were compared, and two fatigue failure modes were revealed: failure at the weld toe of the ST and the WHSJ respectively. Then, S-N curves of nominal stress were uniformed. Furthermore, a finite element model (FEM) was validated by static test, and was introduced to assess fatigue behavior with the hot spot stress method (HSSM) and the effective notch stress method (ENSM). Both methods could provide conservative predictions, and these two methods had similar results. However, ENSM, especially when using von Mises stress, had a better fit for the series with a non- positive stress ratio. After including the welding residual stress and mean stress, analyses with the local stress method (LSM) and the critical distance method (CDM, including point method and line method) were carried out. It could be seen that the point method of CDM led to more accurate predictions than LSM, and was recommended for series with positive stress ratios.

ECU 응답특성 분석을 통한 T-50 계열 항공기 보조동력장치 자동 꺼짐 개선에 관한 연구 (A study on the improvement of Auxiliary Power Unit auto-shutdown of T-50 series aircraft based on analysis of ECU response characteristics)

  • 박성제;유인제;최수진;이동기
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.640-646
    • /
    • 2017
  • T-50 계열 항공기는 비행 전 지상에서 비상동력계통 작동 점검을 위해 보조동력장치 GEN TEST를 수행하게 된다. 만일 GEN TEST 수행 중 비상동력계통에 전원이 정상적으로 공급되지 않을 경우 ECU의 응답 신호를 통해 보조동력장치가 자동으로 꺼지는 현상이 발생하게 되며, 지상에서 비상동력계통 작동 점검이 정상적으로 이루어지지 않을 경우 더 이상 비행을 할 수 없기 때문에 해당 결함은 항공기 가동률 저하에 큰 원인이 된다. ECU에서 식별된 결함코드는 인버터 결함으로 판별되었으나 인버터 교체 이후에도 동일한 결함이 지속적으로 반복되었다. 본 논문은 인버터가 특정 시간 안에 전압을 생성시키지 못 할 경우 ECU에서는 결함으로 식별되는 것이 확인되었으며, 보조/비상동력계통의, BSG, ESC, 및 ECU의 응답특성을 분석하여 개선된 방법을 제시한다. 또한, 개선된 방법에 대한 검증을 통해 비상동력계통 출력 요구시간 범위 안에 인버터 출력이 정상적으로 생성되는 것을 확인하였으며, 이를 통해 비행전 지상에서 GEN TEST 수행 시 보조동력장치 자동 꺼짐 현상을 효과적으로 예방 할 수 있음을 확인 하였다.

ZCS형 역률 개선 회로(QBSRR)의 데드빗(deadbeat)제어기 설계 (Deadbeat Controller Design of a ZCS-type Power Factor Correction Circuit(QBSRR))

  • 최현칠
    • 전력전자학회논문지
    • /
    • 제3권2호
    • /
    • pp.107-117
    • /
    • 1998
  • 근래에 들어, 입력 교류전원에서 양질의 전력을 공급하기 위하여 역률 개선 회로에 대한 연구가 활발히 진행되고 있다. 그 중 QBSRR이라는 ZCS(Zero Current Switching) 공진형 역률 개선 회로가 최근에 소개되었는데, 본 논문에서는, QBSRR회로의 전력단에 대하여 간단하고 정확한 모델링을 이용하여 안정된 출력 전압과 빠른 동적특성을 얻기 위한 데드빗(Deadbeat) 제어기를 체계적으로 설계하였다. 또한, 전류 센서를 사용하지 않고 부하 저항값을 파악하기 위하여 부하 예측 기법(Load Estimation Method)을 유도하였다. 본 논문에서는 제안한 제어기를 이용하면, 역률개선 회로의 출력측에 나타나는 120Hz의 리플에도 불구하고 안정된 출력전압과 빠른 동적 특성을 얻을 수 있게 된다. 아울러, 과도 응답 상태에서도 입력측의 높은 역률이 유지되는 장점을 가지고 있다. 시뮬레이션과 실험을 통하여 본 논문에서는 제안한 제어기의 우수한 특성을 입증하였다.

레이저 표면 경화 공정의 계측 및 제어에 관한 연구 (A study on monitoring and control in laser transformation hardening process)

  • 우현구;조형석;한유희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.883-888
    • /
    • 1993
  • This paper proposes a monitoring method using an infrared temperature sensor in laser surface hardening process. To investigate the validity of the method a series of experiments are performed for various conditions. The experimental results show that the surface temperature depends upon the laser power, travelling speed and surface conditions of a specimen. Especially, the laser surface hardening process is greatly influenced by the surface conditions of the specimen, such as coating thickness and materials.

  • PDF

단상 다기능 UPS 입.출력 필터 설계 (Design of Input.Output Filter of Single Multifunctional UPS)

  • 김제홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.307-310
    • /
    • 2002
  • A design for the input filter and the output filter of a single-phase UPS system is proposed. And also, this paper describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.

  • PDF