• 제목/요약/키워드: Power series method

검색결과 843건 처리시간 0.025초

계통 주파수 추정을 위한 디지털 알고리즘 간의 비교 (A comparison between digital algorithms for estimation of power system frequency)

  • 이병현;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.276-277
    • /
    • 2006
  • Estimation of power system frequency is an important task because frequency deviation is a good indicator of the system abnormal operating conditions. The algorithms, curve fitting, technique using Taylor series, deviation of phasor angle of fundamental waveform using DFT (Discrete Fourier Transform) and Prony method, are tested under operation of the frequency relaying by using EMTP MODELS. The performance of methods is compared with the simulation results.

  • PDF

Hybrid형 초전도 한류기의 동시퀜치 유도방안 (A method for simultaneous quench of hybrid type superconducting fault current limiter)

  • 최효상;현옥배;김혜림;박권배;황시돌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.916-917
    • /
    • 2001
  • We investigated the properties of a hybrid type superconducting fault current limiter (SFCL), which consists of a transformer with multiple secondary windings and resistive $YBa_2Cu_3O_7$ (YBCO) thin film stripes. The secondary windings of the transformer were coupled with each other, and a superconducting current limiting unit of YBCO stripes was connected to each of them as a switch. Simple connection in series of SFCL units tends to produce imbalance in power among the units due to slight differences in quench current. In current design, magnetic coupling between the SFCL units provides a solution to power dissipation imbalance, inducing simultaneous quench by current redistribution in the YBCO films.

  • PDF

FACTS 기기를 이용한 전력시스템의 안전도 향상 (The Enhancement of Power System Security Using flexible AC Transmission Systems (FACTS))

  • 송성환;임정욱;문승일
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.165-172
    • /
    • 2003
  • This paper presents an operation scheme to enhance the power system security by applying FACTS on Power systems. Three main generic types of FACTS devices are suggested an illustrated. Flow congestions over lines have been solved by controlling active power of series-compensated FACTS devices and low voltages at buses have been solved by controlling reactive power of shunt-compensated FACTS devices. Especially, Especially, UPFC has been applied in both line congestion and low voltages. Two kinds of indices which indicate the power system security level related to line flow and bus voltage are utilized in this paper. They have been minimized to enhance the power system security level through the iterative method and the sensitivity vector of security index is derived to determine the direction to minimum. The proposed algorithm has been tested on the IEEE 57-bus system with FACTS devices in a normal condition and a line-faulted contingency.

물리적인 전력소자 모델을 이용한 직$\cdot$병렬운전 특성 해석 (Analysis of Series and Parallel Operation Characteristics using Physical Models of Power Devices)

  • 윤재학;박건태
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.213-217
    • /
    • 2002
  • Power devices for high power drivers that need high switching speed (IGCT, HVIGBT) have been continuously developed. However, serial and parallel connections using several much cheaper, lower power capacity of devices than an expensive high power device are very useful methods in the aspect of cost down and high power application. Even the current and voltage unbalance problem is occurred at each devices. This unbalance characteristics are mainly caused by the differences of physical characteristics of each devices and the line inductance (stray inductance) of bus bars that consist of current path. This paper deals simulation analysis of serial connection of IGCTs and parallel connection of IGCTs using physical model of devices. And also, introduces the method to reduce the voltage and current unbalance problem.

  • PDF

An improved interval analysis method for uncertain structures

  • Wu, Jie;Zhao, You Qun;Chen, Su Huan
    • Structural Engineering and Mechanics
    • /
    • 제20권6호
    • /
    • pp.713-726
    • /
    • 2005
  • Based on the improved first order Taylor interval expansion, a new interval analysis method for the static or dynamic response of the structures with interval parameters is presented. In the improved first order Taylor interval expansion, the first order derivative terms of the function are also considered to be intervals. Combining the improved first order Taylor series expansion and the interval extension of function, the new interval analysis method is derived. The present method is implemented for a continuous beam and a frame structure. The numerical results show that the method is more accurate than the one based on the conventional first order Taylor expansion.

침출수 처리 응용 펄스전원 시스템 (Pulsed Power System for Leachate Treatment Application)

  • 장성록;안석호;류홍제;임근희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.246-247
    • /
    • 2010
  • This paper deals with the water treatment of the leachate from sewage filled ground by a pulsed power technology. Leachate from sewage filled ground should be treated below regulation level of COD in order to prevent environmental pollution and usually treated by a chemical method. Among the pollutants mixed in the leachate, chemical compounds of benzene series are known to be difficult to break down, and need to use high cost treat methods. The treatment of the benzene compounds by high power pulsed power supply was studied. For the high-rate, cost-effective treatment of leachate, pulsed power supply should have high repetition rates and require switching devices of long lifetime. In order to meet the demands of the above condition, pulsed power generator based on semiconductor switches using IGBTs as primary switches were developed. The experimental results verified that benzene compounds can be treated effectively by high voltage electric pulses, and this fact indicates that the treatment method by pulsed power source is a promising substitute.

  • PDF

An Electric-Field Coupled Power Transfer System with a Double-sided LC Network

  • Xie, Shi-Yun;Su, Yu-Gang;Zhou, Wei;Zhao, Yu-Ming;Dai, Xin
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.289-299
    • /
    • 2018
  • Electric-field coupled power transfer (ECPT) systems employ a high frequency electric field as an energy medium to transfer power wirelessly. Existing ECPT systems have made great progress in terms of increasing the transfer distance. However, the topologies of these systems are complex, and the transfer characteristics are very sensitive to variations in the circuit parameters. This paper proposes an ECPT system with a double-sided LC network, which employs a parallel LC network on the primary side and a series LC network on the secondary side. With the same transfer distance and output power, the proposed system is simpler and less sensitive than existing systems. The expression of the optimal driving voltage for the coupling structure and the characteristics of the LC networks are also analyzed, including the transfer efficiency, parameter sensitivity and total harmonic distortion. Then, a design method for the system parameters is provided according to these characteristics. Simulations and experiments have been carried out to verify the system properties and the design method.

모의실험을 이용한 경향성 분석기법의 검정력 평가 (Power Test of Trend Analysis using Simulation Experiment)

  • 류용준;신홍준;김수영;허준행
    • 한국수자원학회논문집
    • /
    • 제46권3호
    • /
    • pp.219-227
    • /
    • 2013
  • 수문시계열 자료에 변동성, 도약성, 경향성, 주기성 등이 있으면 이러한 자료는 일반적으로 비정상성을 가지며, 특히 경향성 판단을 통한 다양한 방법들이 제시되어 왔다. 그러나 다양한 방법 간의 검정능력에 대한 평가는 많이 이루어지지 않았으며, 그로인해 동일 자료에 대한 다른 방법의 적용으로 반대의 결과가 나오는 경우도 발생하게 된다. 따라서 본 연구에서는 통계적 특성에 따른 경향성 분석의 변화를 파악하고, 경향성 분석방법 간의 검정능력을 파악해 보았다. 이를 위해 경향성 분석기법인 Mann-Kendall 검정, Hotelling-Pabst 검정, t 검정, Sen 검정을 적용하였으며 기울기, 표본크기, 표준편차에 따라 다양한 모의실험을 수행하였다. 그 결과 t 검정이 다른 검정에 비해 상대적으로 높은 검정력을 보였고, Mann-Kendall 검정, Hotelling-Pabst 검정, Sen 검정은 비슷한 결과를 보였다.

TCSC가 적용된 실계통 시스템에서의 TRV와 MOV의 영향에 대한 분석 (Analysis on the Effects of TRV and MOV in Real System with TCSC)

  • 이석주
    • 한국산업정보학회논문지
    • /
    • 제24권2호
    • /
    • pp.41-46
    • /
    • 2019
  • 전력 시스템에서 직렬 보상기의 적용은 회로 차단기 과도 재기 전압 (Transient Recovery Voltage : TRV) 문제와 같은 다른 장치에 영향을 미친다. 본 논문에서는 TCSC (Thyristor-Controlled Series Capacitor)가 있는 경우와 없는 경우의 선로 차단기에 대한 TRV 효과를 시뮬레이션을 통해 분석하고, TCSC 설치로 인한 TRV 증가를 극복하는 효과적인 방법을 제안한다. 또한 금속 산화물 바리스터 (Metal Oxide Varistor : MOV)에 대한 제안된 보호의 영향에 대해서도 설명한다. 시뮬레이션 모델은 국내의 345 kV 송전선로를 사용하였다. 전력 시스템은 PSCAD (Power Systems Computer Aided Design) / EMTDC (Electro Magnetic Transient Direct Current)를 사용하여 모델링하였다. TRV는 송전선로 및 차단기 단자에서 단락 고장을 구현하여 분석하였고, MOV의 에너지는 보호 동작 알고리즘을 적용하여 해석하였다. 제안된 보호 방안을 적용하는 경우 TRV는 표준을 만족시키지만, 지연 시간이 증가함에 따라 MOV 에너지 용량의 증가하여야 한다. 이 결과를 적용하여 실제 전력 시스템에서 예상되는 전송 선로 고장 상태로 인한 TRV 문제를 해결할 수 있다.

엑티브 셀 밸런싱을 위한 새로운 전력 피드백 방식의 플라이백 토폴로지에 관한 연구 (Study on the Fly-back Topology of New Power Feed-back Method for Active Cell Balancing )

  • 강성용;송명진;박성미;박성준;고재하
    • 한국산업융합학회 논문집
    • /
    • 제26권6_2호
    • /
    • pp.1083-1095
    • /
    • 2023
  • Recently, the demand for low-voltage, high-capacity ESS is rapidly increasing due to the revitalization of the e-mobility industry, which is mainly powered by electricity. In addition, the demand for portable power banks is rapidly increasing due to the revitalization of leisure industries such as camping and fishing. The ESS with this structure consists of a small number of series cells and many parallel cells, resulting in a system with a large rated current. Therefore, the number of power devices for cell balancing configured in series is small, but a balancing device with a large current capacity is required. Construction of a constant temperature device in such a low-voltage, high-current ESS is difficult due to economic issues. The demand for an active balancing system that can solve the passive balancing heating problem is rapidly increasing. In this paper, propose a power feedback fly-back topology that can solve the balancing heating problem. The characteristic of the proposed topology is that a series-connected voltage sharing voltage is used as the input of the flyback converter, and the converter output is connected to one transformer. In this structure, the converter output for cell voltage balancing shares magnetic flux through one high-frequency transformer, so the cell voltage connected to the converter automatically converges to the same voltage.