• Title/Summary/Keyword: Power requirement

Search Result 1,003, Processing Time 0.026 seconds

Theoretical analysis of power requirement of a four-row tractor-mounted radish collector

  • Khine Myat Swe;Mohammod Ali;Milon Chowdhury;Md Nasim Reza;Md Ashrafuzzaman Gulandaz;Sang-Hee Lee;Sun-Ok Chung;Soon Jung Hong
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.4
    • /
    • pp.677-696
    • /
    • 2022
  • Development of radish collectors may enhance radish production and promote upland crop mechanization in the Republic of Korea. Theoretical analysis of power is crucial to ensure the optimum design of agricultural machinery. The aim of the present study is to analyze theoretically the power requirement of a tractor-mounted radish collector under development and to propose design guidelines. The important components of the radish collector were belt-type conveyors, three hydraulic motors, and a direct current (DC) winch motor to operate the total radish collecting process. Theoretical equations were used to calculate the hydraulic motor's power, winch motor power, and draft power at loaded and unloaded conditions. A variety of tractors (44 - 74 kW) and different soil characteristics (hard, firm, tilted, and sandy) were considered to investigate the appropriate drawbar power. Variations of the power requirement of the tractor-mounted radish collector were observed due to modifications of the design parameters. The required hydraulic power of the stem cutting conveyor, stem cutting blade, and transfer conveyor of the radish collector were 0.23 and 0.24, 0.18 and 0.19, and 0.19 and 0.22 kW under unloaded and loaded conditions, respectively. The maximum draft power was calculated as 0.89, 1.07, 1.25, and 1.61 kW at a 30° tilted angle for hard, firm, tilted, and sandy soil, respectively. The calculation showed 2.07 kW DC power was required for unfolding or folding the stem-cutting conveyor. A maximum power of 4.78 kW was prescribed for conducting the whole process of the tractor-mounted radish collector. The analysis of power introduced in this study will be helpful to select the appropriate design parameters for the successful development of a tractor-mounted radish collector.

PERFORMANCE OF AN OSCILLATING SUBSOILER IN BREAKIN HARD PAN

  • Bandalan, E.P.;Gupta, C.P.;Salokhe, V.M.;Niyamapa, T.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.1043-1052
    • /
    • 1993
  • Field experiments were conducted to determine the optimum combination of performance parameters of a single-shank, tractor-mounted oscillating subsoiler. Tests were conducted at frequencies of oscillation of 3.7 , 5.67, 7.58, 9.48 and 11.456Hz ; amplitudes of 18, 21, 23.5, 34 and 36.5 mm ; and forward speeds of 1.84, 2.19 and 3.42 kmph at moisture content close to the plastic limit of the soil. It was observed that there was a reduction in average draft but an a increase in average total power requirement for oscillating than non-oscillating subsoiling. The draft and power ratios were significantly affected by the forward speed, frequency and amplitude. Their combined interaction expressed in terms of the velocity ratio parameter( the ratio of peak tool velocity and forward speed) however has the strongest influence. At the same velocity ratio, the draft reduction and power increase were less at higher amplitude of oscillation . As the oscillating frequency is increased toward the soil resonance the draft requirement becomes less. For the field conditions tested. the optimum operation was obtained at an amplitude of 36.5mm, frequency of 9.48Hz and speed of 2.19 kmph with a draft ratio of 0.33 and a power ratio of only 1.24.

  • PDF

EMC Safety Margin Verification for GEO-KOMPSAT Pyrotechnic Systems

  • Koo, Ja-Chun
    • International Journal of Aerospace System Engineering
    • /
    • v.9 no.1
    • /
    • pp.1-15
    • /
    • 2022
  • Pyrotechnic initiators provide a source of pyrotechnic energy used to initiate a variety of space mechanisms. Pyrotechnic systems build in electromagnetic environment that may lead to critical or catastrophic hazards. Special precautions are need to prevent a pulse large enough to trigger the initiator from appearing in the pyrotechnic firing circuits at any but the desired time. The EMC verification shall be shown by analysis or test that the pyrotechnic systems meets the requirements of inadvertent activation. The MIL-STD-1576 and two range safeties, AFSPC and CSG, require the safety margin for electromagnetic potential hazards to pyrotechnic systems to a level at least 20 dB below the maximum no-fire power of the EED. The PC23 is equivalent to NASA standard initiator and the 1EPWH100 squib is ESA standard initiator. This paper verifies the two safety margins for electromagnetic potential hazards. The first is verified by analyzing against a RF power. The second is verified by testing against a DC current. The EMC safety margin requirement against RF power has been demonstrated through the electric field coupling analysis in differential mode with 21 dB both PC23 and 1EPWH100, and in common mode with 58 dB for PC23 and 48 dB for 1EPWH100 against the maximum no-fire power of the EED. Also, the EMC safety margin requirement against DC current has been demonstrated through the electrical isolation test for the pyrotechnic firing circuits with greater than 20 dB below the maximum no-fire current of the EED.

Energy Balance Analysis of Communication Satellite at Transfer Orbit (통신위성 전이궤도 전력운용 분석)

  • Choi J.D.;Seong S.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.189-192
    • /
    • 2003
  • Electrical power in satellite system should persistently satisfy specified power requirement even though that happen the failure of solar array string or battery cell during the mission operation. In this study, the solar array and battery of GEO Communication Satellite with 3kW capacity are designed, and energy balance analysis according to power operation mode are performed to meet specified power capacity at the transfer orbit

  • PDF

ESTIMATION OF REQUIRED CAPACITY OF SHUNT TYPE ACTIVE POWER FILTER WITH A THYRISTOR CONVERTER LOAD

  • Jeong, Seung-Gi;Kim, Dong-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.802-807
    • /
    • 1998
  • The main drawback of parallel type active power filters (APF) is the large capacity required for harmonic compensation. This paper evaluates the APF capacity requirement of harmonic/reactive power compensation for thyristor converter load. Theoretically achievable maximum power factor under partial load is evaluated. And it is shown that the APF capacity can be considerably reduced while slightly sacrificing the filtering performance by deliberately limiting the peak current of the APF.

  • PDF

Cooling Test of The HTS Power Cable (초전도케이블 냉각시험)

  • 염한길;고득용;홍용주;김익생;김춘동;김도형
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.295-297
    • /
    • 2003
  • Cryogenic systems is requirement for the operation of HTS power cables. In general, HTS power cables require temperature below 77K, a temperature that can be achieved from the liquid nitrogen or sub-cooled LN2. HTS power cable is needed for sufficient refrigeration to overcome its low temperature heat loading. This loading typically comes in two forms : (1) heat leaks from the surroundings and (2) internal heat generation. This paper is a explanation for the cooling test of 10m HTS power cable.

  • PDF

Ultrasonic Engancement of Flow in Clayey Sands (점토질 모래에서의 Ultrasonic을 이용한 투수성의 증진)

  • 이광열
    • Water for future
    • /
    • v.26 no.1
    • /
    • pp.63-69
    • /
    • 1993
  • Remediation technology becomes an issue in environmental engineering. The vibro-recovery technique is one of popular means to remove pollutants from contaminated soils and groundwater. Using Ultrasonic excitation in soil-fluid medium, it was found that removal efficiency in a mechanical effects was significant. In this paper, therefore, laboratory experiments were conducted on clayey sand soil columns using a probe-type ultrasonic processor. Ultrasonic treatment with simultaneous pumping enhances dislodgement of clay particles, and ultrasonic excitation reduced the proportions of finer particles and thus result in increased hydraulic conductivity significantly. Also, the results provided the changes in grain size distribution curve of the soil due to ultrasonic excitation. The results indicated that the maximum size of particles mobilized by Ultrasonic is about 0.004mm and particles in the size range from 0.04mm to 1.0mm were subjected to fracturing. The economic feasibility of Ultrasonic implementation is considered in power requirement of the generator and maintenance of the horn. At a specified amplitude of vibrations, the power requirement of the generator depends on overburden pressure of the horn, temperature and viscosity of fluid in the soil medium. For comparisons, the requirement of a one inch and two inch diameter horn sonicators are compared with the power required for pumping water from different depths.

  • PDF

The Study on Lighting Load of Lower-part in Apartment Houses (공동주택 저층부의 조명부하에 관한 연구)

  • Lee, Dong-Wook;Lee, Jun-Gi;Lee, Gab-Taek;Kim, Yong-Tae;Lee, Kyung-Hee
    • Journal of Power System Engineering
    • /
    • v.20 no.1
    • /
    • pp.63-68
    • /
    • 2016
  • The study is arranged in the form of plate-shaped in the Apartment Houses with placed at right angles. After examined the daylight environment and the indoor illumination in this form of Apartment Houses, in order to improve the daylight environment of the lower floors, I examined the daylight environment. In order to match the indoor illumination, as a standard illumination 400lx, I examine the necessary lighting energy based on the direction and time for the different parts in the Apartment Houses, As the first floor, the lowest power requirement appeared to the South(457W), and the most power requirement appeared to the East(843W).