• 제목/요약/키워드: Power requirement

검색결과 1,004건 처리시간 0.031초

상정사고를 고려하는 최적 조류 계산의 분산 병렬 처리 기법에 관한 연구 (An Efficient Distributed Parallel Processing Method in Security Constrained Optimal Power Flow)

  • 김진호;허돈;박종근;김발호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.997-999
    • /
    • 1998
  • An operationally secure power system is one low probability of blackout or equipment damage. The power system is needed to maintain a designated security level at minimum operating cost. The inclusions of security make power system problem complex. But, because security and optimality are normally conflicting requirement, the separate treatments of both are inappropriate. So, a unified hierarchical formulation is needed. In this paper, the overview of security constrained optimal power flow (SCOPF) is presented and an introduction of parallel distributed formulation to SCOPF is also presented.

  • PDF

연료전지 축전지 하이브리드 동력원의 접속 특성 분석 (Load Analysis of the FuelCell/Battery Hybrid Power System)

  • 이봉도;이원용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3081-3083
    • /
    • 2000
  • Fuel cell/battery hybrid power systems were studied to develop high efficient zero-emission fuel cell electric vehicles, Fuel cells were used as an auxiliary energy source and batteries were used as a transient power source. The fuel cell system is used to supply the average power demand. Dynamic response of the hybrid systems was simulated using PSPICE program and also tested experimentally, The results can be used to design the interface module and to determine the power requirement between the fuel cell unit and the battery pack.

  • PDF

전력변환장치의 고조파 영향 및 연구동향 (Harmonic Effects and Consideration in Power Converter and Component)

  • 조성준;김태완;우명호;서광덕
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.467-470
    • /
    • 2001
  • Power electronic converters generate the harmonic voltage and current, and these harmonics have the harmful effects on the various components. For example, passive components such as capacitor and inductor, transformer, motor and other components are mainly affected in the power electronic system. Thus, the design and manufacturing of the power converters, which have the harmonic-free or mitigation strategies, are required. In particular, the lifetime and durability of these components are main requirement for enhancing the overall stability of the system. So, in this paper, the harmonics-related problems to the neighbouring components and mitigation research trends are presented.

  • PDF

Hybrid Sinusoidal-Pulse Charging Method for the Li-Ion Batteries in Electric Vehicle Applications Based on AC Impedance Analysis

  • Hu, Sideng;Liang, Zipeng;He, Xiangning
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.268-276
    • /
    • 2016
  • A hybrid sinusoidal-pulse current (HSPC) charging method for the Li-ion batteries in electric vehicle applications is proposed in this paper. The HSPC charging method is based on the Li-ion battery ac-impedance spectrum analysis, while taking into account the high power requirement and system integration. The proposed HSPC method overcomes the power limitation in the sinusoidal ripple current (SRC) charging method. The charger shares the power devices in the motor inverter for hardware cost saving. Phase shifting in multiple pulse currents is employed to generate a high frequency multilevel charging current. Simulation and experimental results show that the proposed HSPC method improves the charger efficiency related to the hardware and the battery energy transfer efficiency.

Distributed Adaptive Virtual Impedance Control to Eliminate Reactive Power Sharing Errors in Single-Phase Islanded Microgrids

  • Hoang, Tuan V.;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.120-121
    • /
    • 2017
  • This paper proposes an enhanced distributed generation (DG) unit with an adaptive virtual impedance control approach in order to address the inaccurate reactive power sharing problem. The proposed method can adaptively regulate the DG virtual impedance, and the effect of the mismatch in feeder impedances is compensated to share the reactive power accurately. The proposed control strategy is fully distributed and the need for the microgrid central controller is eliminated. Furthermore, the proposed method can be directly implemented without requirement of pre-knowledge of the feeder impedances. Simulations are performed to validate the effectiveness of the proposed control approach.

  • PDF

소내부하 운전시의 전기계통 과도협상 분석 (Transient Study of Electrical Power System on House Load Operation)

  • 임진옥;조성돈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.746-748
    • /
    • 1996
  • House load operation (HLO) is the Willy of a plant to continue to operate while completely separated from the transmission system. HLO capability is recently adopted as basic design requirement for nuclear power plants, since HLO capability increases the plant availability and power system reliability. However, HLO results in the voltage and frequency transients to motors and pumps. This paper presents the computer simulation results such as the transient speeds, voltages, and control system responses of turbine/g enerator during HLO. This paper also suggests the plant design features required for HLO capability and the transient speed/vlitage limits caused by HLO.

  • PDF

전력용 통신설비 신뢰도 산출 기법 연구 (A Study on the Reliability Evaluation Methodology of Power Telecommunication Facilities)

  • 이원태;김관호;김요희;이범석;우희곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.470-472
    • /
    • 1993
  • Nowadays, according to gradual progress of the information oriented society, it is being increase rapidly that social requirement for the high quality and stability of electric power supply. Therefore, for the sake of expansion of the various power system and reasonable operation and administration, there are some growing need for telecommunication system that will operate in high dependability performance and expansion by much. But beause of unestablished reliability analysis and evaluation methodology for power telecommunication system, it could not have a reasonable planning for the purpose of improving dependability performance on telecommunication system. The object of this study is to construct reasonable methodology of reliability evaluation fur the efficient power telecommunication facility administration.

  • PDF

100kW급 보조동력장치용 압축기 성능시험 (Performance test for the compressor of 100kW APU)

  • 임병준;차봉준;양수석;이경진;백기영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.655-660
    • /
    • 2001
  • The performance test of a centrifugal compressor for APU(Auxiliary Power Unit) which is developed by the collaborative research of KARI and Samsung TechWin has been conducted. The investigated compressor consists of a curved inlet, a centrifugal impeller, a channel diffuser and a plenum chamber. The experiments were carried out in an open-loop centrifugal compressor test rig driven by a turbine. For three different diffusers, overall performance data were obtained at 80%, 90% and 97% of design speed. For the initially designed wedge-type diffuser, test results showed that the compressor was operated at a higher mass flow rate than the design requirement. By reducing the diffuser throat area, the compressor operating range was shifted to lower mass flow rate range. The test result of redesigned wedge-type diffuser showed high pressure loss. To reduce the diffuser loss, diffuser inlet radius was increased and airfoil-type of diffuser was adopted. This airfoil-type diffuser showed reasonal results in terms of design requirement.

  • PDF

Training Requirements for Control Room Operators of an Advanced Nuclear Power Plant

  • Park, Hong Joon;Park, Geun Ok;Kim, Sa Kil;Byun, Seong Nam
    • 대한인간공학회지
    • /
    • 제32권1호
    • /
    • pp.107-115
    • /
    • 2013
  • Objective: The aim of this study is to identify the training requirements of new nuclear power plant by a comprehensive literature review. Background: The design of instrumental and control systems for New NPP is applied fully digitalized systems. For example, soft-control, large display panels(LDP), and an advanced alarm system were applied to the APR-1400 or SMART. Method: The NUREG-0711 and international guideline of training program was analyzed from the following four phases of SAT(Systemic Approach to Training): Analysis, Design, Development, Implementation and Evaluation. Results: To identify the requirement of training program, 'Feedback' phase was considered and each phase of SAT was classified. Conclusion: A more systematic requirement of training program is needed which considers the computerized system was applied to the new NPP. Application: The results of the publishing can be useful for standardization of the systematic training program for the operators of NPP.

Quality of Service Tradeoff in Device to Device Communication Underlaid Cellular Infrastructure

  • Boabang, Francis;Hwang, Won-Joo
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.591-593
    • /
    • 2016
  • Device-to-device (D2D) communications underlaid cellular infrastructure is an competitive local area services technology to promote spectrum usage for next generation cellular networks. These potential can only be tap through efficient interference coordination. Previous works only concentrated on interference from D2D pairs whiles interference from CUs to D2D pairs were neglected. This work focus on solving uplink interference problem emanating from multiple CUs sharing its resource with multiple D2D pairs. The base station (BS) acting as a supervisor selfishly institute a pricing scheme to manage the interference it experience from D2D pairs based on its Quality of service (QoS) requirement. D2D pairs following the supervisor make power allocation decisions considering the price from the BS in a non-cooperative game fashion. In order for the D2D pairs to also meet their QoS requirement, they suggest a price to the BS called discount price which reflects the interference they receive from the CUs. Finally, we analyze the proposed approach.

  • PDF