• 제목/요약/키워드: Power reduction

검색결과 4,705건 처리시간 0.046초

Three-Phase Hybrid Shunt Filters for Power Quality Improvement

  • Bhuvaneswari, G.;G.Nair, Manjula
    • Journal of Power Electronics
    • /
    • 제7권3호
    • /
    • pp.257-264
    • /
    • 2007
  • Active power filters can be cost-effective for use in practical systems with the insertion of a few passive elements in shunt or series configuration. The resulting hybrid filters can be designed to provide dominant lower order harmonic elimination and reactive power support by the passive elements so that the burden on the active filter counterpart is reduced. In this paper, the rate reduction in the shunt active filter is estimated when it is connected in parallel with suitable passive tuned harmonic filters. The active filtering system is based on an appropriate control scheme. The simulation and the experimental results of the shunt active filter, along with the estimated value of reduction in rating, show that the hybrid shunt filtering system is quite effective in compensating for the harmonics and reactive power, in addition to being cost-effective.

회생에너지를 이용한 도시철도 전력관리시스템 구축에 관한 연구 (Study for Power Management System using Regenerative Energy in Electric Railway Systems)

  • 이한상;조윤성;김형철;정호성
    • 전기학회논문지
    • /
    • 제63권1호
    • /
    • pp.191-196
    • /
    • 2014
  • For the large scale of electricity consumer, since the price for the electricity consumption depends on the peak power, the issue for peak power reduction have been being studied widely. Electric railway systems, which is one of the most representative large scale of loads, also has assignment to reduce the peak power since they have high peak power and low energy consumption load characteristics. In the aspect of the economic operation through reduction of peak power, this paper proposes a novel algorithm for power management system in electric railway systems using energy storage.

Innovative Nuclear Power Plant Building Arrangement in Consideration of Decommissioning

  • Choi, Won-Jun;Roh, Myung-Sub;Kim, Chang-Lak
    • Nuclear Engineering and Technology
    • /
    • 제49권3호
    • /
    • pp.525-533
    • /
    • 2017
  • A new concept termed the Innovative Nuclear Power Plant Building Arrangement (INBA) strategy is a new nuclear power plant building arrangement method which encompasses upfront consideration of more efficient decommissioning. Although existing decommissioning strategies such as immediate dismantling and differed dismantling has the advantage of either early site restoration or radioactive decommissioning waste reduction, the INBA strategy has the advantages of both strategies. In this research paper, the concept and the implementation method of the INBA strategy will be described. Two primary benefits will be further described: (1) early site restoration; and (2) radioactive waste reduction. Several other potential benefits will also be identified. For the estimation of economic benefit, the INBA strategy, with two primary benefits, will be compared with the immediate dismantling strategy. The effect of a short life cycle nuclear power plant in combination with the INBA strategy will be reviewed. Finally, some of the major impediments to the realization of this strategy will be discussed.

접착형 $MoS_2$고체윤활피막이 코팅된 감속기의 동력전달효율과 소음 특성에 관한 실험적 고찰 (An Experimental Study on the Power Transmission Efficiency and Frictional Noise of $MoS_2$-Bonded-Film Coated Reduction Gears)

  • 윤의성;공호성;한홍구;오재응
    • Tribology and Lubricants
    • /
    • 제12권3호
    • /
    • pp.107-114
    • /
    • 1996
  • MoS$_{2}$ bonded film was applied to reduction gears, and its lubricating properties were experimentally evaluated in terms of the power transmission efficiency and the frictional noise with a dynamo-typed gear test rig. Tests were performed in both oil lubrication and dry condition where the rotating velocity and loading torque were varied. In dry condition, MoS$_{2}$ bonded films effected the power transmission efficiency to increase about 5%, and the frictional noise level to decrease about 6 dB under the test operating conditions. It well proved that MoS$_{2}$ bonded films were a very effective solid lubricant for reduction gears. In oil lubricating conditions, the frictional properties of the coated gears were mainly governed by the lubricating oil, and lubricating effects of MoS2 bonded films were not evident. The result suggested that lubricating effect of MoS$_{2}$ bonded films would be limited to prevent a damage of reduction gears in the initial run when they were used in oil lubrication conditions.

테스트 데이터와 전력소비 단축을 위한 저비용 SOC 테스트 기법 (Low Cost SOC(System-On-a-Chip) Testing Method for Reduction of Test Data and Power Dissipation)

  • 허용민;인치호
    • 대한전자공학회논문지SD
    • /
    • 제41권12호
    • /
    • pp.83-90
    • /
    • 2004
  • 본 논문은 SOC의 테스트 데이터 압축과 전력소비를 단축시키기 위한 효율적인 스캔 테스트 방법을 제안한다. 제안된 테스트 방법은 deterministic 테스트 데이터와 그 출력응답을 분석하여 출력응답의 일부분이 차기에 입력될 테스트 데이터로 재사용될 수 있는지를 결정한다. 실험결과, 비압축된 deterministic 입력 테스트 데이터와 그 응답간에 높은 유사도가 있음을 알 수 있다. 제안된 테스트 방법은 ISCAS'89 벤치마크 회로를 대상으로 소요되는 클럭 시간을 기준으로 평균 29.4%의 전력소비단축과 69.7%의 테스트 데이터 압축을 가져온다.

Prototype of a Peak to Average Power Ratio Reduction Scheme in Orthogonal Frequency Division Multiplexing Systems

  • Varahram, Pooria;Ali, Borhanuddin Mohd;Mohammady, Somayeh;Reza, Ahmed Wasif
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권6호
    • /
    • pp.2201-2216
    • /
    • 2015
  • Peak to average power ratio (PAPR) is one of the main imperfections in the broadband communication systems with multiple carriers. In this paper, a new crest factor reduction (CFR) scheme based on interleaved phase sequence called Dummy Sequence Insertion Enhanced Partial Transmit Sequence (DSI-EPTS) is proposed which effectively reduces the PAPR while at the same time keeps the total complexity low. Moreover, the prototype of the proposed scheme in field programmable gate array (FPGA) is demonstrated. In DSI-EPTS scheme, a new matrix of phase sequence is defined which leads to a significant reduction in hardware complexity due to its less searching operation to extract the optimum phase sequence. The obtained results show comparable performance with slight difference due to the FPGA constraints. The results show 5 dB reduction in PAPR by applying the DSI-EPTS scheme with low complexity and low power consumption.

풍력터빈 타워 하중 저감을 위한 타워 댐퍼 게인 스케줄링 알고리즘 설계 (Design of Tower Damper Gain Scheduling Algorithm for Wind Turbine Tower Load Reduction)

  • 김철진;김관수;백인수
    • 한국태양에너지학회 논문집
    • /
    • 제38권2호
    • /
    • pp.1-13
    • /
    • 2018
  • This paper deals with the NREL (National Renewable Energy Laboratory) 5-MW reference wind turbine. The controller which include MPPT (Maximum power point tracking) control algorithm and tower load reduction control algorithm was designed by MATLAB Simulink. This paper propose a tower damper algorithm to improve the existing tower damper algorithm. To improve the existing tower damper algorithm, proposed tower damper algorithm were applied the thrust sensitivity scheduling and PI control method. The thrust sensitivity scheduling was calculated by thrust force formula which include thrust coefficient table. Power and Tower root moment DEL (Damage Equivalent Load) was set as a performance index to verify the load reduction algorithm. The simulation were performed 600 seconds under the wind conditions of the NTM (Normal Turbulence Model), TI (Turbulence Intensity)16% and 12~25m/s average wind speed. The effect of the proposed tower damper algorithm is confirmed through PSD (Power Spectral Density). The proposed tower damper algorithm reduces the fore-aft moment DEL of the tower up to 6% than the existing tower damper algorithm.

효모를 사용한 한지직물의 천연인디고 염색 : 효모농도와 반복염색 효과 (Natural Indigo Dyeing of Hanji Fabric using Baker's Yeast: Effect of Yeast Concentration and Repeat Dyeing)

  • 손경희;신윤숙;류동일
    • 한국염색가공학회지
    • /
    • 제33권4호
    • /
    • pp.191-201
    • /
    • 2021
  • In this study, an eco-friendly indigo reduction system(scale up reduction, use of buffer solution, and pH control) using baker's yeast(Saccharomyces cerevisiae) was applied for natural indigo(Polygonum tinctorium) dyeing of Hanji fabric and Hanji-mixture fabric(Hanji/Cotton, Hanji/Silk). The effect of concentration of baker's yeast, repeat dyeing, and bath reuse was investigated in terms of dye uptake indicating reduction power. And the oxidation-reduction potential(ORP) was monitored. We also evaluated color properties and colorfastness according to the color strength. The yeast concentration did not significantly affect the maximum reduction power. However, the highest yeast concentration was effective in improving the initial dye uptake, and its the reduction retention power was the most excellent. Even on the last reduction day, the effect of increasing the dye uptake by repeat dyeing was observed. And it was confirmed that the reduction bath could be reused for up to 30 days by supplementing yeast at the end of reduction. For all the fabrics used, deeper and darker PB color were obtained by repeat dyeing. As dyeing was repeated, purplish tint got stronger on the Hanji/Silk fabric compared to other fabrics. Regardless of the composition of Hanji fabrics and color strength, washing and dry cleaning fastness were relatively good with above rating 4-5, and fastness to rubbing and light were acceptable with a rating 3-4 ~ 4-5. The eco-friendly natural indigo dyeing process using niram and baker's yeast would offer global marketability and diversity of Hanji product as a sustainable high value-added material.

고압 전기설비 부분방전시험을 위한 노이즈 저감방안 (A Novel Noise Reduction Method for Measuring Partial Discharge in High Voltage Electric Machinery)

  • 이영준;박광하;최형주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2021_2022
    • /
    • 2009
  • Partial discharges(PD) is a important factor to evaluate the insulation state in high voltage electric machinery. However, measuring PD under the circumstances of power plant is occasionally impossible due to the relatively high magnitude of noise which is emanated from the operating machinery. In some case, the instrument measuring PD can not even perform a calibration that initializes tools and enhance the accuracy. This paper presents that we devised a noise reduction method and demonstrated the usefulness in acquiring reliable PD signals. We attached a series of filter and transformer at the input of power source of the instruments which refrains high noise signals from incoming to the instruments. We experimented the efficiency of noise reduction applying the device into the Dangjin Power Plant and Factory. As a result of testing with the filter and transformer, we can easily calibrate the PD signal compared to the case without the device. Additionally, we can detect the small PD signal which was unperceived with a normal device.

  • PDF