국제표준 ISO/IEC 15288 기반의 경량전철 전력시스템 검증 프로세스에 관한 연구 (A study on Verification Process for LRT's Power Supply System Based on the ISO/IEC 15288)

  • 최원찬;배준호;허재훈;이상근;한석윤
    • 시스템엔지니어링학술지
    • /
    • 제9권1호
    • /
    • pp.47-53
    • /
    • 2013
  • The object of this study is to define systematically for outputs of Verification Process among the system life cycle process based on ISO/IEC 15288 for power supply system, which is one of the importance sub-systems to configure the LRT system. Furthermore, to prevent various problem in advance that can occur in the Transition LRT's power supply to be completed Integration. For this purpose, traceability of verification requirement and outputs. should be managed to use verification for system requirement and data processing tool. by system engineering techniques of system life cycle process based on ISO/IEC 15288 to LRT system.

한전 765 kV 2회선 송전선로의 전기환경장애 특성 (Environmental Impact on the KEPCO 765-kV Double Circuit Transmission Line)

  • 이동일;신구용;김정부
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권2호
    • /
    • pp.117-126
    • /
    • 1999
  • The environmental impact of the KEPCO 765-kV transmission line was studied using a full scale test line in order to develop the design technology. Therefore this paper describes an environmental design summary of the audible noise, hum noise, wind noise, radio interference, TV interference and electric field measurement from the KEPRI 765-kV double circuit transmission test line with a bundle of $6-480mm^2$ conductors per phase. The analysis of the test results shows that 6-Rail and 6-Cardinal conductors bundle satisfy the audible noise criterion & TV interference under the stable rainy weather condition and the radio interference level under the fair weather. And the other items are also agreed with the design level criterion for KEPCO 765-kV transmission line.

  • PDF

비접지 DC 급전계통에서 전류형 지락보호계전기의 사용 (New Ground Fault Protective Relay in DC Traction Power System)

  • 정상기;백남욱;김연수;이성혁;이한민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1297-1302
    • /
    • 2004
  • In DC power distribution system for urban rail transits potential relay, 64P, is used to detect the ground faults. The problem with this 64P is that though it detects the ground fault it cannot identify the faulted region. Therefore the faulted region cannot be isolated properly. It could results in power loss of the trains on the healthy regions and the safety of the passengers in the trains could be affected adversely. A new ground fault protective relaying scheme that can identify the faulted region is presented in this paper. The new concept uses the current differential scheme and the permissive scheme to identify the faulted region correctly. A device with similar characteristic to the arrestor is adapted to use the current relay for the ground fault detection. The role of the device is to block the ground leakage current in normal operating condition and enable the ground fault current to flow in ground fault condition. The algorithm of the new relay and the effect of the newly adapted device in the new relaying scheme are discussed.

  • PDF

집전 전압 향상을 위한 교류급전시스템의 단권변압기 구성 검토 (Investigation of Autotransformer Configuration to Enhance Collecting Voltage in Train)

  • 김주락;김정훈
    • 한국철도학회논문집
    • /
    • 제13권1호
    • /
    • pp.65-70
    • /
    • 2010
  • 국내 교류 급전시스템은 단권변압기를 이용한 방식을 채택하고 있다. 이 시스템은 흡상 변압기를 이용한 방식보다 급전 거리가 긴 장점이 있으나 최근 대용량 차량의 도입과 시격이 짧아짐에 따라 전압 강하에 대한 대응이 시급한 실정이다. 본 논문에서는 교류 급전시스템의 전압강하 해소를 위하여 SVC와 같은 추가 설비의 도입 없이 보조 급전구분소 포는 급전구분소의 단권변압기를 이용한 시스템을 제안한다. 열차가 집전받는 전차선과 레일간의 전압을 높이기 위하여 열차가 위치한 인근의 단권변압기의 권선비를 현재 1:1에서 N:1로 바꾸는 것이다. 이렇게 하면 부하에서 공급받는 전압이 높아져 열차의 효율 향상 및 부하전류의 감소 등의 효과를 얻을 수 있을 것이다.

A Study on a Catenary Impedance Estimation Technique using Boosting Current Compensation Based on Current Division Characteristics of an AT Feeding System

  • Jung, Hosung;Kim, Hyungchul;Chang, Sang-Hoon;Kim, Joorak;Min, Myung-Hwan;An, Tae-Pung;Kwon, Sung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1370-1376
    • /
    • 2015
  • Generally, an autotransformer(AT) feeding system consists of double tracks, up and down, with the trolley wire and feeder wire of the up and down tracks connected in the sectioning post(SP). Consequently, load current or fault current flows on two tracks based on catenary impedance characteristics, making it difficult to estimate catenary impedance accurately. This paper presents a technique for the estimation of catenary impedance using boosting current compensation based on the current division characteristics of an AT feeding system to improve the operation performance of impedance relay. To verify the technique, we model an AT feeding system through a power analysis program (PSCAD/EMTDC) and simulate various operation and fault conditions. Through the simulation, we confirmed that the proposed technique has estimated catenary impedance with a similar degree of accuracy to the actual catenary impedance

지하철 터널 구간 강체가선 방식의 특성분석 (Analysis of Overhead Rigid Conductor Line for the Subway tunnel section)

  • 임금광;창상훈;김왕곤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.493-499
    • /
    • 2003
  • Railroad, a superior mode of public transportation provides safe, efficient, speedy, comfortable and economical service, has fundamentally different characteristics from airplanes, ships and cars. Among the unique characteristics of a railroad is the fact that it operates on fixed track with multiple car trains. The subway system was first selected as the best solution to difficult automobile traffic conditions and environmental problems. Seoul subway no.1line (Jongno line) was opened for service on August 15, 1974. Seoul city has completed and now operates eight subway lines (286.7km) since 1974. At present the subways operate in Busan, Daegu and Incheon city, and are under construction in Gwangju and Daejeon city. The power source for subway trains has been electricity since 1896, and power supply systems are the third rail type and/or the catenary system. The typical catenary system is the rigid bar type. R-bar and T-bar are used in the rigid bar type of catenary system, and the two types of R-bar and T-bar are uesd in Korea also. R-bar is used only for AC 25kV power supply and T-bar for DC 1,500V. From 30 years of subway experience I would like to suggest the most economic catenary system to ensure of safety, reliability and expediency for the railway lines to be constructed and the forthcoming replacement due to the life cycle after studying and analysing the characteristics, advantages and disadvantages of R-bar and T-bar.

  • PDF

6단자망 회로모델을 이용한 전기철도 급전시스템의 고조파 해석 (Harmonic Analysis for Traction Power Supply System Using Four-Port Network Model)

  • 창상훈;오광혜;김주락;김정훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권6호
    • /
    • pp.255-261
    • /
    • 2002
  • Recently, traction motors in trains are supplied with single phase a.c. power. After this power is converted to d.c. power, it is inverted to three phase power to operate traction motors. As going through the process of the conversion, harmonic current is generated in train. The method of conventional analysis on harmonics, studied by RTRI, is modeled with equivalent circuit of ac AT-fed electric railroad system using by the distributed constant circuit. However, this circuit as two-port network model has some difference in comparison with real system. The reason why the conventional method is different from the real system is that the conventional method dose not include three conductor groups, that is catenary, rail, and feeder, and admittance between the conductors for line capacitance. Therefore, this method has a little error. This paper proposes new method to more effectively estimate Harmonic current. In this method, numerous components in electric railway are categorized and each component is defined as a four- port network model. The equivalent circuit for the entire power supply system is also described into a four-port network model with connections of these components. In order to evaluate the efficiency and the accuracy of a proposed method, it is compared with values measured in Kyung-Bu high speed line and ones calculated by the conventional method.

Analysis of Z-Source Inverters in Wireless Power Transfer Systems and Solutions for Accidental Shoot-Through State

  • Wang, Tianfeng;Liu, Xin;Jin, Nan;Ma, Dianguang;Yang, Xijun;Tang, Houjun;Ali, Muhammad;Hashmi, Khurram
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.931-943
    • /
    • 2018
  • Wireless power transfer (WPT) technology has been the focus of a lot of research due to its safety and convenience. The Z-source inverter (ZSI) was introduced into WPT systems to realize improved system performance. The ZSI regulates the dc-rail voltage in WPT systems without front-end converters and makes the inverter bridge immune to shoot-through states. However, when the WPT system is combined with a ZSI, the system parameters must be configured to prevent the ZSI from entering an "accidental shoot-through" (AST) state. This state can increase the THD and decrease system power and efficiency. This paper presents a mathematical analysis for the characteristics of a WPT system and a ZSI while addressing the causes of the AST state. To deal with this issue, the impact of the system parameters on the output are analyzed under two control algorithms and the primary compensation capacitance range is derived in detail. To validate the analysis, both simulations and experiments are carried out and the obtained results are presented.

승강기 Car용 고속응성 배터리 충전시스템에 적합한 제어알고리즘 (A Control Algorithm Suitable for High-speed Response Battery Charging System for Elevator Car)

  • 이정환;황보찬;박성준;박성미;고재하
    • 한국산업융합학회 논문집
    • /
    • 제25권6_2호
    • /
    • pp.1071-1081
    • /
    • 2022
  • As the demand for high-rise buildings increases, the demand for high-speed elevators is also increasing. In order to make a high-speed elevator, a method is needed to reduce the weight of the elevator's components, which is a constraint on the increase in speed. As a measure to reduce the weight, it is possible to remove the traveling cable for power and signal supply. Since the weight of the traveling cable varies depending on the position of the carriage, it is difficult to compensate the weight using the counter weight. The power supply is a structure in which a brush-rail type power input terminal is installed in the elevator hoistway to receive power in a contact-type manner while the carriage is moving. If a small-capacity ESS is installed in a passenger car, power can be supplied uninterruptedly inside the passenger car. A small-capacity ESS charging system to be applied to such an elevator system is required to perform several functions. First, the passenger Car must be able to charge as much as possible even during high-speed operation. A control algorithm with high responsiveness is required because charging starts and ends repeatedly by the partially installed input power stage. In addition, if the input-side line impedance is large due to the structure of the system and the response characteristic is increased, the stability of the system may be lowered. Accordingly, in this paper, we propose a control algorithm that has a stable steady-state output while having a fast response in a transient state. To verify the proposed control algorithm, simulation was conducted using PSIM, and the performance of the controller was verified by manufacturing a prototype buck conveter charger.

PRML Read Channel용 고효율, 저전력 FIR 필터 칩 (Highly Efficient and Low Power FIR Filter Chip for PRML Read Channel)

  • Jin Yong, Kang;Byung Gak, Jo;Myung Hoon, Sunwoo
    • 대한전자공학회논문지SD
    • /
    • 제41권9호
    • /
    • pp.115-124
    • /
    • 2004
  • 본 논문은 고효율, 저전력을 갖는 PRML 디스크 드라이브 읽기 채널용 6비트, 8탭의 FIR 필터 칩을 제안한다. 제안된 필터는 병렬처리 구조를 채택하고 있으며 4단의 파이프라인으로 구성되어 있다. 곱셈 연산을 위하여 수정 부스 알고리즘을 사용하였으며 덧셈 연산을 위하여 압축회로 로직을 사용하였다. 전력 소모를 줄이기 위하여 CMOS 패스-트랜지스터 로직을 사용하였으며 싱글-레일 로직을 이용하여 칩의 면적을 감소시켰다. 제안된 필터는 실제 칩으로 구현되었으며 3.3V 전원을 공급하여 100MHz에서 120mV의 전력을 소비하고 1.88×1.38 ㎟의 면적을 차지한다. 구현된 필터는 유사 선폭의 공정을 사용한 기존구조에 비해 약 11.7%의 전력이 감소하였다.