• 제목/요약/키워드: Power quality measurement

검색결과 349건 처리시간 0.028초

HFPD 검출법을 이용한 지중 케이블 실선로 진단 (Diagnosis of power cable system based on the HFPD detection at on-site)

  • 이전선;김충식;이동근;공충호;석광현;이경욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.97-100
    • /
    • 2004
  • HFPD(High Frequency Partial Discharge) measurement has been widely performed to diagnosis of cable system in the world although Korea just begin. The efficiency of measurement has been reported and proved by many researchers who are engaged in the diagnosis of high power apparatus. LG Cable has investigated the technology of diagnosis for cable system by means of PD measurement for 10 years. In this paper, PD measurement with portable device was performed to evaluate the quality of the 154kV transmission line and the 22.9kV XLPE cable line. Test results are shown that the HFPD detection technology is very attractive for the diagnosis of power cable system by high detection sensitivity at on-site.

  • PDF

고속전철 급전계통에서의 고조파 측정 방안 (Scheme for Harmonics measurement in feeding System of high speed railroad)

  • 최흥관;황치우;윤재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.304-307
    • /
    • 1998
  • High speed railway is under construction from Seoul to Pusan. A traveling train is large single phase load that consumes 14MW power in feeding system of high speed railroad. In this paper, measurement scheme and method of power system harmonics which are generated from those loads in railroad supply system are described. This measurement scheme will be used as a first step to pave a way to power quality management due to harmonic distortion by the highspeed rail way.

  • PDF

Power Quality Monitoring System with a New Distributed Monitoring Structure

  • Won, Dong-Jun;Chung, Il-Yop;Kim, Joong-Moon;Ahn, Seon-Ju;Moon, Seung-Il;Seo, Jang-Cheol;Choe, Jong-Woong
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권4호
    • /
    • pp.214-220
    • /
    • 2004
  • Power quality monitoring is the cornerstone for power quality analysis, diagnosis and improvement. The measurement of power quality (PQ) evolves from instantaneous metering to continuous monitoring. Furthermore, recent technologies enable us to construct more flexible, reliable, rapid and economical power quality monitoring system (PQMS). Therefore, this paper presents an improved PQMS with a new distributed monitoring structure. The proposed PQMS consists of a PQ meter, PQ analyzer and GUI. The PQ meter only collects raw data and the PQ analyzer performs power quality analysis. It has several advantages compared to conventional structures in economic efficiency, modularity, speed, etc. PQ monitoring algorithms to catch steady-state trends and to detect PQ events are also adapted to the proposed structure. Using the proposed structure and monitoring algorithm, a prototype PQMS is constructed and real-time testing is performed.

성악 전공 학생의 가칭 시 음성의 SPR(Singing Power Ratio)에 관한 연구 (A Study of the SPR (Singing Power Ratio) on the Singing Voice in Singing Students)

  • 조성미;정옥란;이상욱
    • 음성과학
    • /
    • 제11권4호
    • /
    • pp.121-127
    • /
    • 2004
  • This study attempted to provide a spectrum analysis for quantitative evaluation of singing voice quality of singing students rather than the presence or absence of the singer's formant. The regression analysis was used to analyse the relationship between ringing quality, SPR, and SPP of singing voice of college student subjects majoring in music. This study measured singing. power ratio (SPR) in 41 singing students. Digital audio recordings were made in sung vowels for acoustic analyses. Each sample was judged by 1 experienced singing teacher and 4 voice pathologists on one semantic bipolar 7-point scales (ringing-dull). The results showed that the SPR and SPP had significant correlations with ringing quality. The SPR had a significant relationship with ringing quality on singing voice in singing students. The SPR can be an important quantitative measurement for evaluating singing voice quality.

  • PDF

Compensation Strategy to Eliminate the Effect of Current Measurement Offsets in Grid-Connected Inverters

  • Lee, Chang-Hee;Choi, Jong-Woo
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.383-391
    • /
    • 2014
  • For the digital control of systems such as grid-connected inverters, measuring inverter output currents accurately is essential. However, current measurement offsets are inevitably generated by current measurement paths and cause DC current components in real inverter output currents. Real inverter output currents with DC components cause the DC-link capacitor voltage to oscillate at the frequency of a utility voltage. For these reasons, current measurement offsets deteriorate the overall system performance. A compensation strategy to eliminate the effect of current measurement offsets in grid-connected inverters is proposed in this study. The validity of the proposed compensation strategy is verified through simulations and experiments. Results show that the proposed compensation strategy improves the performance of grid-connected inverters.

전기설비의 고조파 분석을 위한 측정 시스템의 개발 (Development of Measurement System for Harmonic Analysis of Electric Equipment)

  • 유재근;이상익;전정채
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.259-261
    • /
    • 2002
  • Recently, according to the spread of semiconductor applied technology like motor speed control contrivance, power conversion installation and so on, harmonic ingredients occurred in switching operation flow into a distribution system and increase voltage distortion of distribution system and bring on obstacles like damage, lowering of capability, false operation and so on of various electrical installation. So, in order to consider a countermeasure to limit occurrence quantity of harmonic source, harmonic interception and others, precision measurement and analysis on voltage, current, power, power factor, the each ingredient of harmonic order, the percentage of total harmonic distortion and so forth are needed. In this paper monitoring system to measure and analyze power quality connected with power harmonics was developed and it's performance is verified by measuring and analyzing three-phase voltage and current of R, S, T in the three-phase and four-wire system using the developed measurement system.

  • PDF

IEEE 1459-2010 규격의 정의를 이용한 다중 입력 채널을 갖는 전력 감시 시스템 (Power Monitoring System with Multiple Input Channels Using the Definition of IEEE Standard 1459-2010)

  • 전정채;오훈
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.3100-3106
    • /
    • 2014
  • 본 논문에서는 전력 시스템의 전원 및 부하 측을 동시에 감시가 가능한 다 채널(전압 8채널, 전류 10채널) 전력 측정 시스템을 개발하였다. 제안된 시스템은 전력품질과 관련된 규정인 IEEE 1459-2010의 정의를 사용하여 전력 성분을 계산하는 신호처리 알고리즘을 기반으로 TMS320C42 DSP를 이용하여 개발하였다. 개발된 시스템은 표준 전원 공급 장치를 이용하여 그 성능 시험을 실시하였고, 그 결과 측정오차는 0.2% 이하로 나타났다. 또한 제안된 시스템을 3상 4선식 전력시스템에 설치하여 실증 시험을 실시하여 그 성능을 입증하였다. 제안된 시스템은 상업 및 산업용 전력 시스템에 적용하여 동시에 다 채널로 전력을 측정 및 분석함으로써 전력품질과 관련된 다양한 문제를 줄일 수 있을 것이다.

DSP기반 3상 전력품질 분석시스템 (A DSP based Three Phase Power Quality Analyzer)

  • 정영국;김우용;조재연;임영철
    • 전력전자학회논문지
    • /
    • 제6권4호
    • /
    • pp.362-368
    • /
    • 2001
  • 본 연구는 전력품질을 평가할 수 있는 DSP기반 3상 전력품질 분석시스템의 국산화 개발을 목표로 하고 있다. 전력분석 알고리즘은 시간영역의 상관함수 이론을 사용하였고, 독립형 TMS320C31 DSP 보드에 의해 전력을 실시간으로 분석하여 LCD와 D/A변환기로 출력하였다. 2PH의 모터와 그 구동장치(인버터)의 전력품질을 분석함으로서 외국산 제품과 비교하여 그 성능과 정밀도 등을 검토하였다. 개발된 시스템은 종전의 대전력용 전력분석장비에 비해 사용하기 쉽고, 설치공간과 가격이 크게 감소되며 저전력의 전력품질 분석에 적합한 시스템입을 확인하였다.

  • PDF

고조파전류 측정에 근거한 국내 고조파 관리기준 검토 (Examination of the domestic harmonic standard introduction based on measurement of harmonic current)

  • 박용업;강문호;이남우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.539-540
    • /
    • 2007
  • In order to increase an efficiency of electric machine, the power electric devices are rapidly increasing of late. These electric components are mainly caused to lower of power quality. To take precautions against lower of power quality, the advanced countries already made effort to control of harmonic level. For these harmonic control of advanced countries have applied harmonic planning level, emission of harmonic based on the technical calculation and experiment. In this paper, we have investigated the introduction abroad advanced country standard through compared IEEE, IEC with the real measurement of domestic harmonic level.

  • PDF

모터 구동장치를 위한 DSP기반 3상 전력품질분석 시스템 (A DSP based Three Phase Power Quality Analyzer for Motor Drives)

  • 김우용;정영국;임영철
    • 전력전자학회논문지
    • /
    • 제6권1호
    • /
    • pp.27-33
    • /
    • 2001
  • 본 연구에서는 독립형 TMS32OC31 DSP보드에 의해 전략분석 과정을 완전 소프트웨어화하고, 전압센서와 전류 센서를 시스템 내부에 탑재한 저전력용 3상 모터구동장치플 위한 전랙품질 분석시스템을 개발하였다. 평균전력이 론에 의해 전략품질을 분석하였고 분석 결과를 LCD화변에 의해서 실시간으로 출력하였다. 특히 개발된 시스템은 설치공간이 필요한 종전의 대전력용 전력분석장비와는 다르게, 상용 인버터에 곧바로 탑재 가능하도록 히여 설치 공간을 줄였고 또한 초보자도 사용하기 용이하게 하였다. 정상상태와 모터구동장치의 부하가 급변하는 과도상태에 서도 제안된 전력품질 분석시스템은 실시간으로 전력분석을 하였으며, 본 연구의 유용성을 엽증할 수 있었다.

  • PDF