A Torque Ripple Reduction System of Induction Motor with Direct Torque Control (직접 토크제어에 의한 유도전동기 토크맥동 저감 시스템)

  • Kim Nam-Hun;Kim Min-Ho;Kim Min-Huei;Kim Dong-Hee;Hwang Don-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.276-279
    • /
    • 2001
  • Direct torque control(DTC) is known to produce quick response in ac drives. Some drawbacks of the classical DTC are the relatively large torque ripple in a low speed range and notable current pulsation during steady state. They are reflected speed response and increased acoustical noise. In this paper, The DTC quick response are preserved at transient state, while better qualify steady state performance is produced by Space Vector Modulation(SVM). It is able to reduce the acoustical noise, torque ripple and current pulsation during steady state. The system presented are closed loop stator flux and torque observer for wide speed range that inputs are currents and voltages sensing of motor terminal. Simulation results for the 2.2kw general purposed induction motor are presented and discussed.

  • PDF

The Study of the Design of a Hydraulic Torque Load Simulator Equipped with a Direct Drive Servo Valve and a Feed forward Compensator (직접 구동형 서보밸브와 전진 보상기를 적용한 유압식 토크 부하 시뮬레이터의 설계에 관한 연구)

  • Lee, Seong Rae
    • Journal of Drive and Control
    • /
    • v.15 no.1
    • /
    • pp.16-27
    • /
    • 2018
  • Hydraulic torque load simulator is essential to test and qualify the performance of various angle control systems. Typically a flapper-type second stage servovalve is applied to the load simulator, but here the direct drive servovalve, which is a kind of one-stage valve and affected by the large flow force, is applied. Since the torque load is applied not to the stationary shaft but to the rotating shaft of the angle control system, the controlled torque of load simulator is not accurate due to the rotating speed of the angle control system. A feedforward compensator is designed and applied to minimize the disturbance-like effect. A mathematical model is derived and linearized to analyze the stability, accuracy and responsiveness of the torque load simulator. The parameter effects of a controller, servovalve, hydraulic motor, rotating spring shaft are analyzed and summarized. The goodness of the linear analysis is verified by the digital computer simulations using both the linear and nonlinear mathematical models.

Evaluation and Performance Test of Ball and Socet type Suspension Insulator for 300 kN Ultra High Voltage (300kN 초고압용 초고압용 볼소켓형 현수애자의 성능평가)

  • Kim, S.S.;Kim, K.U.;Her, J.C.;Cho, H.G.;Park, T.G.;Seo, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2026-2028
    • /
    • 2000
  • As the results of evaluation of its performance for 300 kN Ball and Socket type suspension insulators. There was electrically internal puncture of the solid insulating body of the insulating due to the steep front impulse voltage, which usually occurs puncture before external flash-over of insulators, moreover we have obtained satisfactory results in power arc test of 7.2kA cycle fatigue test with high qualify control index of 4.6, especially we have obtained more satisfactory results than that before improvement of its materials.

  • PDF

Characteristic of a Superconducting Magnet for 3MJ SMES (3MJ SMES용 초전도 마그네트 특성연구)

  • 김해종;성기철;조전욱;배준한;심기덕;류경우;김상현
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.246-249
    • /
    • 2003
  • For quite a long time various researches and developments of superconducting magnetic energy storage(SMES) device for enhancement of power qualify control of sensitive electric load. This paper describes the design, fabrication and experimental results for the 3MJ SMES magnet made by using the design code of a SMES device that we developed. A computer code was developed to find the parameters of the SMES magnet which has minimum amount of superconductor for the same stored energy, and the 3MJ SMES magnet was designed based upon that. And 3MJ SMES magnet made base of several research result which was ramp up to 1㎄ without quench.

  • PDF

Construction of Ultrasonic Power Measurement System and Its Performance Evaluation (초음파 파워 측정 시스템 구성 및 성능평가)

  • Jho Moon Jae;Kim Yong Tae;Yun Yong Hyeon;Jung Suug Soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.8
    • /
    • pp.431-440
    • /
    • 2005
  • The precise measurement of ultrasonic power is important to the qualify assurance and the safety of medical ultrasonic equipments In the Present work, a brier theory was introduced to determine the ultrasonic Power from the time valving balance-indication due to the radiation force acting on an absorbing target and/or other causes such as buoyancy during the repetition of on/off behavior of ultrasonic irradiation. The developed automated system measuring the ultrasonic power was described in detail with the precise mechanical alignment tool , the electric signal generation network, the control and measurement network and the appropriate procedure. The ultrasonic power measured by the developed system was compared to the reference data calibrated by the other national metrology institute at 1 MHz, 5 MHz, 10 MHz, and 15 MHz over the range 10 mW to 10 W. Their relative differences are within $5\%$.

The study on temperature distribution characteristic of irradiated surface by CO2 laser (온도센서를 이용한 CO2레이저 빔 조사면의 온도 분포 특성에 관한 연구)

  • Min, Byoung-Dae;Kim, Tae-Kyun;Chung, Hyun-Ju;Kim, Yong-Cheol;Joung, Jong-Han;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1831-1833
    • /
    • 2003
  • Nowadays, CO2 lasers are used widely in many applications such as materials fabrication, communications, remote sensing and military purpose etc. Especially, CO2 lasers are in the spotlight at surface handling and heat processing. It is important to control the laser output power and beam quality in those fields. To increase beam qualify, We used the feedback system by various sensors. Although, CO2 lasers' output beam became feedback, its beam affected the irradiated material target already. Since, ideal real time control have still the problem to solve. Hence, we need the new proposal for more precise laser processing. So we expect the new effect how to change the irradiated material target as the kind of, processing time and output density caused by the CO2 laser beam. In this study, We have investigated the characteristics of the temperature and HAZ(Heat Affected Zone) by CO2 laser output with IR temperature sensor and RTD.

  • PDF

Design and Fabrication of a X-band Voltage Control Dielectric Resonator Oscillator with The Low Phase Noise (낮은 위상잡음을 갖는 X-band 전압제어 유전체 공진형 발진기의 설계 및 제작)

  • 박창현;최병하
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.5
    • /
    • pp.69-76
    • /
    • 2004
  • In this paper, a VCDRO (Voltage Control Dielectric Resonator Oscillator) with low phase noise for X-band application has been designed and fabricated. A low noise and low flicker noise MESFET and a high Q dielectric resonator were selected to obtain good phase noise Performance. Also, a varactor diode having high Q, qualify factor was used to reduce the loading effects and a big Gamma of diode was chosen for linearity of frequency over voltage tuning range. The fabricated circuits was simulated with circuit design tools, ADS to provide the optimum performances. As the measured results of fabricated oscillator, the output power was 5.8 ㏈m at center frequency 12.05㎓ and harmonic suppression -30㏈c, phase noise -114 ㏈c at 100 KHz offset frequency, respectively, and the frequency tuning range as the function of valtage applied to varactor diode was 15.2 MHz and its power variation with frequency was 0.2 ㏈. This oscillator could be available to a local oscillator in X-band.

Design of Voltage Controlled Oscillator with High Reliability and Low Phase Noise (고신뢰성과 저위상잡음을 갖는 전압제어 발진기의 설계 및 제작)

  • Ryu Keun-Kwan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.3 no.1 s.4
    • /
    • pp.13-19
    • /
    • 2004
  • The VCO(Voltage Controlled Oscillator) with low phase noise and high reliability is implemented using nonlinear design, and its phase noise characteristics are compared with that of Lesson's equation. The microstripline coupled with dielectric resonator is realized as a high impedance inverter to improve the phase noise, and the qualify factor of resonator circuit can be transferred to active device with the enhanced the loaded quality factor. The worst case and part stress analyses are achieved to obtain the high reliability of VCO. The developed VCO has the oscillating tuning factor of 0.56MHz/V for the control voltage range of 0$\~$12V This VCO requires the DC power of 160mW. The phase noise characteristics exhibit good performances of -96.51dBc/Hz @ 10KHz and -116.3dBc/Hz @ 100KHz, respectively. And, the output power of 7.33 dBm is measured.

  • PDF

IRRADIATION DEVICE FOR IRRADIATION TESTING OF COATED PARTICLE FUEL AT HANARO

  • Kim, Bong Goo;Park, Sung Jae;Hong, Sung Taek;Lee, Byung Chul;Jeong, Kyung-Chai;Kim, Yeon-Ku;Kim, Woong Ki;Lee, Young Woo;Cho, Moon Sung;Kim, Yong Wan
    • Nuclear Engineering and Technology
    • /
    • v.45 no.7
    • /
    • pp.941-950
    • /
    • 2013
  • The Korean Nuclear-Hydrogen Technology Development (NHTD) Plan will be performing irradiation testing of coated particle fuel at HANARO to support the development of VHTR in Korea. This testing will be carried out to demonstrate and qualify TRISO-coated particle fuel for use in VHTR. The testing will be irradiated in an inert gas atmosphere without on-line temperature monitoring and control combined with on-line fission product monitoring of the sweep gas. The irradiation device contains two test rods, one has nine fuel compacts and the other five compacts and eight graphite specimens. Each compact contains about 260 TRISO-coated particles. The irradiation device is being loaded and irradiated into the OR5 hole of the in HANARO core from August 2013. The device will be operated for about 150 effective full-power days at a peak temperature of about $1030^{\circ}C$ in BOC (Beginning of Cycle) during irradiation testing. After a peak burn-up of about 4 atomic percentage and a peak fast neutron fluence of about $1.7{\times}10^{21}\;n/cm^2$, PIE (Post-Irradiation Examination) of the irradiated coated particle fuel will be performed at IMEF (Irradiated Material Examination Facility). This paper reviews the design of test rod and irradiation device for coated particle fuel, and discusses the technical results for irradiation testing at HANARO.